19.142.140 Specific standards.
The following provisions are required in all areas of special flood hazards where base flood elevation data has been provided as set forth in FWRC 19.142.050(1) or 19.142.070. (1) Residential construction in zone AE. (a) New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated one foot or more above the base flood elevation (BFE). (b) Fully enclosed areas below the lowest floor that are subject to flooding are prohibited, or if used solely for parking, access or storage, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: (i) A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. (ii) The bottom of all openings shall be no higher than one foot above grade. (iii) Openings may be equipped with screens, louvers, or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters. Foundation vent standards required by the IBC/IRC outside the floodplain do not meet this standard and are often inadvertently permitted. Insurance rates reflect an “all or nothing” standard. Partially ventilated crawlspaces may be subject to an additional loading fee of 20 to 25 percent attached to the annual insurance premium. Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the director for verification. (2) Residential construction in zone VE. (a) Be located landward of the reach of mean high tide; (b) Have the bottom of the lowest structural member of the lowest floor (excluding pilings and columns), elevated to or above the base flood elevation; (c) Have the pile or column foundation and structure attached thereto be anchored to resist flotation, collapse and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those required by applicable state or local building standards; (d) Have the space below the lowest floor, usable solely for parking of vehicles, building access, or storage, either free of obstruction or constructed with nonsupporting breakaway walls, open wood lattice-work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purposes of this section, a breakaway wall shall have a design safe loading resistance of not less than 10 and no more than 20 pounds per square foot; (e) Prohibit the use of fill for structural support of buildings; and (f) Prohibit manmade alteration of sand dunes and mangrove stands. A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of this section. Upon completion of construction, certification by a registered professional engineer or architect that these design standards have been satisfied, and certification by a registered professional engineer or surveyor that the elevation requirements of the bottom of the lowest structural member of the lowest floor, excluding pilings and columns, of this section have been satisfied shall be provided to the director for verification. (3) Nonresidential construction in an AE zone. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement, elevated one foot or more above the base flood elevation; or, together with attendant utility and sanitary facilities, shall: (a) Be floodproofed so that below one foot or more above the base flood level the structure is watertight with walls substantially impermeable to the passage of water; (b) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; (c) Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection based on their development and/or review of the structural design, specifications and plans. Such certifications shall be provided to the official as set forth in FWRC 19.142.060(2); (d) Nonresidential structures that are elevated, not floodproofed, must meet the same standards for space below the lowest floor as described in subsection (1)(b) of this section. Applicants who are floodproofing nonresidential buildings should beware that flood insurance premiums will be based on rates that are one foot below the floodproofed level (e.g., a building floodproofed to the base flood level will be rated as one foot below). Floodproofing the building an additional foot will reduce insurance premiums significantly. Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the director for verification; or certification by a registered professional engineer or architect that the floodproofing design of this section is satisfied, including the specific elevation in relation to mean sea level to which such structures are floodproofed, shall be provided to the director for verification. (4) Nonresidential construction in zone VE. Floodproofing of nonresidential structures is prohibited. All structures must be elevated and constructed according to the requirements set forth in FWRC 19.142.140(1). (5) Manufactured homes in zone AE. All manufactured homes to be placed or substantially improved on sites shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated one foot or more above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. Upon completion of installation of the manufactured home, certification by a registered professional engineer or surveyor that the elevation requirements of this section have been satisfied shall be provided to the director for verification. (6) All manufactured homes to be placed or substantially improved on sites shall meet the standards of residential construction in VE zones in FWRC 19.142.140(1). Upon completion of installation of the manufactured home, certification by a registered professional engineer or surveyor that the elevation requirements of this section have been satisfied shall be provided to the director for verification. (7) Recreational vehicles. Recreational vehicles placed on sites are required to either: (a) Be on the site for fewer than 180 consecutive days; or (b) Be fully licensed and ready for highway use, on wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached additions; or (c) Meet the requirements of subsection (3) of this section and the elevation and anchoring requirements for manufactured homes.
(Ord. No. 20-893, § 11, 8-11-20; Ord. No. 06-536, § 2(Exh. A), 11-7-06. Code 2001 § 21-113. Formerly 16.40.140.)
Ask a question about Federal Way law
Corpus searches the Federal Way sections it holds and shows the ones that match, with their citations. Free, no sign-in.