All single-section or multiple-section mobile homes must be anchored when the Building Inspector determines that the pier-blocking height to be a safety hazard, or where the wind velocities in the area are dangerous. Any required anchoring must be as specified by the manufacturer. Where the manufacturer's anchoring recommendations are not available, the anchoring must be in accord with the following: (1) Components of the anchoring system must have a resistance to weather deterioration that is at least equivalent to that of a zinc coating that is not less than 0.3 ounces per square foot of coated surface. Cut edges of zinc-coated strapping do not need to be coated. (2) An installer must install, preload, and adjust a ground anchor in accord with the anchor manufacturer's instructions. The installer must supply a copy of the instructions to the City, as appropriate. A ground anchor, when installed, must be able to resist a working load of 3,150 pounds in the direction of the tie plus a 50-percent overload (4,725 pounds total) without failure. Failure occurs if the point of connection of a vertical tie to an anchor is withdrawn more than two inches at 3,150 pounds, or when the point of connection of a diagonal tie is moved more than four inches horizontally when a load of 3,150 pounds is applied at 45 degrees from the horizontal. Ground anchors must be marked with the manufacturer's identification and model number in a location that is visible after the anchor is installed. The manufacturer of a ground anchor must provide instructions with each anchor that specify the kinds of soil for which the anchor is suitable. (3) If concrete slabs or continuous footings are used to transfer the anchoring loads to the ground, the following requirements apply: (a) Steel rods cast in concrete must be able to resist the loads and corrosion as specified for ground anchors. (b) A deadman anchor may be used in place of a listed anchor. It must be constructed of solid concrete at least six inches in diameter and two feet long, reinforced with two #4 deformed steel rods, and installed at least five feet below the surface of the ground. (c) A concrete slab may be used in place of a ground anchor if it provides holding strength equal to that required for ground anchors. (4) Ties must be of cable, strapping, or other approved materials. Ties must be fastened to ground anchors and drawn tight with turnbuckles, yoke fasteners, or other approved tensioning devices. Tension devices must end in clevis, forged, or welded eyes. Hook ends are not permitted. Tension devices must be designed to prevent self-disconnection if the tie becomes slack. Cable tie eyes must be secured with two U-bolt cable clamps or an approved equivalent. Tie materials must be able to resist a working load of 3,150 pounds with no more than 2 percent elongation and withstand a 50-percent overload (4,725 pounds total). Ties must connect the ground anchor to the main frame longitudinal member. Ties may not connect to steel outrigger beams that fasten to the main frame, unless the manufacturer's installation instructions specifically approve the connection. Diagonal ties must lie at least 40 degrees from the vertical. Vertical ties must be substantially vertical. If a vertical tie is not substantially vertical, the anchor must be placed outboard of the tie's connection to the main frame. A cable frame tie must be connected to the main frame by a five-eighths-inch drop, forged, closed-eye bolt through a hole drilled in the center of the I-beam web, or by an approved alternative. The installer must reinforce the web if necessary to maintain the strength of the I-beam. The installer must space the ties as evenly as practical, and must locate a tie within eight feet of each end of the mobile home. The installer may attach two or more ties to a single ground anchor if the anchor can carry the total required load. The installer must install vertical ties at each detached corner of a clerestory roof and of add-on sections of expandable mobile homes. As a minimum, the installer must install the following number of ties for each I-beam or other main frame longitudinal member: Length of Home (Feet) Excluding Hitch | Number of Vertical Ties | Number of Diagonal Ties 32-54 | 2 | 3 55-73 | 2 | 4 Multiple section mobile homes require only diagonal ties. Vertical ties are not required.
(Ord. 2740 Sec. 1(part), 1983)
Ask a question about Kennewick law
Corpus searches the Kennewick sections it holds and shows the ones that match, with their citations. Free, no sign-in.