For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.66.060 — Standards for Flood Hazard Reduction

Code of Ordinances of the City of Kennewick, Washington (Codified through Ordinance No. 26-6253, enacted September 15, 2026 (Supp. No. 19)) · Kennewick Municipal Code § 18.66.060

Corpus is an independent public-information project, not the official City of Kennewick website. Stable reference: corpuslaw.us/code/186e104b-aab7-4025-8c2d-8b72e38b6df3

18.66.060: - Standards for Flood Hazard Reduction.

(1) General Standards. In all areas of special flood hazards the following standards apply: (a) Anchoring. (i) All new construction and substantial improvements must be anchored to prevent flotation, collapse, or lateral movement. (ii) All manufactured homes must be anchored to prevent flotation, collapse, or lateral movement by providing the over-the-top and frame ties to ground anchors. Over-the-top ties must be provided at each of the four corners of the mobile home with two additional ties per side at intermediate locations, but mobile homes less than 50 feet long need have only one additional tie per side. Frame ties must be provided at each corner of the home with five additional ties per side. All components of the anchoring system must be capable of carrying a force of 4,800 pounds. Any additions to the mobile home must be similarly anchored. (iii) An alternative method of anchoring may be used provided it complies with the standards contained in FEMA's "Manufactured Home Installation in Flood Hazard Areas" guidebook; incorporated herein by reference. (b) Construction Materials and Methods. All new construction and substantial improvements must be constructed with materials and utility equipment and by methods and practices that resist and minimize flood damage. (c) Mechanical Equipment and Utilities. (i) Electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities shall be designed and/or otherwise elevated or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (ii) All new and replacement water supply systems must be designed to eliminate or minimize the infiltration of floodwaters into the system; (iii) All new and replacement sanitary sewage systems must be designed to minimize or eliminate infiltration from and discharge into floodwaters; (iv) On-site waste disposal systems must be located and designed to avoid impairment or contamination during flooding; and (v) Water wells shall be located on high ground that is not in the floodway. (d) Subdivision Proposals. (i) All subdivision proposals shall be consistent with the need to minimize flood damage; (ii) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems, located and constructed to minimize or eliminate flood damage; (iii) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood damage; (iv) Base flood elevation data must be provided for subdivision proposals and other proposed developments which contain at least 50 lots or five acres (whichever is less). (e) Review of Building Permits. The Planning Director shall obtain, review and reasonably utilize the best available information as criteria for requiring that new construction, substantial improvements, or other development in Zone "A" conform to applicable provisions of this Chapter. Where elevation data is not available either through the Flood Insurance Study or from another authoritative source (Section 18.66.040(4)(c)), applications for building permits shall be reviewed to assure that proposed construction will be reasonably safe from flooding. The test of reasonableness is a local judgment and includes use of historical data, high water marks, photographs of past flooding, etc., where available. Residential and commercial structures in unnumbered "A" Flood Hazard Zones must be elevated with their lowest floor at least two feet above grade. Failure to elevate at least two feet above grade in unnumbered "A" Zones may result in higher insurance rates. All applicants for building permits within special flood hazard areas are encouraged to elevate the lowest floor at least one foot above the base flood level. Elevating to at least one foot above the base flood will further substantially reduce the damage potential in the event of a 100-year flood; and, will have a lessening effect on the fees or rates for required flood insurance. (2) Specific Standards. In all areas of special flood hazards where base flood elevation data has been provided, as set forth in Section 18.66.030(2) or 18.66.040(4)(d), the following standards apply: (a) Residential Construction. (i) New Construction and substantial improvement of any residential structure must have the lowest floor, including basement, elevated one foot above the base flood elevation. Fully enclosed areas below the lowest floor that are subject to flooding are prohibited, or shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must be certified by a registered professional engineer or must meet or exceed the following minimum criteria: A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided; the bottom of all openings shall be no higher than one foot above grade; and openings may be equipped with screens, louvers, or other coverings or devices, provided that they permit automatic entry and exit of floodwaters. (ii) Manufactured Homes. All manufactured homes to be placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM on sites: Outside of a manufactured home park or subdivision in an expansion to an existing manufactured home park or subdivision, in a new manufactured home park or subdivision, or in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated one foot above the base flood elevation and be securely anchored to an adequately designed foundation system to resist flotation collapse and lateral movement. Manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision with A1-30, AH, and AE on the community's FIRM that are not subject to the above manufactured home provisions be elevated so that either: the lowest floor of the manufactured home is elevated one foot above the base flood elevation, or the manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately designed foundation system to resist flotation, collapse, and lateral movement. (iii) Residential structures that contain fully enclosed areas below the base flood level must meet the same standards for such areas as described in Section 18.66.060(2)(b)(i). (b) Nonresidential Construction. New construction and substantial improvement of any commercial, industrial or other nonresidential structure must either have the lowest floor, including basement, and attendant utility and sanitary facilities, elevated one foot above the base flood elevation; or floodproofed so that below one foot above the base flood level the structure is watertight with walls substantially impermeable to the passage of water, has structural components capable of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy, be certified by a registered professional engineer that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection based on their development and/or review of the structural design, specifications, and plans. Such certifications shall be provided to the official as set forth in Section 18.66.040(2). (i) Nonresidential structures that are elevated, not floodproofed, must meet the same standards for space below the lowest floor as described in Section 18.66.060(2)(a)(i). (ii) Applicants floodproofing nonresidential buildings shall be notified that flood insurance premiums will be based on rates that are one foot below the floodproofed level (a building floodproofed to the base flood level will be rated as one foot below that level). (c) Floodways. Located within areas of special flood hazard established in Section 18.66.030(2) are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters that can carry debris, and increase erosion potential, the following provision apply: (i) Encroachments are prohibited, including fill, new construction, substantial improvements and other development; unless certification by a registered, professional civil engineer is provided demonstrating through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachments will not increase flood levels during the occurrence of the base flood discharge. (ii) Construction or reconstruction of residential structures is prohibited within designated floodways except for (1) repairs, reconstruction, or improvements to a structure which do not increase the ground flood area; and (2) repairs, reconstruction or improvements to a structure, the cost of which does not exceed 50 percent of the market value of the structure either before the repair, or reconstruction is started, or if the structure has been damaged and is being restored, before the damaged occurred. Any project for improvement of a structure to correct existing violations of state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions, or to structures identified as historic places, may be excluded in the 50 percent. (iii) If Subsection (c)(i) is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section. (d) Standards for Shallow Flooding Areas (AO Zones). Shallow flooding areas appear on Flood Insurance Rate Maps as AO zones with depth designations. The base flood depths in these zones range from one to three feet above ground where a clearly defined channel does not exist, or where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is usually characterized as sheet flow. In these areas, the following provisions apply: (i) New construction and substantial improvements of residential structures and manufactured homes within AO zones shall have the lowest floor (including basement) elevated above the highest grade adjacent to the building, one foot or more above the depth number specified on the FIRM (at least two feet above the highest adjacent grade to the structure if no depth number is specified). (ii) New construction and substantial improvements of nonresidential structures within AO zones shall either: (A) Have the lowest floor (including basement) elevated above the highest adjacent grade of the building site, one foot or more above the depth number specified on the FIRM (at least two feet if no depth number is specified); or (B) Together with attendant utility and sanitary facilities, be completely floodproofed to or above that level so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. If this method is used, compliance shall be certified by a registered professional engineer. (iii) Require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. (iv) Recreational Vehicles. Recreational vehicles placed on sites within Zones A, AO, A1-30, and AE in the community's FIRM either must: Be on site for fewer than 180 consecutive days, or be fully licensed and ready for highway use, be on its wheels or jacking system, be attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached additions; or meet the requirements of Section 18.66.060(2)(a)(ii) and the elevation and anchoring requirements for manufactured homes. (e) Critical Facilities. Construction of new critical facilities shall be, to the extent possible, located outside the limits of the Special Flood Hazard Area (SFHA) (100-year floodplain). Construction of new critical facilities shall be permissible within the SFHA if no feasible alternative site is available. Critical facilities constructed within the SFHA shall have the lowest floor elevated three feet or more above the level of the base flood elevation (100-year) at the site or to the height of the 500-year event, whichever is higher. Access to and from the critical facility should also be protected to the height utilized above. Floodproofing and sealing measures must be taken to ensure that toxic substances will not be displaced by or released into floodwaters. Ingress and egress routs, elevated to or above the base flood elevation, shall be provided to all critical facilities to the extent possible. (f) Encroachments. In areas with base flood elevations (but a regulatory floodway has not been designated), no new construction, substantial improvements, or other development (including fill) shall be permitted within Zones A1-30 and AE on the community's FIRM, unless it is demonstrated that the cumulative effect of any proposed development, where combined with all other existing and anticipated development, shall not increase the water surface elevation of the base flood more than one foot at any point.

(Ord. 5824 Sec. 4, 2019; Ord. 5309 Sec. 20, 2010; Ord. 5180 Sec. 1, 2007)

Ask a question about Kennewick law

Corpus searches the Kennewick sections it holds and shows the ones that match, with their citations. Free, no sign-in.