§ 14.09.130 — Specific standards

Kent City Code (current through Ordinance 4547, passed August 18, 2026) · Kent City Code § 14.09.130

Corpus is an independent public-information project, not the official City of Kent website. Stable reference: corpuslaw.us/code/b4239b72-6413-42c8-85ee-7c64b248829c

14.09.130 Specific standards.

In all special flood hazard areas identified in KCC 14.09.050, the following provisions are required: A. Residential construction. 1. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to the flood protection elevation. 2. Fully enclosed areas below the lowest floor usable solely for parking, access or storage and that are subject to flooding are prohibited, or shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: a. A minimum of two openings placed on at least two separate walls and having a total net area of not less than one square inch for every square foot of enclosed areas subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one foot above grade. c. Openings may be equipped with screens, louvers, or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters. B. Nonresidential construction. New construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall either have the lowest floor, including basement, elevated to the flood protection elevation; or, together with attendant utility and sanitary facilities, shall: 1. Be floodproofed to the flood protection elevation so that the structure is watertight with walls substantially impermeable to the passage of water; 2. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; 3. Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection based on their development and/or review of the structural design, specifications, and plans. Such certifications shall be provided to the director; 4. Nonresidential structures that are elevated, not floodproofed, must meet the same standards for space below the lowest floor as described in subsection (A)(2) of this section; 5. Applicants floodproofing nonresidential buildings shall be notified that flood insurance premiums will be based on rates that are one foot below the floodproofed level (e.g., a building floodproofed to one foot above the base flood level will be rated as at the base flood level). C. Critical facility. Construction of new critical facilities shall be, to the extent possible, located outside the limits of the floodplain. Construction of new critical facilities shall be permissible within the floodplain if no feasible alternative site is available. Critical facilities constructed within the floodplain shall have the lowest floor elevated to three feet or more above the level of the base flood elevation at the site. Below the lowest floor, floodproofing and sealing measures must be taken to ensure that toxic substances will not be displaced by or released into floodwaters. Access routes elevated to or above the level of the base flood elevation shall be provided to all critical facilities to the extent possible. D. Manufactured homes. All manufactured homes to be placed or substantially improved within zones AH and AE on the community’s FIRM shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is at the flood protection elevation; and be securely anchored to an adequately anchored foundation system in accordance with KCC 14.09.120(A)(2). Openings in accordance with subsection (A) of this section are required in rigid skirting attached to frames or foundations of manufactured homes to relieve hydrostatic loads and minimize transferring loads that can damage homes and their supporting foundation systems. Installation of skirting does not trigger the requirement for flood openings if the skirting does not provide structural support and will collapse, without causing structural damage to the elevated home or the foundation, under wind and water loads that are less than those expected during the base flood event. E. Recreational vehicles. Recreational vehicles placed on sites are required to meet all applicable provisions of this code. If allowed by code, recreational vehicles are required to either: 1. Be onsite for fewer than 180 days; 2. Be fully licensed and ready for highway use, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached additions; or 3. Meet the requirements of KCC 14.09.120(A) and the elevation and anchoring requirements for manufactured homes. F. Drainage around structures. Adequate drainage paths are required around structures on slopes to guide waters around and away from proposed structures. G. Standards for AE zones with base flood elevations but no floodways. In areas with base flood elevations, if a regulatory floodway has not been designated, no new construction, substantial improvements, or other development, including fill, shall be permitted within zone AE on the community’s FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community. H. Below-grade crawlspace. 1. The interior grade of a crawlspace must not be below the base flood elevation and must not be more than two feet below the exterior lowest adjacent grade. 2. The height of the below-grade crawlspace, measured from the interior grade of the crawlspace to the top of the crawlspace foundation wall, must not exceed four feet at any point. 3. Flood openings are required and must meet the requirements of subsection (A)(2) of this section. 4. There must be an adequate drainage system that removes floodwaters from the interior area of the crawlspace. The enclosed area should be drained within a reasonable time after a flood event. 5. The velocity of floodwaters at the site should not exceed five feet per second for any crawlspace.

(Ord. No. 4361, § 2, 7-7-20) | Prior legislation – Ords. 2282, 2867, 3228, 3232, 3746, 3880, 3909, 4158 and 4218; formerly Code 1986, §§ 14.22.010, 14.22.020, 14.22.030, 14.22.040 – 14.22.062, 14.22.090, 14.22.120, 14.22.130 and 14.22.160.

Ask a question about Kent law

Corpus searches the Kent sections it holds and shows the ones that match, with their citations. Free, no sign-in.