For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.16.040 — General requirements

Kent City Code (current through Ordinance 4547, passed August 18, 2026) · Kent City Code § 6.16.040

Corpus is an independent public-information project, not the official City of Kent website. Stable reference: corpuslaw.us/code/d0663dfd-0405-4099-b8e4-2bf5f14292c6

6.16.040 General requirements.

A. All utility and light poles, wireless facilities, and small wireless facilities shall be constructed or installed according to applicable federal, state, and city regulations and standards, including the City of Kent Design and Construction Standards. B. Ground-mounted equipment in the right-of-way is prohibited, unless such equipment is placed underground or is otherwise approved by the director. C. Small wireless facilities are not permitted on traffic control signal systems. D. Small wireless facilities are not permitted in residential zoning districts outside of the right-of-way, except in public parks and on public school campuses, set back 30 feet away from property lines. Small wireless facilities may only be installed outside of the right-of-way in residential zoning districts in the locations listed in this subsection with express permission from the property owner and according to the land use permit process outlined in KCC 15.04.060 and 15.08.035. E. All poles shall comply with the Americans with Disabilities Act (“ADA”), City of Kent Design and Construction Standards, and state and federal regulations in order to provide clear passage within the rights-of-way. The location of any replacement or new utility pole, or combination pole must not interfere with utility or safety fixtures (e.g., fire hydrants, traffic control devices), not interfere with sight distance, and not adversely affect public health, safety, or welfare. F. In order to minimize negative visual impact to the surrounding area and to avoid excessive overhead clutter, the director may deny a request for proposed wireless facilities or small wireless facilities where the proposed location is deemed inappropriate due to the extent of existing aboveground wireless telecommunications or other electrical or cable facilities existing within a 150-foot radius of the proposed wireless facility or small wireless facility location. The director may also deny a request for proposed wireless facilities on a utility pole already containing more than one electrical transformer. G. The use of any city-owned infrastructure, other streetlight standard, or utility pole for the siting of small wireless facilities within the right-of-way shall be considered secondary to the primary function of the pole. If the primary function of a pole serving as the host for small wireless facilities becomes unnecessary, the pole shall not be retained for the sole purpose of accommodating the small wireless facilities, and the small wireless facilities, including all associated equipment, shall be removed. H. Replacement utility poles are subject to the following requirements: 1. All replacement utility poles (with or without small wireless facilities or other wireless facilities) shall be located as near as possible to the existing utility pole, while meeting the current City of Kent Design and Construction Standards. The abandoned utility pole must promptly be removed. 2. Proposed replacement utility poles, for the purpose of siting wireless facilities other than small wireless facilities, shall be no more than 20 feet taller than adjacent utility poles, unless an additional height increase is required for vertical separation and such height extension is the minimum extension possible to provide sufficient separation and/or clearance from electrical and wireline facilities. The replacement utility pole shall be of similar shape, color, and material to the original utility pole. Any wireless facility equipment mounted on a replacement utility pole shall also comply with the color, mounting, illumination and concealment of wires requirements set forth in KCC 6.16.050(C)(1) through (4). I. Replacement and combination poles shall match or be similar to the color and material of the original or adjacent poles. Replacement and combination poles shall be located in a location that minimizes the appearance from existing adjacent residential structures to the maximum extent feasible. For example, locations where new poles or replacement poles would be close to windows, in front of historically or architecturally significant buildings, or in locations where the equipment would disturb views of significance should be avoided. J. The number of conduits shall be minimized to the number necessary to accommodate the facilities or equipment on the utility pole. The color of external cables, wires, and conduits shall match or be similar to the color of the utility pole or be a neutral color such as black, brown, beige, off-white, or light gray. The conduit shall be mounted as closely as possible to the pole, while still meeting the required safety clearances. K. All cables and wiring on utility poles shall also be concealed to the maximum extent feasible. Any wires outside the conduit shall be consolidated and pulled as tight as technically feasible. Loops of excess wires shall not be lashed to the pole, to electrical wires supported by the pole, or to any pole-mounted equipment. L. Ancillary equipment and facilities, including conduit and cable, shall not dominate the structure or utility pole upon which these things are attached. M. Antennas and related equipment shall not be illuminated except for security reasons, required by a federal or state authority, or unless approved as part of a concealment element plan. N. The city may consider the cumulative visual effects of small wireless facilities mounted on poles within the rights-of-way when assessing proposed siting locations so as not to adversely affect the visual character of the area. This provision shall neither be applied to limit the number of permits issued when no alternative sites are reasonably available nor to impose a technological requirement on the service provider. O. These design standards are intended to be used solely for the purpose of concealment and siting. Nothing herein shall be interpreted or applied in a manner which dictates the use of a particular technology. When strict application of these requirements would unreasonably impair the function of the technology chosen by the applicant, alternative forms of concealment or deployment may be permitted which provide similar or greater protections from negative visual impacts to the streetscape. P. No equipment on any utility or combination pole may be operated so as to produce noise in violation of the applicable noise standards set forth in Chapter 8.05 KCC.

(Ord. No. 4318, § 1, 4-2-19; Ord. No. 4409, § 2, 8-17-21)

Ask a question about Kent law

Corpus searches the Kent sections it holds and shows the ones that match, with their citations. Free, no sign-in.