§ 7.04.180 — Use of public sanitary sewer
Kent City Code (current through Ordinance 4547, passed August 18, 2026) · Kent City Code § 7.04.180
Corpus is an independent public-information project, not the official City of Kent website. Stable reference: corpuslaw.us/code/92e57b56-052a-4c27-a17e-87b8a1c77e2b
7.04.180 Use of public sanitary sewer.
A. Discharge of storm or surface water to sanitary sewer system – Prohibited. No person shall discharge or cause to be discharged any stormwater, surface water, groundwater, or roof runoff, to the sanitary sewer system, unless expressly authorized by the director. B. Prohibited discharges to sanitary sewer system. Except as otherwise provided in this chapter, no person shall discharge or cause to be discharged any of the following described substances to the sanitary sewer system: 1. Any liquid or vapor having a temperature higher than 150 degrees Fahrenheit; 2. Any water or waste that may contain more than 100 parts per million by weight of FOG; 3. Any gasoline, benzene, naphtha, fuel oil, or other flammable or explosive liquid, solid, or gas; 4. Any emulsifying agent, enzyme, bio-additive, or similar chemical; 5. Any animal guts or tissue, paunch manure, bones, hair, hides or fleshings, entrails, fish guts or skin, seafood shells, cloth, carpet fibers, plastic, ashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, grass clippings, brewing or distilling slops, spent grain or hops, lard, tallow, baking dough, coffee grounds, tea leaves or any other solid or viscous substance capable of causing obstruction to the flow in sewers or other interference with the proper operation of the sewage works; 6. Any waters or wastes having a pH lower than 5.5 or higher than 9.0 or having any corrosive property capable of causing damage or hazard to structures, equipment, and personnel of the sewage works; 7. Any waters or wastes containing a toxic or poisonous substance in sufficient quantity to injure or interfere with any sewage treatment process, to constitute a hazard to humans or animals, or to create any hazard in the receiving waters of the sewage treatment plant; 8. Any waters or wastes containing suspended solids of such character and quantity that unusual attention or expense is required to handle such materials at the sewage treatment plant; 9. Any noxious or malodorous gas or substance capable of creating a public nuisance; 10. Any liquid containing more than 350 parts per million by weight of suspended solids; or 11. Any discharge with an average daily flow greater than two percent of the average daily sewage flow of the city without the prior review and approval of the director. C. Protection of sanitary sewer system. The following provisions are enacted in an effort to protect the sanitary sewer system from obstruction and to ensure its proper operation. 1. FOG removal device required. All FOG generating facilities shall install, operate, and maintain FOG removal devices of an approved type and adequate size to effectively remove polar and nonpolar FOG, sludge, and settled solids from wastewater prior to the wastewater entering the public sanitary sewer. The city understands that there is a cost attributable to installing a FOG removal device. Therefore, all FOG generating facilities operating at a location within the city as of the original adoption date of this section (August 16, 2016) shall install a FOG removal device within 180 days of receiving notification by the city that such a FOG removal device is required, or such greater time period as determined appropriate by the director and warranted by the then-existing circumstances. All FOG generating facilities that open or relocate within the city after the above-referenced adoption date must install, operate, and maintain a FOG removal device in compliance with this chapter prior to commencing operation. a. Installation of a FOG removal device. All FOG removal devices shall be installed as required by this chapter and shall conform in all respects to the Uniform Plumbing Code or other applicable building codes adopted for application in the city through Chapters 13.01 and 14.01 KCC, including size, type, and installation method, unless otherwise approved by the director. Plans, specifications, and other pertinent information relating to proposed FOG removal devices shall be submitted for the approval of the director. No construction of such facilities shall be commenced until such approvals are obtained in writing. FOG generating facilities are responsible for obtaining a plumbing permit and final inspection approval before the FOG removal device may be put into operation. A FOG removal device shall be installed at locations where they are readily and easily accessible for cleaning, maintenance, and inspection. b. Maintenance of FOG removal device. All FOG removal devices shall be maintained and operated by the FOG generating facility at its own expense. These FOG removal devices shall be kept in continuous operation at all times, and shall be maintained in accordance with the Uniform Plumbing Code, established BMPs, and other federal, state, and local law. i. Minimum frequency of maintenance. At a minimum, all FOG removal devices shall be maintained as required by this subsection. However, an increase in the cleaning frequency and additional BMPs may be required to reflect the actual operating conditions of each FOG generating facility. (A) Grease interceptor. Maintenance of grease interceptors must be scheduled often enough so that polar FOG and settled solids and sludge do not leave the device through its outlet. At a minimum, the grease interceptor must be cleaned when: (i) the volume of FOG and settled sludge and solids constitute 25 percent of the effective liquid volume; or (ii) if the inlet or outlet displays visible buildup or is obstructed with FOG or other debris. In no event shall the maintenance frequency be less than once every six months. (B) Grease trap. Maintenance of grease traps must be scheduled often enough so that FOG and settled solids and sludge do not leave the device through its outlet. At a minimum, grease traps shall be cleaned when: (i) the volume of FOG and settled sludge and solids constitute 25 percent of the effective liquid volume; or (ii) if the inlet, outlet, flow control, or vent displays visible buildup or is obstructed with FOG or other debris. In no event shall the maintenance frequency be less than once every month. Unless specifically required or permitted by the city, no food waste disposal unit or dishwasher shall be connected to or discharge into any grease trap. (C) Oil/water separator. Oil/water separators shall be cleaned when the buildup is eight inches deep in the inlet chamber or when there are two inches or more of oil in any chamber of the oil/water separator. Coalescing plates must be cleaned before they become coated with silt or solids. ii. Performance of maintenance. Cleaning, inspection, and maintenance must be performed by a licensed contractor and/or wastehauler qualified to perform such activities on a FOG removal device. (A) Required maintenance for grease interceptors and oil/water separators. Maintenance for grease interceptors and oil/water separators shall include without limitation the removal of the full contents of the grease interceptor and oil/water separator including polar and nonpolar FOG, liquids, and settled sludge and solids from the device’s walls, baffles, inlet, outlet tee, piping, and floors. During maintenance, grease interceptors and oil/water separators shall be inspected for internal and external damage, obstructions, leaks, and missing or damaged components. It is a violation of this chapter to merely skim the surface layer of waste material, to only partially clean the grease interceptor or oil/water separator, or to use any method that does not remove the entire contents of the grease interceptor or oil/water separator. The grease interceptor and oil/water separator shall be filled with clean cold water before returning to service. If cleaning and repairs are required, they shall be performed within seven days of discovery. (B) Required maintenance for grease traps. Maintenance for grease traps shall include without limitation the removal of the full contents of the device including FOG, liquids, and settled sludge and solids. Removable baffles, plugs, and outlets shall be removed and cleaned, and the walls, cleanout, and all other components of the device shall be scraped free of accumulated FOG and food waste. During maintenance, the device shall be inspected for leaking seams and pipes; damaged or missing gaskets, lids, bolts, and latches; corrosion; and for effective operation of the baffles, venting, and flow-regulating device. The grease trap shall be filled with cold clean water before it is returned to service. If cleaning and repairs are required, they shall be performed within seven days of discovery. iii. Disposal of material removed during maintenance. All FOG removed from a FOG generating facility shall be disposed of or recycled in accordance with federal, state, and local laws. iv. Maintenance records. Records of all maintenance activities shall be retained after each maintenance event and shall be made readily available to the city for review via email or in person. 2. Industrial wastes – Control manhole – When required. Any business, establishment, or person who uses the sanitary sewer system to carry industrial wastes shall install and properly maintain a suitable control manhole in the premises’ sewer to facilitate observation, sampling, and measurement of the wastes. Such manhole shall be installed at a location where it is readily accessible, safe, and constructed in accordance with plans approved by the director. The control manhole shall be installed by the owner at the owner’s expense, and maintained by the owner so as to be safe and accessible at all times. 3. Waste cooking oil – Collection and proper disposal. Waste cooking oil shall be collected and stored in appropriate receptacles such as drums or bins at all FOG generating facilities and then disposed of or recycled in accordance with all federal, state, and local laws. Such storage receptacles shall be maintained by implementing proper BMPs to ensure they are watertight and do not leak. 4. Vegetable and fruit canneries – Collection and proper waste disposal. Vegetable and fruit canneries shall provide an efficient screen for the removal of skins, seeds, pomace, culls, discarded produce, and other suspended material and waste from the washing, sorting, or other canning processes. This screen must be 20-mesh, U.S. standard gauge, and may be of the vibrating, rotary, or any other effective type. It shall be located on the main outlet sewer line or lines from the cannery in such a way that all wastewaters, except cooling or other clean waters, will pass through the screen. Cooling or other clean waters may be bypassed around the screen or discharged through a separate outlet. Screened and other solid material removed from the product during cannery operations shall be disposed of in a manner consistent with state solid waste handling regulations, and, in any event, in such a manner that it will not enter a water of the state or the sanitary sewer system. 5. Standard applicable and measurement location. All measurements, tests, and analysis of the characteristics of waters and wastes to which reference is made in this chapter shall be determined in accordance with standard methods for the examination of water and sewage, available online at www.standardmethods.org, and shall be determined at the location of the control manhole required under subsection (C)(2) of this section and based upon suitable samples taken from that location. If no control manhole has been required under subsection (C)(2) of this section, the control manhole shall be considered to be the nearest downstream manhole in the sanitary sewer system at the point at which the building sewer is connected to the public sanitary sewer.
(Ord. No. 4210, § 2, 8-16-16)
Ask a question about Kent law
Corpus searches the Kent sections it holds and shows the ones that match, with their citations. Free, no sign-in.