§ 7.10.030 — Underground requirements
Kent City Code (current through Ordinance 4547, passed August 18, 2026) · Kent City Code § 7.10.030
Corpus is an independent public-information project, not the official City of Kent website. Stable reference: corpuslaw.us/code/190fe3b9-3938-4445-956c-8b197782fc6c
7.10.030 Underground requirements.
A. The following requirements shall apply to new facilities: 1. All major additions of new facilities of three (3) or more spans and/or five hundred (500) feet or more shall be underground. 2. Minor additions or new facilities may be constructed aerially where the growth requirements are uncertain or where existing facilities are aerial. A permit from the department of public works shall be required. B. The following requirements shall apply to rebuilds, replacements and additions: 1. A major rebuild or replacement of existing aerial facilities of three (3) or more spans and/or five hundred (500) feet or more shall be underground. 2. A minor rebuild or replacement of or addition to existing aerial facilities may be constructed aerially. No permit shall be required. 3. When there is casualty damage to an overhead service system due to the elements or other major service outage, the facilities may be restored aerially. No permit shall be required. 4. An addition of three (3) phase conductors or reconductoring will be allowed on existing aerial facilities. No permit shall be required. C. The following requirements shall apply to relocations or rearrangements: 1. Relocations or rearrangements of aerial facilities necessitated by, but not limited to, road widening, sewer and water main projects, shall be underground if replacement of poles and associated facilities are necessary to accommodate the improvement. 2. Relocations and rearrangements of aerial facilities not requiring major replacement of poles and associated facilities may be constructed aerially. D. Service connections are facilities extending from a distribution system and terminating on private property to serve a customer or subscriber. The following requirements shall apply to service connections: 1. Service connections shall be underground, if the distribution system serving the customer or subscriber is underground. 2. Service connections shall be underground if the distribution system serving the customer or subscriber is aerial, and the building, structure, or facility to be served is new, single-family residential construction. 3. Service connections may be aerial, if the distribution system serving the customer or subscriber is aerial, and the building, structure, or facility to be served is new construction under twenty thousand dollars ($20,000) in value. 4. Service connections may be aerial, if the distribution system serving the customer or subscriber is aerial, and the service request for building, structure or facility is the result of an addition, alterations, or repair thereto under twenty thousand dollars ($20,000) in value. 5. Service connections shall be underground, unless otherwise provided above. E. The following requirements shall apply to specific programs: 1. All areas zoned or unzoned for commercial or industrial use shall be converted to underground facilities within fifteen (15) years from the date of this chapter subject to a ten (10) year extension by the city, whereby in the city’s judgment, its financial situation prohibits the city from participating to the degree implied by this chapter. 2. Conversion to underground of existing aerial facilities shall be accomplished in an orderly manner and in conjunction with the city’s street widening and environmental improvement program. F. Street lighting facilities or systems conforming to current standards of the department of public works shall be installed as an integral part of all undergrounding projects constructed. G. All rights-of-way proposed to be dedicated to the city or easements for public facilities shall be subject to the provisions of this chapter. H. The owners of real property abutting an underground project shall be responsible at their expense for converting to underground service and disconnecting their aerial services within ninety (90) days following notice in writing of availability of such underground service. Time in consummating such connection and disconnection is of the essence and such notice to the property owner, customer or subscriber may be mailed or delivered in person. If the conversion and disconnection is not accomplished within ninety (90) days of receipt of notice, the city may order the work done and the actual cost shall constitute a lien against the real property subject to enforcement as provided by law. I. Plans for all aboveground installations shall be submitted to the planning department for approval of site screening and setbacks prior to the issuance of a service permit by the department of public works. J. Project drawing in form and scale conforming to generally accepted engineering practices, shall be submitted in duplicate to the department of public works within ninety (90) days of the completion of any underground project within the city.
(Ord. No. 1695, § 3; Ord. No. 2367, § 1. Formerly Code 1986, § 7.10.030)
Ask a question about Kent law
Corpus searches the Kent sections it holds and shows the ones that match, with their citations. Free, no sign-in.