§ 2.01.060 — Minimum building requirements and repair standards

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.01.060

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/0c04f5fb-3c26-42e2-9262-b4ebe048ba0e

§ 2.01.060: Minimum building requirements and repair standards.

No owner shall maintain, or permit to be maintained, any property which does not comply with the requirements of this chapter. All property shall be maintained to the Building Code requirements in effect at the time of construction. Alterations or repairs shall meet the minimum standards and repair standards set forth in this section. It is recognized that, in order to maintain the properties as required by this chapter, repairs will need to be made. Repairs, renovations, alterations, and additions in general will be required to meet the applicable codes in effect at the time they are undertaken, with the minimum acceptable standard of repair being made to bring the building or element of a building up to at least the minimum standards as listed in this section. The following provisions provide guidelines for these repairs, but when renovations, alterations, and additions are undertaken, they may require meeting a higher standard of repair than just meeting the minimum requirements set forth in this section. Requirements necessary for the strength, stability or proper operation of an existing fixture, structure or equipment, or for public health, safety or general welfare, not specifically covered by Chapter 2.01, shall be determined by the Building Official, as authorized in the Tacoma Municipal Code. Where there is a change of use or where there is a substantial renovation as defined by the Building Code, all work shall be in accordance with the Building Code, including the IEBC as adopted and amended in Chapter 2.02 of the Tacoma Municipal Code. A. Display of address number. Address numbers posted shall be the same as the number assigned by the City. All buildings shall have address numbers posted permanently in a conspicuous place on contrasting background so they may be read from the street or public way in accordance with the Fire Code. Tenant spaces in buildings shall be clearly numbered or lettered, in a logical and consistent manner. B. Foundations. Building foundation systems shall adequately support the building. Those parts of the system constructed of wood shall be free from deterioration or dry rot. Concrete and masonry elements shall be integral without substantial fracturing or cracks. Exterior walls shall be supported on a continuous concrete or masonry foundation, or an engineer-designed foundation system, which accounts for both vertical and lateral (earthquake and wind) loads, shall be provided. In absence of a continuous masonry or concrete foundation, an approved skirting system shall be provided to prevent the entrance of rodents and other animals to the crawl space or under-floor area of the building. When an existing foundation system supporting the exterior walls of a building is a post and beam system, and is found by inspection to be substandard, it shall either be replaced with a continuous concrete or masonry foundation system in accordance with the Building Code or shall be analyzed by an engineer as to its structural adequacy to support vertical and lateral loads and shall may be modified according to the engineering report to correct deficiencies, including earth/wood clearances. In crawl space construction using combustible materials, a minimum clearance in accordance with the Building Code shall be provided between the dirt and the floor joists or flooring, and between the dirt and floor beams. The dirt shall be covered by a 6-mil black polyethylene or approved equivalent moisture barrier. When the above under-floor clearances are required, access to the under-floor area shall be provided. Access to under-floor areas shall be provided with a minimum opening in accordance with the Building Code, unobstructed by pipes, ducts, and similar construction. All under-floor access openings shall be effectively screened or covered. Pipes, ducts, and other construction shall not interfere with the accessibility to or within under-floor areas. The building shall be anchored to the foundation system in accordance with the Building Code. EXCEPTIONS: 1. Skirting and other non-structural material, or occasional deteriorated or damaged structural members, may be replaced with the approval of the Building Official. 2. When proper under-floor clearance is not provided under an existing building, the Building Official may permit the required clearance to be provided only where plumbing or other equipment is located, provided there is at least adequate clearance to prevent deterioration of materials or where the wood is pressure-treated with approved wood preservatives. 3. Under-floor areas shall be ventilated by an approved mechanical means or by openings in the exterior foundation walls. 4. Mechanical ventilation. Mechanical ventilation shall meet the Building Code requirements. 5. Natural ventilation. If the under-floor space is to be provided ventilation by openings in the foundation walls, such openings shall in accordance with the Building Code. C. Floors. Floors shall be even, without breaks or holes, and constructed of materials of adequate strength to support the dead loads of the floor materials and the live loads required by the Building Code in effect at the time the building was built. Floors shall be reasonably level and free from deterioration and dry rot. Floors which are required to be repaired or reconstructed shall, as nearly as possible, follow the requirements of the Building Code for materials, floor loads, support, bracing, sheathing, and nailing. Where it is not practical, in the opinion of the Building Official, to repair or replace a floor to new Building Code standards, he or she may approve an alternate level of compliance, which is no less than that required by the Building Code in effect at the time the building was built. D. Exterior walls. Exterior walls and exposed exterior surfaces shall be structurally sound, and shall form a weather-tight barrier to the outside elements. Exterior walls shall be free from deterioration and dry rot. Exterior walls shall comply with the Building Code in effect at the time the building was built requiring fire resistance, parapets, and opening protection. Deteriorated or dry rotted elements of exterior walls shall be replaced or repaired. Siding and weather-resistant coatings or coverings shall be maintained in good condition. Exterior walls which are opened for repair shall be insulated as required by the Energy Code, as codified in Chapter 2.10 of the Tacoma Municipal Code or as hereafter amended. New or rebuilt exterior walls shall comply with the Building Code, including requirements for fire resistance, parapets, and opening protection. E. Windows and glazing. Windows and glazing shall be in good condition and maintain a weather barrier against the elements. All glazing shall be uncracked and unbroken. Operable windows shall be able to operate in the manner in which they were designed, and shall not be painted closed or otherwise bind in a manner rendering them inoperable. Sash weights and cords shall be intact and in good condition if needed for the operation of the windows. Frames and sashes shall be free of deteriorated or rotted materials. Broken glazing may be replaced with new glazing that matches the broken glass in thickness, thermal performance, fire resistance, and strength, provided that safety glazing shall be used to replace broken glass in all locations where safety glazing is required by the Building Code. All new windows, including glazing and frames, shall meet the Building Code for fire protection due to location relative to the property lines, safety glazing where glass is subject to impact as defined in the Building Code, and the thermal requirements of the Energy Code for building envelope and type of heating. EXCEPTION: In Group R, Division 3 Occupancies, as provided in Chapter 2.02 of the Tacoma Municipal Code, where new windows are provided with no modifications to the existing wall framing, the fire protection rating of the new windows shall be at least equal to the windows being replaced. F. Roofs. Roof structures shall be structurally sound and free of deteriorated or rotted materials. Roofing shall be weather-tight and provide protection to the interior of the building from outside elements. Roof drainage shall be directed to approved locations. Roofs shall be maintained in good repair. Roof systems shall be provided with adequate ventilation to prevent deterioration. An attic where the ceiling or roof is constructed of combustible materials and which has a vertical height of 30 inches or more shall be provided with an access opening as required by the Building Code in effect at the time the building was built. If one does not exist, an attic access opening to be provided which complies with the Building Code. Where ventilation is being added to roof systems, the aggregate net ventilation area shall be provided in accordance with the Building Code. Where attic access openings need to be provided, the opening shall be located in accordance with the Building Code. G. Exterior stairs, ramps, porches, and decks. Every exterior stair, ramp, porch, deck, or other exterior appurtenances, including guardrails and handrails, shall be constructed of materials of sufficient strength to perform the function for which it is designed and to carry the live and dead loads prescribed by the Building Code in effect at the time the building was built. All material shall be kept in sound condition and good repair. Replacement of materials shall be made as necessary of flooring treads, risers, stringers, decking, and other materials that show excessive wear and/or are broken, warped, loose, or deteriorated. Weather-exposed surfaces shall be protected in an approved manner. H. Exits. All buildings shall be provided with exits in accordance with the Building Code. Exits shall terminate at a public street or shall terminate to a place of refuge which is sufficiently large enough to receive all the occupants in the structure, and which is no less than 60 feet from the building or structure. EXCEPTION: Exiting systems which met the Building Code at the time that the building or structure was constructed, which have been maintained in good condition and do not pose a danger to life, in the opinion of the Building Official, may be accepted as an alternative to the Building Code. I. Doors, latches, and locks. The width and height for all exit doors shall comply with the Building Code in effect at the time the building was originally constructed, and shall be openable from the interior without a key or special knowledge. All doors serving an occupant load of 50 or more shall swing in the direction of egress. Doors serving an occupant load of less than ten, as calculated by the Building Code, may have dead bolts, provided a thumb operator, knob, or equivalent is installed on the interior side of the door. Dead bolts which require keys to be operated from the interior are not permitted. Doors serving occupancies classified per the Building Code as Group A (Assembly), Group E (Educational or Day Care), Group H (Hazardous), and Group I (Institutional) shall be provided with panic hardware when serving occupant loads of 50 or more as calculated by the Building Code, or when otherwise required by the Building Code. All new doors serving an occupant load of ten or more, as calculated by the Building Code, shall have a minimum width of not less than 36 inches and a minimum height of not less than 6 feet 8 inches, and shall be openable from the inside without a key or special knowledge. J. Corridors. Corridors shall be constructed in accordance with the provisions of the Building Code in effect at the time the building was constructed. New, reconstructed, or remodeled corridors shall be constructed in accordance with the provisions of the Building Code. The required fire resistive construction rating of walls, fire stops, shaft enclosures, partitions and floors shall be maintained in compliance with the Building Code in effect at the time of their construction. Alterations or minor modifications may require that the construction assembly be brought in compliance with the current Building Code. EXCEPTION: Existing duct penetration provided with fire dampers in accordance with the Building Code in effect at the time the building or structure was constructed do not need to be updated to the smoke/fire dampers required by the Building Code. K. Stairways and stair enclosures. Stairs shall be constructed as required by the Building Code in effect at the time the building was constructed. Stairs shall be enclosed when required by the Building Code in effect at the time the stair enclosure was constructed. New or rebuilt stairs shall be constructed as required by the Building Code. New stairs shall be enclosed, when required by the Building Code. EXCEPTIONS: 1. Stairways constructed prior to July 1, 1988, which serve occupant loads of ten or more, but which have risers in excess of 7 inches but not exceeding 7.5 inches, and/or have treads with a depth less than 11 inches but not less than 10 inches measured from tread nose to tread nose. 2. Buildings and structures which have fire escapes which have been maintained and tested in accordance with the Building Code and the Fire Code. See Subsection Q, Fire Escapes, of this chapter. L. Ramps. Ramps shall be constructed as required by the Building Code. Exception: Existing ramps which do not exceed a slope of one vertical to eight horizontal (12.5 percent) and which conformed to the Building Code in effect at the time the building or structure was constructed may be used for exiting purposes, provided there are landings at the top and the bottom of the ramp which have lengths equal to the width of the ramp, or 36 inches, whichever is greater. M. Guardrails. Unenclosed floor and roof openings, open and glazed sides of stairways, landings and ramps, balconies or porches, which are more than 30 inches above grade or floor below, and roofs used for other than service of the building shall be protected by a guardrail. Height. The top of guardrails shall meet the requirements of Building Code in effect at the time the guardrail was built, but need not exceed 42 inches in height. New guardrails, and guardrails which need to be replaced, shall meet all the requirements set forth for guardrails in the Building Code. Openings. Open guardrails shall have intermediate rails or an ornamental pattern that complies with the Building Code in effect at the time the guardrail was built. If the guardrail is new or needs to be reconstructed, the intermediate rails or ornamental pattern shall comply with the presently adopted Building Code. If the existing guardrail does not have intermediate rails or an ornamental pattern, intermediate rails or an ornamental pattern shall be provided which complies with the presently adopted Building Code. EXCEPTION: Guardrails need not be provided at the following locations: 1. | On the loading side of loading docks. 2. | On the auditorium side of a stage, raised platforms, and other raised floor areas, such as runways, ramps, and side stages used for entertainment or presentation; along the side of an elevated walking surface, when used for the normal functioning of special lighting or for access and use of other special equipment; at vertical openings in the performance area of stages. 3. | Along vehicle service pits not accessible to the public. EXCEPTION: 1. | The top of guardrails for Group R, Division 3 and Group U, Division 1 Occupancies, and interior guardrails within individual dwelling units, Group R, Division 3 congregate living facilities and guest rooms of Group R, Division I Occupancies, do not need to exceed 36 inches in height, or as otherwise required by the Building Code. 2. | The top of guardrails on a balcony immediately in front of the first row of fixed seats and which are not at the end of an aisle may be 26 inches in height. 3. | The top of guardrails for stairways, exclusive of their landings, may have a height as specified in the Stairway Handrails section of this chapter. N. Stairway handrails. Stairways shall have handrails on each side, and every stairway required to be more than 88 inches in width shall be provided with not less than one intermediate handrail for each 88 inches of required width. Intermediate handrails shall be spaced approximately equally across with the entire width of the stairway. The top of handrails and handrail extensions shall meet the requirements of the Building Code in effect at the time the stairway was built, but in no case shall be less than 30 inches nor more than 38 inches above the nosing of treads and landings. Handrails shall be continuous the full length of the stairs. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. The handgrip portion of handrails shall meet the requirements of the Building Code in effect at the time the stairway was built. The handgrip portion of handrails shall have a smooth surface with no sharp corners. Handrails projecting from a wall shall have a space of not less than 1-1/2 inches between the wall and the handrail. Handrails used to protect the open side of stairways or landings shall be provided with intermediate rails or an ornamental pattern, when the drop from the stairs or landing is 30 inches or more to the ground or surface below. The intermediate rails or patterns shall be as required by the Building Code under which it was constructed. If such handrail is new or being replaced, it shall meet the requirements of the presently adopted Building Code. If such handrail is existing, but is not provided with intermediate rails or ornamental pattern, intermediate rails or an ornamental pattern shall be provided to comply with the presently adopted Building Code. Where stairways are missing handrails, handrails shall be provided which meet all the requirements of the presently adopted Building Code. EXCEPTIONS: 1. Stairways less than 44 inches in width or stairways serving one individual dwelling unit in Group R, Division 1 or Division 3 Occupancies, or a Group R, Division 3 congregate living facilities, may have one handrail, or as otherwise permitted by the Building Code. 2. Private stairways 30 inches or less in height may have handrails on one side only. 3. Stairways having less than four risers and serving one individual dwelling unit in Group R, Division 1 or Division 3, or a Group R, Division 3 congregate living facilities, or serving Group U Occupancies, need not have handrails. O. Exit path lighting. General. Except within individual dwelling units, guest rooms, and sleeping rooms, exits shall be illuminated at any time the building is occupied, with light having intensity in accordance with the Building Code. Sources of Power. The power supply for exit illumination shall normally be provided by the premises’ wiring system. Emergency backup power or power on separate circuits shall be in accordance with the Building Code in effect at the time the lighting was installed. Exit path shall be illuminated at all times the building or structure is occupied. Exit path lighting shall provide a minimum illumination at floor level in accordance with the Building Code. Where exit path lighting in existing buildings is missing or is required to be upgraded, it shall meet the following requirements: Separate Sources of Power. The power supply for exit illumination shall normally be provided by the premises’ wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system for Group I, Divisions 1.1 and 1.2 Occupancies, and for all other occupancies where the exiting system serves an occupant load of 100 or more. Emergency systems shall be supplied from storage batteries or an on-site generator set and the system shall be installed in accordance with the requirements of the Electrical Code, as codified in Chapter 12.06A of the Tacoma Municipal Code. EXCEPTION: In auditoriums, theaters, concert or opera halls, and similar assembly uses, the illumination at floor level may be reduced during performances to lower levels allowed in the Building Code. P. Exit signs. Where Required. When two or more exits from a story are required, exit signs shall be installed at stair enclosure doors, horizontal exits, and other required exits from the story. When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction and path of egress. Graphics. The color and design of lettering, arrows, and other symbols on exit signs shall be in accordance with the currently adopted Building Code, or in accordance with the Building Code in effect at the time the original signs were installed. Illumination. Signs shall be internally or externally illuminated in accordance with the Building Code in effect at the time the exit signs were installed. Signs shall be internally or externally illuminated by two electric lamps or shall be or an approved self-luminous type. When the luminance on the face of an exit sign is from an external source, it shall have an intensity of not less than 5.0 foot-candles from either lamp. Internally-illuminated signs shall provide equivalent luminance. Power Supply. Current supply to one of the lamps for exit signs shall be provided by the premises’ wiring system. Power to the other lamp shall be from storage batteries or an on-site generator set, and the system shall be installed in accordance with the Electrical Code or in accordance with the Building Code in effect at the time the exit signs were installed. Refer to Building Code for requirements for exit signs in high-rise buildings and for amusement structures. EXCEPTIONS: 1. Main exterior exit doors, which obviously and clearly are identifiable as exits, need not be signed when approved by the Building Official. 2. Group R, Division 3, and individual units of Group R, Division 1 Occupancies. 3. Exits from rooms or areas with an occupant load of less than 50 where allowed within Group I or Group E daycare occupancies. Q. Fire escapes. New fire escapes shall not be permitted to be installed. Existing fire escapes complying with this section may be accepted by the Building Official as one of the required exits. The fire escape shall not be the primary or the only exit. Fire escapes shall not take the place of stairways required by the codes under which the building was constructed. Fire escapes shall be subject to reinspection as required by the Building Official. The Building Official shall require documentation to show compliance with the requirements of this section. Fire escapes shall comply with the following: 1. All openings in an exterior wall below or within 10 feet, measured horizontally, of an existing fire escape serving a building over two stories in height, shall be protected by a self-closing fire assembly having a three-fourths-hour fire protection rating. When located within a recess or vestibule, adjacent enclosure walls shall be of not less than one-hour fire-resistive construction. 2. Egress from the building shall be by an opening having a minimum clear width and height of not less than 29 inches. Such openings shall be openable from the interior without the use of a key or special knowledge or effort. The sill of an opening giving access to the fire escape shall not exceed 30 inches above the floor of the building or balcony. The top of the frame of the opening giving access to the fire escape shall be a minimum of 59 inches above the floor. 3. Fire escape stairways and their balconies shall support their dead load plus a live load of not less than 100 pounds per square foot or a concentrated load of 300 pounds placed anywhere on the balcony or stairway so as to produce the maximum stress conditions. The stairway shall have a slope not to exceed 60 degrees from the horizontal and shall have a minimum width of 18 inches. The stairway shall be provided with a top and intermediate railing on each side. Treads shall not be less than 4 inches in width, and the rise between treads shall not exceed 10 inches. All stairway and balcony railings shall support a horizontally applied force of not less than 50 pounds per lineal foot of railing or a concentrated load of 200 pounds placed anywhere on the railing so as to produce the maximum stress conditions. 4. Fire escape balconies shall not be less than 44 inches in width with no floor openings greater than 5/8 inch in width except the stairway opening. Stairway openings in such balconies shall not be less than 22 inches by 44 inches. The guardrail of each balcony shall not be less than 36 inches high with not more than nine inches between intermediate rails. 5. Fire escapes shall extend to the roof or provide an approved gooseneck ladder between the top floor landing and roof when serving buildings four or more stories in height having roofs with a slope not exceeding 4 in 12. Such ladders shall be designed and connected to the building to withstand a horizontal force of 100 pounds per lineal foot; each rung shall support a concentrated load of 500 pounds placed anywhere on the rung so as to produce the maximum stress conditions. All ladders shall be at least 15 inches in clear width, be located within 12 inches of the building, and shall be placed flat wise relative to the face of the building. Ladder rungs shall be 3/4 inch in diameter and shall be located 10 inches to 12 inches on center. Openings for roof access ladders through cornices and similar projections shall have minimum dimensions of 30 inches by 33 inches. 6. The lowest balcony shall not be more than 18 feet from the ground. Fire escapes shall extend to the ground or be provided with counter-balanced stairs reaching the ground. 7. Fire escapes shall be kept clear and unobstructed at all times and shall be maintained in good working order. Fire escape stairways, balconies, railings, and ladders shall be visually inspected annually and shall be subjected to a stress test every five years in accordance with the provisions of Chapter 3.02 of the Tacoma Municipal Code. Fire escapes failing the stress test shall be repaired or removed from the building, as directed by the Fire Chief. If the fire escape is removed from the building, it shall be replaced with stairways meeting all requirements for stairways in new construction. 8. The fire escapes shall be periodically tested and inspected in accordance with the Fire Prevention Code. 9. The fire escape shall have clearance from electrical service conductors as required by the Electrical Code. R. Exits for sleeping rooms. All sleeping rooms below the fourth story in buildings shall be provided with two exits. One of the exits may be a window opening onto a public way or into a court or yard which provides access to a public way. Such exit window shall provide a net openable area of 5.7 square feet with a minimum clear width of 20 inches and a minimum clear height of 24 inches, and a maximum sill height of 44 inches measured from the floor of the sleeping room. Escape and rescue windows with a finished sill height below the adjacent ground elevation shall have a window well. Window wells at escape or rescue windows shall comply with the following: 1. | The clear horizontal dimensions shall allow the window to be fully opened and provide a minimum accessible net clear opening of nine square feet, with a minimum dimension of 36 inches. 2. | Window wells with a vertical depth of more than 44 inches shall be equipped with an approved permanently affixed ladder or stairs that are accessible with the window in the fully open position. The ladder or stairs shall not encroach into the required dimensions of the window well by more than 6 inches. Bars, grilles, grates, or similar devices may be installed on emergency escape or rescue windows, doors, or window wells, provided: 1. | The devices are equipped with approved release mechanisms which are openable from the interior without the use of a key or special knowledge or effort; and 2. | The building is equipped with smoke detectors installed in accordance with the Building Code. EXCEPTIONS: 1. | In buildings constructed prior to May 26, 1981, existing window with a net openable area of five square feet, a minimum clear width of 22 inches, a minimum clear height of 22 inches, and a maximum sill height of 48 inches measured from the floor of the sleeping room, shall be deemed to meet the exit window requirement. Where the window frame is to be replaced, this exception shall not apply, except as necessary to fit within the rough framed opening, in which case the opening dimensions shall be maximized. (Note: If a new opening needs to be created or an existing opening needs to be enlarged to provide an exit window from a sleeping room, this exception shall not apply.) 2. | Where the sill height exceeds the maximum specified, including when Exception 1 applies, a landing with a minimum depth of 24 inches and width equal to the width of the window and frame, but not less than 36 inches, may be provided directly below the exit window within the sleeping room, provided: stairs shall be provided to the landing if its height exceeds 12 inches above the sleeping room floor, and that the landing and stairs do not decrease the minimum required dimensions of the sleeping room below those required by this chapter and the Building Code. 3. | The size of egress windows below the fourth floor opening onto a court yard may be modified by the Building Official or the Fire Chief. S. Minimum room dimensions for residential buildings. 1. Ceiling heights. Habitable space shall have a ceiling height of not less than seven feet. Where exposed beam ceiling members are spaced at less than 48 inches on center, ceiling height shall be measured to the bottom of these members. Where exposed beam ceiling members are spaced at 48 inches or more on center, ceiling height shall be measured to the bottom of the deck supported by these members, provided that the bottoms of the members are not less than seven feet above the floor. If any room in a building has a sloping ceiling, the prescribed ceiling height for the room is required in only one-half the area thereof. No portion of the room measuring less than five feet from the finished floor to the finished ceiling shall be included in any computation of the minimum area thereof. If any room has a furred ceiling, the prescribed ceiling height is required in two-thirds the area thereof, but in no case shall the height of the furred ceiling be less than seven feet. The Building Official may permit lower ceiling heights where existing conditions make the strict compliance with this section impractical. 2. Floor area. Dwelling units and congregate residences shall have at least one room which shall have not less than 120 square feet of floor area. Other habitable rooms, except kitchens, shall have an area of not less than 70 square feet. Sleeping rooms shall be increased in floor area by a minimum of 50 square-feet for each occupant in excess of two. Efficiency dwelling units shall comply with the requirements of Subsection T. 3. Width. Habitable rooms, other than a kitchen, shall not be less than seven feet in any dimension. T. Efficiency dwelling units. An efficiency dwelling unit shall conform to the requirements of the Building Code in effect at the time the building was constructed, except as herein provided: 1. The unit shall have a living room of not less than 220 square feet of superficial floor area. An additional 100 square feet of superficial floor area shall be provided for each occupant of such unit in excess of two. 2. The unit shall be provided with a separate closet. 3. The unit shall be provided with a kitchen sink, cooking appliance, and refrigeration facilities, each having a clear working space of not less than 30 inches in front. Light and ventilation conforming to this chapter shall be provided. 4. The unit shall be provided with a separate bathroom containing a water closet, lavatory, and bathtub or shower. U. Residential dwelling or dwelling unit room arrangement. Rooms in dwellings or dwelling units shall be so arranged that access to all sleeping rooms can be made directly without traveling through other sleeping rooms, bathrooms, or water closet compartments. Dwellings and dwelling units shall be self-contained, with access to all portions being possible without leaving the dwelling or dwelling unit. Rooms in dwellings and dwelling units containing two or more sleeping rooms shall be arranged in such a manner that bathroom or water closet compartment access is provided without traveling through a sleeping room. EXCEPTION: Where each bedroom has its own bathroom facilities. V. Overcrowding, residential buildings. For single-family dwellings, duplexes, and multi-family dwellings with three or more units, the maximum number of residents of each dwelling unit shall not exceed the gross area divided by 200, rounded to the nearest whole number. Bedrooms will accommodate two persons with a minimum size of 70 square feet, with no dimension being less than seven feet. An additional 50 square feet shall be provided for each person in excess of two. Children less than one year of age shall not be considered in applying the above provisions. W. Smoke alarms, carbon monoxide alarms, fire sprinkler systems, and fire alarm systems. 1. Smoke alarms. a. General. Group I-1 and Group R occupancies, as defined in the Building Code, shall be provided with single-and multiple-station smoke alarms in accordance with the Fire Code. Note: This requirement applies to all existing I-1 and Group R occupancies including those not undergoing additions, alterations, or repairs. b. Power source. Smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source, and shall be equipped with a battery backup. The detector shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than those required for over-current protection. Smoke alarms may be solely battery operated when installed in existing buildings where no construction is taking place; in buildings that are not served from a commercial power source; and in existing areas of buildings undergoing alterations or repairs that do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic crawl space or basement available which could provide access for interconnection without the removal of interior finishes. c. Location within dwelling and sleeping units. A smoke alarm shall be installed within each sleeping room and directly outside of each sleeping area in the immediate vicinity of bed rooms. A minimum of one smoke alarm shall be installed on each story, including those without sleeping rooms. Dwelling units equipped with smoke alarms compliant with the Building Code in effect at the time of construction or smoke detectors connected to a fire alarm system as a substitute for smoke alarms shall be deemed sufficient. d. Additional locations in hotels. In addition to those smoke alarms required by Subsection C above, single- or multiple-station smoke alarms shall be located in every room in the path of egress from the sleeping area to the door leading from the sleeping unit. 2. Carbon Monoxide Alarms shall be installed in existing apartments, condominiums, hotels, motels, and single-family residences in accordance with the Fire Code. 3. Fire alarm systems. a. | Group R-2 occupancies three or more stories in height or containing 16 or more dwelling units shall be equipped with a fire alarm system. b. | Group R1 occupancies containing 20 or more guest rooms, or as part of a high-rise building shall be equipped with a fire alarm. EXCEPTIONS: a. | A manual fire alarm system need not be provided in buildings not over two stories in height when all individual dwelling units and contiguous attic and crawl spaces are separated from each other and public or common areas by at least one-hour fire-resistive occupancy separations and each individual dwelling unit or guest room has an exit directly to a public way, exit court, or yard. b. | A separate fire alarm system need not be provided in buildings which are protected throughout by an approved, supervised fire sprinkler system having a local alarm to notify all occupants. The alarm signal shall be a distinctive sound which is not used for any other purpose other than the fire alarm. The minimum sound pressure levels shall be 75 decibels and shall not exceed a maximum of 110 decibels. c. | Occupancies Other Than Group R. Fire alarm systems shall be provided in all other buildings other than Group R occupancies in accordance with any currently adopted requirement to do so or the provisions of the Building Code and Fire Code in effect at the time the building was constructed, or when last substantially renovated, remodeled, extended, or altered. 4. Fire Alarm Systems and Fire Sprinkler systems and equipment used to detect a fire, activate an alarm, or suppress or control a fire, or any combination thereof shall be maintained in an operable conditions at all times in accordance with the Fire Code. All inspections, testing, and maintenance of fire sprinkler systems shall be in accordance with the Fire Code. X. Kitchen facilities. Each dwelling unit shall be provided with a kitchen. The kitchen area shall contain a sink with hot and cold running water and suitable space and equipment to store, prepare, and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage such as stoves, ovens, refrigerators, microwaves, freezers, cabinets, countertops, and drawers in sufficient quantity and in a condition that the occupants can store their food safely and at appropriate temperatures to protect the food. Kitchens shall be provided with light, electrical outlets, and ventilation meeting the minimum standards set forth in this chapter. Kitchens shall have a minimum clear passageway of three feet between counter-fronts and appliances or counter-fronts and walls. Communal kitchens shall be permitted only in rooming house or boarding homes. Such communal kitchens shall be located within a room accessible to the occupants of each guest room sharing the use of the kitchen without going outside the rooming house or boarding home, or going through a unit of another occupant. Commercial kitchens shall comply with the Mechanical Code in effect at the time the kitchen was constructed, and the requirements of the Tacoma-Pierce County Health Department. Commercial kitchens shall be provided with grease hoods and grease traps or interceptors when determined necessary by applicable code. Y. Laundry facilities. Where laundry facilities are provided, they shall meet minimum requirements such as lighting, ventilation, and water heating in accordance with the provisions of the codes in force at the time the building was constructed. In an apartment house, where laundry facilities are not provided for each unit, laundry trays or washing machines shall be provided elsewhere on site and shall be available to tenants. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted outside the structure in accordance with the manufacturer’s instructions unless the listing on the appliance is for a ductless system. Z. Electrical system and lighting. All occupied buildings shall be connected to an approved source of electrical power. An approved source of electrical power shall be Electrical Utilities authorized to furnish electrical power within the limits of the City of Tacoma. All electrical equipment, components, and wiring shall be installed and maintained in a safe manner in accordance with applicable codes. All electrical equipment shall be listed by an approved testing and/or listing agency. All damaged or missing electrical components or equipment shall be replaced, repaired, or removed as appropriate. Flexible cords or extension cords shall not be used for permanent wiring, or for running through doors, windows, or cabinets or concealed within walls, floors, or ceilings. The electrical system shall be safe and not be a shock or fire hazard to the occupants of the building. Services shall be adequately sized and provided with fuses, breakers, and other appropriate safety equipment. Wiring shall be maintained in a safe condition. Exit facilities and other hallways and stairs shall be provided with supplied and operable lighting capable of providing a minimum of one foot-candle lighting intensity at floor level. Emergency power shall be provided if required by the code under which the building was constructed. Every habitable room shall contain at least two supplied and operable electrical convenience outlets, or one supplied electric convenience outlet and one supplied and operable light fixture. Every kitchen, furnace room, and laundry room shall contain at least one supplied electric convenience outlet and one supplied and operable light fixture. Every bathroom, rest room, and toilet compartment shall contain at least one supplied and operable electric light fixture. In addition, every room containing lavatories shall be provided with at least one convenience outlet. AA. Heating, mechanical, and elevator equipment. Heating equipment shall be provided to heat every dwelling and guest room, and shall have the capacity to heat all habitable rooms to 70 degrees Fahrenheit with an ambient outside temperature of 20 degrees Fahrenheit. Such equipment shall be in compliance with the Mechanical Code or the Building Code in effect at the time of installation. Solid-fuel-burning appliances or cooking appliances and portable heating devices shall not be used to provide the primary heat for the dwelling or guest rooms. A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel burning equipment. Elevators shall be maintained in compliance with the Building Code. BB. Water heating equipment. Every dwelling or dwelling unit shall have water heating equipment which is properly installed and maintained in safe and good working condition. Such equipment shall be provided with piping to distribute the hot water to all locations required by the Building, Plumbing, and Mechanical Codes and this chapter. Water heating equipment shall be capable of heating water to 120 degrees Fahrenheit in quantities to permit a reasonable amount of hot water to be drawn at every required kitchen sink, lavatory, bathtub, or shower on demand. Hot water heating equipment shall have its thermostat set no lower than 120 degrees Fahrenheit, and shall be provided with all safety equipment prescribed by the Plumbing and Mechanical Codes. Water-heating equipment required by this section shall be independent of the building heating system. CC. Light and ventilation. 1. Lighting. All occupied portions of buildings shall be provided with natural or artificial light. All habitable rooms in residential dwelling buildings or dwelling units shall be provided with natural light. Natural light shall be provided for each room by windows and/or skylights which combine to have a minimum area of one-tenth (1/10) of the floor area of the room or combination of rooms being considered. Artificial light shall be provided with electrical fixtures wired to house power provided by a supply utility which provide a minimum light intensity of 1.0 foot-candle at floor level. Existing lighting which met the Building Code in effect at the time the building was constructed, has been maintained in safe condition, and which provides the minimum 1.0 foot-candle at floor level is deemed as meeting this section. New lighting shall be required to meet the Washington State Energy Code. Adjacent rooms may be considered as one room, provided that the opening in the wall between the two rooms provide a minimum clear opening of one-tenth (1/10) of the floor area of the interior room, 25 square feet, or one-half of the area of the wall between the rooms, whichever is greater. 2. Ventilation. All occupied portions of buildings shall be provided with natural or mechanical ventilation. Natural ventilation shall be by means of openable windows, doors, skylights, or other approved openings to the exterior of the building. Natural ventilation shall be provided accordance with the Building and Mechanical Code. Existing mechanical ventilation meeting the requirements of the Building and Mechanical Codes in effect at the time the building was constructed shall be considered satisfactory. New or revised mechanical ventilation shall meet the requirements of the Building and Mechanical Code. DD. Solid-fuel-burning appliances. Solid-fuel-burning appliances shall be listed by an approved testing agency and shall be installed in accordance with their listing and with the manufacturer’s installation instructions, and shall comply with the applicable Washington State Department of Ecology emissions standards and/or the United States Environmental Protection Agency emission standards for air quality. The appliance shall be vented in accordance with Building and Mechanical Code and manufacturer’s listing. Masonry chimneys must be lined. Factory-built chimneys shall be listed by an approved testing agency and shall be installed in accordance with their listing. The installation of a used appliance is prohibited, except for engineered installations with prior approval by the Building Official or other authorities having jurisdiction. EXCEPTION: Solid-fuel-burning furnaces with an approved ducted heat distribution system and an automatic fuel delivery system. A building permit is required for the installation of a solid-fuel-burning device. EE. Chimneys. Every smoke pipe and every chimney shall remain adequately supported and free from obstructions and shall be maintained in a condition which ensures there will be no leakage or back-up of noxious gases. Every chimney shall be reasonably plumb. Loose bricks or blocks shall be rebonded. Loose or missing mortar shall be replaced. Unused openings into the interior of the structure must be permanently sealed using approved materials. Chimneys used for approved gas appliances shall be lined with approved materials. Masonry chimneys supported on chimney brackets (“shelf chimneys”) shall be removed, or the chimney shall be modified to provide an approved support system. FF. Plumbing. Supply, waste, and vent plumbing piping shall be in good condition and free from leaks. Waste piping shall be adequately sized to safely convey waste water to the City sewer or to other approved plumbing waste disposal systems. Vent piping shall be adequately sized and configured to prevent siphoning of plumbing fixture traps. All plumbing fixtures shall be in good condition, free from cracks and leaks, and shall be properly connected to the waste and vent system of the building. GG. Number of plumbing fixtures. Dwelling Units: Every dwelling unit shall be provided with a kitchen sink, a water closet, a lavatory (bathroom sink), and either a bathtub or a shower. Lodging Houses: Lodging Houses shall be provided with a minimum of a kitchen sink, a water closet, a lavatory (bathroom sink), and a bathtub or a shower, provided that where the bathtub or shower is provided in the same room as a water closet and lavatory, there shall be an additional water closet and lavatory in the building in a different location. Apartment Houses, Hotels, and Motels: Each apartment house dwelling unit, hotel unit, or motel unit shall be provided with a water closet, a lavatory (bathroom sink), and a bathtub or a shower. EXCEPTIONS: Apartment houses, hotels, and motels existing prior to January 1, 1961, which contain communal toilet and bathing facilities, rather than facilities for each unit, may continue operation without requiring modification, provided: 1. | There are separate toilet and bathing facilities for each sex. 2. | Toilet and bathing facilities shall be separate from each other or of adequate size to permit simultaneous use. 3. | The men’s toilet facilities shall contain: Water Closets: One for every ten guest rooms, or fraction thereof, but not less than one. Urinals: One for every 25 guest rooms, or fraction thereof, but not less than one. Lavatories: One for every 12 guest rooms, or fraction thereof, but not less than one. 4. | The women’s toilet facilities shall contain: Water Closets: One for every eight guest rooms, or fraction thereof, but not less than one. Lavatories: One for every 12 guest rooms or fraction thereof, but not less than one. 5. | The bathing facilities for each sex shall contain: One shower and bathtub combination and, in addition, shall provide one additional shower for every eight guest rooms over eight. Dormitories: Dormitories shall provide toilet facilities in accordance with the exception listed for Hotels and Motels. Commercial and Industrial Buildings: Commercial and Industrial Buildings shall be provided with toilet facilities for each sex. Each toilet facility shall be provided with a minimum of one water closet and one lavatory. In addition, each men’s toilet facility shall also be provided with a urinal where there are more than four persons using the facility. EXCEPTIONS: 1. | Commercial and Industrial buildings may provide a single toilet facility with a lockable door where the total occupant load is 15 or less. 2. | Restaurants with a total occupant load including customers and employees of 15 or less may provide a single toilet facility with a lockable door. 3. | Toilet facilities which provided adequate fixtures in accordance with the Building Code in effect when the building was constructed. HH. Sanitation. 1. | Floors. In other than dwelling units, toilet room floors shall have a smooth, hard, nonabsorbent surface, such as Portland cement, concrete, ceramic tile, or other approved material, which extends upward onto the walls at least five inches. 2. | Walls. Walls within two feet of the front and sides of urinals and water closets shall have a smooth, hard, nonabsorbent surface of Portland cement, concrete, ceramic tile, or other smooth, hard, nonabsorbent surface to a height of four feet, and except for structural elements, the materials used in such walls shall be of a type which is not adversely affected by moisture. EXCEPTIONS: 1. | Dwelling units and guest rooms. 2. | Toilet rooms which are not accessible to the public and which have not more than one water closet. 3. | Hardware. In all occupancies, accessories such as grab bars, towel bars, paper dispensers, and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture. 4. | Bathtub and shower. Bathtub and shower enclosures in all occupancies shall be finished as specified in items 1 and 2 above, to a height of not less than 70 inches above the drain inlet. Materials other than structural elements used in such walls shall be of a type which is not adversely affected by moisture. 5. | Water closet room separation. A room in which a water closet is located shall be separated from food preparation or food storage rooms by tight-fitting doors. II. Infestation. Every building shall be kept free from infestations of vermin. Where infestations of vermin are found, they shall be promptly eliminated by extermination. After elimination of infestations, proper precautions shall be taken to prevent reinfestations. JJ. Accessory structures. All accessory structures shall be maintained structurally safe and sound and in good repair. All exterior surfaces of accessory structures shall be of a material specifically for use in such a weather-exposed location. Accessory structures shall not be used for the storage of garbage or rubbish unless such garbage or rubbish is placed in an approved container or stored in a manner so as not to constitute a health or safety hazard. An accessory structure shall contain no habitable space. No person shall occupy or allow another to occupy an accessory structure for living purposes. Plumbing shall not be permitted in an accessory structure, except as permitted by the Tacoma Land Use Regulatory Code, codified in Title 13 of the Tacoma Municipal Code. Accessory buildings are not permitted on building lots separate from the main building, except as permitted by the Tacoma Land Use Regulatory Code. Detached accessory buildings located on a site where the main building has been removed may remain on the lot for up to a year, without the main building being replaced. EXCEPTION: With the permission of the Building Official, accessory buildings may remain on a building lot where the main building has been destroyed for longer than one year, for sufficient reasons, presented to the Building Official in writing. KK. Accessibility for the physically disabled. All buildings shall be in compliance with the provisions of the Building Code. LL. Exterior maintenance. 1. Buildings. The exterior of buildings shall be maintained in a manner which appears neat and orderly. Weatherproofing elements, such as roofing and siding, shall be firmly attached and in good condition. Glazing and exterior doors shall be intact and in good repair. Painted surfaces shall be fully covered and all peeling or blisters shall be scraped and repainted. 2. Sidewalks, retaining walls and paving. The owner shall be responsible for maintaining sidewalks and other paving on the property. Sidewalks, retaining walls, and other paving on the property shall provide a reasonably even surface without potential hazards. 3. Exterior property areas, yards, and courts. The owner shall be responsible for maintaining all exterior property areas, yards, and courts in a reasonably neat, clean, and sanitary condition. Property areas shall be maintained free from any accumulation of garbage, litter, debris, overgrown, or noxious vegetation, or other conditions which constitute a nuisance as defined by Chapter 8.30 of the Tacoma Municipal Code. For the purposes of this section, owners shall be responsible for maintaining the property to the centerline of abutting public streets and alleys, pursuant to Chapter 9.17 of the Tacoma Municipal Code. MM. Interior maintenance. Interior wall, ceiling and floor coverings, interior doors, trim, cabinetry and their hardware shall be maintained in reasonable condition and if damaged repaired or replaced. Holes in drywall or other approved surfaces must be repaired to prevent the spread of fire and finished in an approved manner. Mold and mildew must be cleaned to prevent health issues and wall and ceiling coverings shall be painted if needed to ensure that the area is sanitary. NN. Cargo containers and semi-trailers. 1. Except as permitted by the Land Use Regulatory Code, cargo containers shall not be permitted to be used as storage buildings. 2. Semi-trailers shall not be used for storage buildings.

( Ord. 28255 Ex. A, 2014-11-04 ; Ord. 28348 Ex. A, 2016-03-08 ; Ord. 28443 Ex. B, 2017-08-01 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.