For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.16.140 — Service buildings – Trailer courts

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.16.140

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/0192a78f-6353-4b01-b3ea-dedc007e69e8

§ 2.16.140: Service buildings – Trailer courts.

An automobile house trailer court shall be provided with one or more service buildings adequately equipped with flush type toilets, lavatories, and shower baths. Service buildings shall be located within the trailer court so that no one house trailer lot is more than 300 feet from a service building. The floors and splash zones of such service buildings shall be of concrete or similar impervious material, the floors being elevated not less than four inches above grade and each room provided with floor drains properly connected to the sewer system as hereinbefore provided. Service buildings shall be provided with a heating facility capable of maintaining a temperature within the building of 70 degrees Fahrenheit at a point three feet above the floor under ordinary minimum winter conditions. Cold water shall be provided at a minimum rate of 50 gallons per day per house trailer lot. Water heating facilities shall be properly installed, maintained in safe and good working condition and properly connected to hot water lines as specified in the Plumbing Code and shall be capable further of heating water to such a temperature as to permit its being drawn at every required lavatory, shower bath, and service sink fixture at a temperature of not less than 120 degrees Fahrenheit. Such water heating equipment must be able to meet the above requirements independent of any space heating equipment. Service buildings shall be well ventilated and all exterior openings from toilet rooms shall be covered with 16 pound mesh screen during fly seasons. Toilet rooms shall be provided with self-closing doors. Toilet rooms shall be well lighted at all times and provided with window areas equivalent to at least 12 percent of the floor area. A. Service buildings shall be provided with bathroom facilities as follows: Lots | Toilets | Showers | Lavatories 1-25 | 1 | 1 | 1 26-70 | 2 | 2 | 2 One additional toilet shall be provided for each sex for each 100 additional lots or fractional part thereof in excess of 70 lots. Toilets shall be enclosed in separate compartments with a minimum of 12 square feet and with a minimum width of three feet; B. Each toilet room provided for men shall have in addition one water-flushed urinal stall per each 100 trailer lots or fractions thereof; C. Shower baths shall be provided for each sex within a minimum three-foot by three-foot area. Showers for women shall be provided with an enclosed dressing compartment with a stool or bench in a minimum three-foot by three-foot area as a contiguous part of the shower stall improvement.

( Ord. 16297 , 1959-03-02 ; Ord. 16993 § 2, 1962-02-20 ; Ord. 19397 § 4, 1971-08-03 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.