§ 11.22.R301.2(1): Amendment to Table R301.2(1).
Table R301.2(1) of the International Residential Code as adopted and maintained by the State Building Code Council is amended to read as follows: TABLE R301.2(1)CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load (a) | Wind Speed (mph) | Wind Topographic Effects | Seismic Design Category | Subject to damage from | Winter Design Temp | Ice Shield Underlayment Required | Flood Hazards | Air Freezing Index | Mean Annual Temp Weathering | Frost line depth | Termite 19 (b) | 85 | NO | C | SEVERE | 24 | S—M | 8 | Yes | 1973 | 1000 | 45 For SI: 1 pound per square foot = 0.0479 kN/m2, 1 mile per hour = 1.609 km/h. a. | Minimum uniform roof snow load shall be 20 psf up to elevations of 1,166 feet. Elevations above 1,166 feet shall be minimum 25 psf. b. | Case specific analysis may be utilized in lieu of prescriptive loads for elevations above 1,166 feet.
( Ord. 2005-09 § 1 (part), 2005 ; Ord. 2012-27 § 1 (Exh. A) (part), 2012 ; Ord. 2013-030 § 1 (Exh. A) (part), 2013 ; Ord. 2016-011 § 1 (Exh. A) (part), 2016 ; Ord. 2024-008 § 4, 2024 )