For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10.05.095 — Establishment of limits in which cooking under tents is allowed

Municipal Code, City of Yakima, Washington (includes legislation through 10-06-2026) · Yakima Municipal Code § 10.05.095

Corpus is an independent public-information project, not the official City of Yakima website. Stable reference: corpuslaw.us/code/b8d87686-7a9f-4c49-9be6-97b7e7c26511

§ 10.05.095: Establishment of limits in which cooking under tents is allowed.

(1) A tent, for the purposes of this section, shall be defined as a structure, enclosure, canopy or shelter, with or without sidewalls or drops, constructed of fabric or pliable material supported by any manner except by air or the contents that it protects, and which meets the flame propagation performance treatment set forth in Section 3104.2 of the International Fire Code (test method 1 or 2 of NFPA 701), CPAI 84, or California Fire Marshal Seal. (2) All tents with dimensions larger than ten feet by ten feet must conform to labeling and certification which shall be done in accordance with Sections 3104.3 and 3104.4 of the International Fire Code. (3) Cooking under tents shall conform with each of the following requirements: (a) Tents with cooking devices are not allowed to be open to the public; (b) Cooking devices are not allowed to obstruct the exit access, exit or exit discharge; (c) Cooking devices located under tents with side-walls shall have cooking devices located a minimum of three feet from tent walls; (d) Cooking surfaces shall have a minimum vertical clearance of forty-two inches to tent structure when the tent dimensions do not exceed ten feet by ten feet, and a minimum vertical clearance of forty-eight inches when the tent dimensions exceed ten feet by ten feet; (e) All tents with cooking devices shall be separated from other tents and structures by a minimum of five feet; (f) A minimum rated 2A-10BC fire extinguisher shall be located within each tent; (g) If grease-laden vapors are produced, a six-liter class K extinguisher shall be located within the tent; (h) All fire extinguishers shall have an up-to-date annual inspection tag provided by certified personnel; and (i) All compressed gas cylinders shall be restrained to prevent dislodging.

( Ord. 2018-015 § 1, 2018 )

Ask a question about Yakima law

Corpus searches the Yakima sections it holds and shows the ones that match, with their citations. Free, no sign-in.