For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.06.100 — Anchoring systems

Municipal Code, City of Yakima, Washington (includes legislation through 10-06-2026) · Yakima Municipal Code § 11.06.100

Corpus is an independent public-information project, not the official City of Yakima website. Stable reference: corpuslaw.us/code/e22d0a7b-d68d-4490-bce3-4c853055118c

§ 11.06.100: Anchoring systems.

A. All mobile homes, with the exception of mobile homes located in a mobile home park, shall have an anchoring system which shall meet the following requirements: (1) Components of the anchoring system shall have a resistance to weather deterioration that is at least equivalent to that of a zinc coating that is not less than 0.3 ounces of zinc per square foot of coated surface. Cut edges of zinc-coated strapping do not need to be coated. (2) An installer shall install, preload, and adjust a ground anchor in accordance with the anchor manufacturer’s instructions. The installer shall supply a copy of such instructions to the code administration manager or his designee. A ground anchor, when installed, shall be able to resist a working load of three thousand one hundred fifty pounds in the direction of the tie plus a fifty percent overload (four thousand seven hundred twenty-five pounds total) without failure. Failure occurs if the point of connection of a vertical tie to an anchor is withdrawn more than two inches at three thousand one hundred fifty pounds, or when the point of connection of a diagonal tie is moved more than four inches horizontally when a load of three thousand one hundred fifty pounds is applied at forty-five degrees from the horizontal. Ground anchors shall be marked with a manufacturer’s identification and model number in a location that is visible after the anchor is installed. The manufacturer of a ground anchor must provide instructions with each anchor that specify the kind of soil for which the anchor is suitable. (3) In the event concrete slabs or continuous footings are used to transfer the anchoring loads to the ground, the following requirements apply: (a) Steel rods cast in concrete shall be able to resist the loads and corrosion as specified for ground anchors. (b) A deadman anchor may be used in place of a listed anchor. It shall be constructed of solid concrete at least six inches in diameter and two feet long; reinforced with two number four steel rods; and installed at least five feet below the surface of the ground. (c) A concrete slab may be used in place of a ground anchor if it provides holding strength equal to that required for ground anchors. (4) Ties shall be of cable, strapping, or other approved materials. Ties shall be fastened to ground anchors and drawn tight with turnbuckles, yoke fasteners, or other approved tensioning devices. Tension devices shall end in clevis, forged, or welded eyes. Hook ends are not permitted. Tension devices shall be designed to prevent self-disconnection if the tie becomes slack. Cable tie eyes shall be secured with two U-bolt cable clamps or an equivalent approved by the code administration manager or his designee. Tie materials shall resist a working load of three thousand one hundred fifty pounds with no more than two percent elongation, and shall withstand a fifty percent overload (four thousand seven hundred twenty-five pounds total). Ties shall connect the ground anchor to the main frame longitudinal member. Ties shall not connect to steel out-rigger beams that fasten to the main frame, unless the manufacturer’s installation instructions approve the connection. Diagonal ties shall lie at least forty degrees from the vertical. Vertical ties shall be substantially vertical. If a vertical tie is not substantially vertical, the anchor shall be placed outboard of the tie’s connection to the main frame. A cable frame tie shall be connected to the main frame by a five-eighths-inch drop forged eye bolt through a hole drilled in the center of the I-beam web, or by an alternative approved by the code administration manager or his designee. The installer shall reinforce the web if necessary to maintain the strength of the I-beam. The installer shall space the ties as evenly as practical, and shall locate a tie within eight feet of each end of the mobile home. The installer may attach two or more ties to a single ground anchor if the anchor can withstand a total required load. The installer shall install vertical ties at each detached corner of a clerestory roof and of add-on sections of expandable mobile homes.

( Ord. 2894 § 1 (part), 1985 ; Ord. 2925 § 1, 1985 )

Ask a question about Yakima law

Corpus searches the Yakima sections it holds and shows the ones that match, with their citations. Free, no sign-in.