§ 11.40.404.6: Amendment to Section 404.6.
Section 404.6 of the 2018 International Property Maintenance Code is amended to read as follows: 404.6 Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: 1. | A unit occupied by not more than one occupant shall have a minimum clear floor area of 120 square feet (11.2 meters squared). A unit occupied by not more than two occupants shall have a minimum clear floor area of 220 square feet (20.4 meters squared). A unit occupied by three occupants shall have a minimum clear floor area of 320 square feet (29.7 meters squared). These required areas shall be exclusive of the areas required by Items 2 and 3. 2. | The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a minimum clear working space of 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided. 3. | The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. 4. | The maximum number of occupants shall be three. Efficiency units shall not exist independently, but must be part of a single structure or planned development.
( Ord. 2021-004 § 1, 2021 )