§ 15.27.408 — Specific standards
Municipal Code, City of Yakima, Washington (includes legislation through 10-06-2026) · Yakima Municipal Code § 15.27.408
Corpus is an independent public-information project, not the official City of Yakima website. Stable reference: corpuslaw.us/code/f090a2c3-e4c5-4b9c-b3f4-fe01b43405f1
§ 15.27.408: Specific standards.
In all special flood hazard areas where base elevation data has been provided as set forth in YMC § 15.27.400, the following regulations shall apply, in addition to the general standards of YMC § 15.27.407: A. Residential Construction. (See IRC Section 323.2.) 1. In AE and A1-30 zones or other A zones where the BFE has been determined or can be reasonably obtained, new construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated one foot or more above the BFE. Mechanical equipment and utilities shall be waterproofed or elevated at least one foot above the BFE. 2. Fully enclosed areas below the lowest floor that are subject to flooding are prohibited, or shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: a. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided; b. The bottom of all openings shall be no higher than one foot above grade; and c. Openings may be equipped with screens, louvers, or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters. d. A garage attached to a residential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the entry and exit of floodwaters. 3. Residential construction within one hundred feet of a floodway, or the ordinary high water mark if no floodway has been established, shall also meet the requirements of YMC § 15.27.407(C). 4. New construction and substantial improvement of any residential structure in an AO zone shall meet the requirements in subsection H of this section. 5. New construction and substantial improvement of any residential structure in an unnumbered A zone for which a BFE is not available and cannot be reasonably obtained shall be reasonably safe from flooding, but in all cases the lowest floor shall be at least two feet above the highest adjacent grade. B. Nonresidential Construction (44 CFR 60.3(C)(3) and (4)). New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall meet the standards in subsection A of this section; or, together with attendant utility and sanitary facilities, shall: 1. Be dry floodproofed so that below one foot or more above the base flood level the structure is watertight with walls substantially impermeable to the passage of water or dry floodproofed to the elevation required by ASCE 24, whichever is greater; 2. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; 3. Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection based on their development and/or review of the structural design, specifications and plans. Such certifications shall be provided to the official as set forth in YMC § 15.27.437; and 4. Nonresidential structures that are elevated, not floodproofed, must meet the same standards for space below the lowest floor as described in subsection (A)(2) of this section. 5. If located in an unnumbered A zone for which a BFE is not available and cannot be reasonably obtained, the structure shall be reasonably safe from flooding, but in all cases the lowest floor shall be at least two feet above the highest adjacent grade. C. Manufactured Homes. All manufactured homes to be placed or substantially improved on sites shall be elevated on a permanent foundation such that the lowest floor is elevated one foot or more above the base flood elevation, and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement in accordance with subsection A of this section. D. Recreational Vehicles. Recreational vehicles placed on sites are required to either: 1. Be on the site for fewer than one hundred eighty consecutive days; 2. Be fully licensed and ready for highway use, on wheels or jacking system, attached to the site only by quick-disconnect-type utilities and security devices, and have no permanently attached additions; or 3. Meet the anchoring requirements of subsection C of this section. E. Enclosed Area Below the Lowest Floor. If building or manufactured homes are constructed or substantially improved with fully enclosed areas below the lowest floor, the areas shall be used solely for parking of vehicles, building access, or storage. F. Appurtenant Structure (Detached Garages and Small Storage Structures) for A Zones (A, AE, A1-30, AH, AO). 1. Appurtenant structures used solely for parking of vehicles or limited storage may be constructed such that the floor is below the BFE, provided the structure is designed and constructed in accordance with the following requirements: a. Use of the appurtenant structure must be limited to parking of vehicles or limited storage; b. The portions of the appurtenant structure located below the BFE must be built using flood-resistant materials; c. The appurtenant structure must be adequately anchored to prevent flotation, collapse, and lateral movement; d. Any machinery or equipment servicing the appurtenant structure must be elevated or floodproofed to or above the BFE; e. The appurtenant structure must comply with the floodway encroachment provisions in YMC § 15.27.411(B); f. The appurtenant structure must be designed to allow for the automatic entry and exit of floodwaters in accordance with subsection (A)(2) of this section; g. The structure shall have low damage potential; h. If the structure is converted to another use, it must be brought into full compliance with the standards governing such use; and i. The structure shall not be used for human habitation. 2. Detached garages, storage structures, and other appurtenant structures not meeting the above standards must be constructed in accordance with all applicable standards in subsection (A)(1) of this section. 3. Upon completion of the structure, certification that the requirements of this section have been satisfied shall be provided to the floodplain administrator for verification. G. AE and A1-30 Zones with Base Flood Elevations but No Floodways. In areas with BFEs (when a regulatory floodway has not been designated), no new construction, substantial improvements, or other development (including fill) shall be permitted within zones A1-30 and AE on the community’s FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the community. H. Standards for Shallow Flooding Areas (AO Zones). Shallow flooding areas appear on FIRMs as AO zones with depth designations. The base flood depths in these zones range from one to three feet above ground where a clearly defined channel does not exist, or where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is usually characterized as sheet flow. In addition to other provisions in this code, the following additional provisions shall apply in AO zones: 1. New construction and substantial improvements of residential structures and manufactured homes within AO zones shall have the lowest floor (including basement and mechanical equipment) elevated above the highest adjacent grade to the structure, one foot or more above the depth number specified in feet on the community’s FIRM (at least two feet above the highest adjacent grade to the structure if no depth number is specified). 2. New construction and substantial improvements of nonresidential structures within AO zones shall either: a. Have the lowest floor (including basement) elevated above the highest adjacent grade of the building site, one foot or more above the depth number specified on the FIRM (at least two feet if no depth number is specified); or b. Together with attendant utility and sanitary facilities, be completely floodproofed to or above that level so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. If this method is used, compliance shall be certified by a registered professional engineer, or architect as in subsection (B)(3) of this section. 3. Require adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. 4. Recreational vehicles placed on sites within AO zones on the community’s FIRM either: a. Be on the site for fewer than one hundred eighty consecutive days; or b. Be fully licensed and ready for highway use, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and have no permanently attached additions; or c. Meet the requirements of subsections (H)(1) and (3) of this section and the anchoring requirements for manufactured homes (YMC § 15.27.407(A).
( Ord. 2008-46 § 1 (part), 2008 ; Ord. 2016-029 § 1 (Exh. A) (part), 2016 ; Ord. 2017-017 § 2 (Exh. B) (part), 2017 ; Ord. 2021-021 § 2 (Exh. A), 2021 )
Ask a question about Yakima law
Corpus searches the Yakima sections it holds and shows the ones that match, with their citations. Free, no sign-in.