§ 44-1193 — Standards for development in the floodfringe
Municipal Code, City of Green Bay, Wisconsin (Supp. 10: codified through Ordinance No. 11-26, enacted July 21, 2026 (online updated October 12, 2026)) · Green Bay Municipal Code § 44-1193
Corpus is an independent public-information project, not the official City of Green Bay website. Stable reference: corpuslaw.us/code/4057378c-a5cb-474e-83cb-4c9b8c70aac8
Sec. 44-1193. - Standards for development in the floodfringe.
In addition to all of the general provisions from Division 2 of this article, the following requirements shall apply to development in the floodfringe according to the use requested. Any existing structure in the floodfringe must meet the nonconforming use requirements of Division 9 of this article. (1) Residential uses. Any structure, including a manufactured home, which is to be newly constructed or moved into the floodfringe shall meet or exceed the following standards. Any existing structure in the floodfringe must meet the requirements of Division 9 Nonconforming Uses; a. All new construction, including placement of manufactured homes, and substantial improvement of residential structures, shall have the lowest floor elevated to or above the flood protection elevation on fill. The fill around the structure shall be one foot or more above the regional flood elevation extending at least 15 feet beyond the limits of the structure. No area may be removed from the floodfringe district unless it can be shown to meet Section 44-1106. b. Notwithstanding subsection a. above, a basement or crawlspace floor may be placed one foot above the regional flood elevation if the basement or crawlspace is designed to make all portions of the structure below the flood protection elevation watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. No floor of any kind is allowed lower than one foot above the regional flood elevation. c. Contiguous dryland access shall be provided from a structure to land outside of the floodplain, except as provided in subsection (d). d. In developments where existing street or sewer line elevations make compliance with subsection (c) impractical, the City may permit new development and substantial improvements where roads are below the regional flood elevation, provided that at least one of the following criteria is satisfied. 1. The City has written assurance from police, fire, and emergency services that rescue and relief will be provided to the structure(s) by wheeled vehicles during a regional flood event; or 2. The City has a DNR-approved emergency evacuation plan that follows acceptable hazard mitigation planning guidelines. (2) Accessory structures or uses. In addition to all of the general provisions from Division 2 of this article, new construction and substantial improvements of accessory structures shall be constructed on fill with the lowest floor at or above the regional flood elevation. (3) Commercial uses. In addition to all of the general provisions from Division 2 of this article, any commercial structure which is erected, altered, or moved into the floodfringe shall meet or exceed the standards for residential uses under subsection (1). Subject to the requirements of subsection (5), storage yards, surface parking lots, and other such uses may be placed at lower elevations if an adequate warning system exists to protect life and property. (4) Manufacturing and industrial uses. In addition to all of the general provisions from Division 2 of this article, any manufacturing or industrial structure which is erected, altered, or moved into the floodfringe shall have the lowest floor elevated to or above the flood protection elevation or meet the floodproofing standards in Section 44-1283. Subject to the requirements of subsection (5), storage yards, surface parking lots, and other such uses may be placed at lower elevations if an adequate warning system exists to protect life and property. (5) Storage of materials. Materials that are buoyant, flammable, explosive, or injurious to property, water quality, or human, animal, plant, fish, or aquatic life shall be stored at or above the flood protection elevation or floodproofed in compliance with Section 44-1283. Adequate measures shall be taken to ensure that such materials will not enter the water body during flooding. (6) Public utilities, streets, and bridges. All utilities, streets, and bridges shall be designed to be compatible with comprehensive floodplain development plans. a. When failure of public utilities, streets, and bridges would endanger public health or safety, or where such facilities are deemed essential, construction or repair of such facilities shall only be permitted if they are designed to comply with Section 44-1283. b. Minor roads or non-essential utilities may be constructed at lower elevations if they are designed to withstand flood forces to the regional flood elevation. (7) Sewage systems. All sewage disposal systems shall be designed to minimize or eliminate infiltration of flood water into the system, in accordance with Section 44-1283(c), to the flood protection elevation and shall meet the provisions of all local ordinances and Wis. Admin. Code SPS ch. 383. (8) Wells. All wells shall be designed to minimize or eliminate infiltration of flood waters into the system, in accordance with Section 44-1283(c), to the flood protection elevation and shall meet the provisions of Wis. Admin. Code NR Chs. 811 and 812. (9) Solid waste disposal sites. Disposal of solid or hazardous waste is prohibited in floodfringe areas. (10) Deposition of materials. Any deposited material must meet all the provisions of this article. (11) Manufactured homes. a. Owners or operators of all manufactured home parks and subdivisions shall provide adequate surface drainage to minimize flood damage and prepare, secure approval of, and file an evacuation plan indicating vehicular access and escape routes with local emergency management authorities. b. In existing manufactured home parks, all new homes, replacement homes on existing pads, and substantially improved homes shall satisfy the following criteria. 1. The lowest floor shall be elevated to the flood protection elevation. 2. The homes shall be anchored so they do not float, collapse, or move laterally during a flood. c. Outside of existing manufactured home parks, including new manufactured home parks and all single units outside of existing parks, all new, replacement, and substantially improved manufactured homes shall meet the residential development standards for the floodfringe subsection (1). (12) Mobile recreational vehicles. All mobile recreational vehicles must be on site for fewer than 180 consecutive days and satisfy one of the following requirements. (a) The vehicle is fully licensed, if required, and ready for highway use. (b) The vehicle meets the elevation and anchoring requirements in subsection (11).
(Ord. No. 05-23, § 1, 3-21-2023)
Ask a question about Green Bay law
Corpus searches the Green Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.