Sec. 44-1223. - Standards for development in the general floodplain district.
Division 5 applies to floodway areas, determined pursuant to Section 44-1224; Division 6 applies to floodfringe areas, determined pursuant to Section 44-1224. (1) New construction and substantial improvement of structures in zone AO shall have the lowest floor, including basement, elevated to or above one of the following. a. The depth, in feet, as shown on the FIRM, above the highest adjacent natural grade, plus one additional foot of freeboard; or b. If the depth is not specified on the FIRM, three feet above the highest adjacent natural grade. (2) New construction and substantial improvement of structures in zone AH shall have the lowest floor, including basement, elevated to or above the flood protection elevation. (3) In zones AO and AH, all new construction and substantial improvement of structures shall provide adequate drainage paths to guide floodwaters around structures. (4) All development in zones AO and AH shall meet the requirements applicable to floodfringe areas in Division 6.
(Ord. No. 05-23, § 1, 3-21-2023)