§ 44-1626 — Standards
Municipal Code, City of Green Bay, Wisconsin (Supp. 10: codified through Ordinance No. 11-26, enacted July 21, 2026 (online updated October 12, 2026)) · Green Bay Municipal Code § 44-1626
Corpus is an independent public-information project, not the official City of Green Bay website. Stable reference: corpuslaw.us/code/9768464d-a9a4-4af0-b219-4fb08758daca
Sec. 44-1626. - Standards.
(a) Multiple freestanding or roof-mounted wind energy systems may be permitted per parcel under a conditional use permit compliant with Article II of this chapter. (b) Met towers shall be permitted under the same standards, permit requirements, permit and abandonment procedures as a small wind energy system. (c) Height limitations. (1) The overall height of any freestanding small wind energy system may be permitted to supersede zoning district height standards but shall not exceed 170 feet in total height. (2) Roof-mounted wind energy systems shall be integrated, to the extent possible, into the design of the structure that it is being attached to and shall not exceed the height requirement of the zoning district. (d) Setbacks. A wind tower for a small wind system shall be set back a distance equal to its total height from: (1) Any public road right-of-way, unless written permission is granted by the governmental entity with jurisdiction over the road; (2) Any overhead utility lines, unless written permission is granted by the affected utility; (3) All property lines within residentially zoned districts. (4) All property lines within or adjacent to commercial or industrial zoned areas, unless written permission granted from the affected property owners. (e) Sound/noise level. On-site small wind energy systems shall comply with Chapter 24 of this Code. Sound pressure levels may be exceeded during short-term events such as utility outages and/or severe wind storms. All small wind energy systems shall be equipped with both manual and automatic controls to limit the rotational speed of the blade within the design limits of the rotor. (f) Access. (1) All ground-mounted electrical and control equipment shall be labeled or secured to prevent unauthorized access. (2) The tower shall be designed and installed so as to not provide step bolts or a ladder readily accessible to the public at a minimum height of eight feet above the ground. (g) Electrical wires. All electrical wires associated with a small wind energy system, other than wires necessary to connect the wind generator to the tower wiring, the tower wiring to the disconnect junction box, and the grounding wires, shall be located underground. (h) Lighting. A wind tower and generator shall not be artificially lighted unless such lighting is required by the Federal Aviation Administration. (i) Appearance, color, and finish. The wind generator and tower shall remain painted or finished in the color or finish that was originally applied by the manufacturer, unless approved in the building permit. All portions of the wind energy system shall be a non-reflective, non-obtrusive color. Only monopole towers are permitted. The appearance of the turbine, tower and any other related components shall be maintained throughout the life of the wind energy system pursuant to industry standards. (j) Shadow flicker. Small wind energy systems shall be sited in a manner that does not result in significant shadow flicker impacts. The applicant has the burden of proving that the shadow flicker will not have significant adverse impact on neighboring or adjacent uses. Potential shadow flicker will be addressed either through siting or mitigation measures. (k) Signs. All signs shall be prohibited, other than the manufacturer's or installer's identification, appropriate warning signs, or owner identification on a wind generator, tower, building, or other structure associated with a small wind energy system visible from any public road shall be prohibited. Systems shall not be used for displaying any advertising. (l) The applicant shall notice Eagle III Rescue of any freestanding small wind energy system. (m) All small wind energy system towers more than 50 feet tall require a height permit from the Airport Director. (n) Before construction, the applicant shall check to determine if the proposal meets the reporting criteria of 14 CFR 77.13; and if required, notify the Federal Aviation Administration (FAA) using their Obstruction Evaluation/airport Airspace Analysis (OE/AAA) website. If the proposal meets FAA reporting criteria, the City of Green Bay will table action on approving the proposal until the FAA airspace study is complete, and the FAA has issued a final letter of determination of no hazard to air navigation. (o) Code compliance. (1) A small wind energy system including tower shall comply with all applicable state construction and electrical codes, and the National Electrical Code. (2) Small wind energy systems that connect to the electric utility shall comply with Wis. Admin. Code Ch. PSC 119, Rules for Interconnecting Distributed Generation Facilities.
(Code 1984, § 13.1610(a); Ord. No. 1-11)
Ask a question about Green Bay law
Corpus searches the Green Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.
