For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-166 — Minimum building elevations

Municipal Code, City of Green Bay, Wisconsin (Supp. 10: codified through Ordinance No. 11-26, enacted July 21, 2026 (online updated October 12, 2026)) · Green Bay Municipal Code § 8-166

Corpus is an independent public-information project, not the official City of Green Bay website. Stable reference: corpuslaw.us/code/0efd2bfb-7122-4a44-b3ad-3592cef0b729

Sec. 8-166. - Minimum building elevations.

(a) The first habitable floor of any building or structure shall not be constructed below the current City elevation. (b) Uses requiring floodproofing measures shall be designed consistent with the current flood protection elevation. The Director shall require that the applicant submit a plan or document certified by a registered professional engineer or architect that the floodproofing measures are consistent with the flood protection elevation. Floodproofing measures shall include, but are not limited to, the following: (1) Installation of water-tight doors, bulkheads, and shutters. (2) Reinforcement of walls to resist water pressure. (3) Use of paint, membrane, or mortar to reduce seepage of water through walls. (4) Construction of water supply and waste treatment systems to prevent the entrance of floodwaters. (5) Pumping facilities for subsurface drainage systems for buildings, to receive external foundation wall and basement floor pressures. (6) Construction to resist rupture or collapse caused by water pressure or floating debris. (7) Installation of cutoff (backwater) valves on sewer lines or elimination of gravity flow basement drains. (8) Anchorage to resist flotation and lateral movement. (9) Addition of mass or weights to structures to resist flotation. (10) Installation of pumps to lower water levels in structures. (c) Accessory uses such as parking lots, yards, and other similar land or open land uses may be permitted at the current base flood elevation. (d) Fill shall be placed around buildings and structures to a minimum of one foot above base flood elevation and shall extend at such elevation at least 15 feet in each direction from the structure thereon. Fill material shall be stabilized in a manner recommended by the U.S. Soil Conservation Service and protected against erosion.

(Ord. No. 13-24, § 1, 7-30-2024)

Ask a question about Green Bay law

Corpus searches the Green Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.