§ 8-594 — Minimum standards for light, heating, and ventilation
Municipal Code, City of Green Bay, Wisconsin (Supp. 10: codified through Ordinance No. 11-26, enacted July 21, 2026 (online updated October 12, 2026)) · Green Bay Municipal Code § 8-594
Corpus is an independent public-information project, not the official City of Green Bay website. Stable reference: corpuslaw.us/code/4c4f6fbc-a3f0-4664-b5b2-dd7262fd4020
Sec. 8-594. - Minimum standards for light, heating, and ventilation.
(a) Window area. Every habitable room, toilet room, and bathroom shall have at least one window facing directly to the outdoors. The minimum window area shall be at least ten percent of the floor area of the room, but not less than 12 square feet. The top of at least one such window shall be not less than 6½ feet above the floor. At least one-half of the window shall be made so as to open the full width unless other means of adequately ventilating such rooms are installed and operating. The outside window in every toilet or bathroom shall have a total area of at least ten percent of the floor area, but not less than four square feet, provided no window or sky light shall be required in adequately ventilated bathrooms or toilet rooms equipped with a ventilation system which is kept in continuous operation. (b) Electric equipment. In accordance with Wis. Admin. Code SPS §§ 316.020 and 316.021, all electrical power and communication equipment shall be properly constructed, installed, operated, and maintained. Any of this equipment known to be defective shall be promptly repaired or isolated until repairs can be made. (c) Heating facilities. (1) Every dwelling unit shall have supplied heating facilities; and such facilities shall be properly installed, maintained in good working condition, and capable of adequately heating all habitable rooms, bathrooms, and toilet rooms contained therein or intended for use by the occupants thereof to a temperature of at least 68 degrees Fahrenheit, measured three feet above the floor level, when the outside temperature is at or above −15 degrees Fahrenheit. A dwelling unit shall contain a sufficient number of chimney outlets to permit the occupants, through the use of unit heaters furnished by the owner, to adequately heat all habitable rooms, bathrooms, and toilet rooms contained therein to a temperature of at least 68 degrees Fahrenheit, measured at least three feet above the floor level, when the outdoor temperature is at or above negative −15 degrees Fahrenheit. This provision shall not be interpreted to permit the use of portable heaters where such use is prohibited by either the City Building or Heating and Air Conditioning Code or the State Building or Heating, Ventilating and Air Conditioning Codes, as applicable. Every central heating system shall comply with the City Building and Heating and Air Conditioning Codes and the State Building and Heating, Ventilating and Air Conditioning Codes, as applicable. Such central heating systems shall also comply with the following requirements: a. The central heating unit shall be in good operating condition. b. Every heat duct, steam pipe, and hot water pipe shall be free of leaks and shall function so that an adequate amount of heat is delivered where intended. c. Every seal between the sections of a warm air furnace shall be tight, so noxious gases will not escape into heat ducts. d. If the temperature of all dwelling units in a multi-unit dwelling is regulated by a single heating zone controlled by a single device, and the temperature standards articulated in this section cannot be maintained in any of the dwelling units included in that zone, the Director may issue orders to remedy the deficiency, including but not limited to requiring additional heating zones in the dwelling. (2) Every unit heater shall comply with the City Building and Heating and Air Conditioning Codes and the State Building and Heating, Ventilating, and Air Conditioning Codes, as applicable, and with all of the following requirements: a. No unit heater burning solid, liquid, or gaseous fuels shall be a portable type. b. Every unit heater burning solid, liquid, or gaseous fuels shall be properly vented. c. Every coal-burning or oil-burning unit heater shall have a fire-resistant panel beneath it. d. The location of unit heaters, the insulation of walls and ceilings close to such heaters, and the construction, installation, and guarding of smoke pipes and walls or ceilings through which they go shall be in accordance with the Heating and Air Conditioning Code of the City in Article V of this chapter. (d) Lighting of public halls and stairways. Every public hall and public stairway in every dwelling containing four or more dwelling units or accommodating more than 20 persons shall be adequately lighted at all times. Such lighting shall include lights at all intersections of stairways. Instead of continuous lighting, every public hall and public stairway in dwellings containing fewer than four dwelling units or rooming houses accommodating more than three roomers but less than 20 persons shall be supplied with convenient light switches controlling an adequate lighting system which may be turned on when needed. (e) Screens. At least one window in each habitable room, toilet room, and bathroom where windows are required shall be supplied with a screen covering at least one-third of the window area, except where other means of adequately ventilating such rooms are available and operating. Screens shall have a wire mesh of not less than No. 16, and all installed screens must be in a state of good repair. (1) Exception. During the cold weather period from November 1 to March 31 of each calendar year, having screens installed is optional. Any screens installed must be in a state of good repair. (f) Basement window screens. Every basement or cellar window used or intended to be used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or such other device as will effectively prevent their entrance.
(Ord. No. 13-24, § 1, 7-30-2024)
Ask a question about Green Bay law
Corpus searches the Green Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.