Sec. 10-126. - Gas conversion burners.

(a) Before any gas conversion burner is installed, the combustion chamber flue passages, smokepipe, and the chimney shall be thoroughly cleaned of all rust, soot and dirt. All rust and scale shall be scraped from the edges of the firing clinker or cleanout doors, and the door jambs to obtain a tight fit. Leaky joints on cast iron furnaces shall be recemented. A smoke or other test shall be used to determine the effectiveness of the repairs. All doors on the boiler or furnace, except the firing door, shall be tightly sealed. The slots in the firing door shall be sealed. The fire brick in steel warm air furnaces shall be removed except where it is the only material that forms the sides of the fire pot. (b) The firing door on the furnace or boiler shall be arranged to open easily to relieve pressure by filing or removing the door catch and providing a spring device to hold the door closed. (c) Where a horizontal (in-shot) type gas conversion burner is installed in the ash pit of a dry base boiler or gravity warm air furnace, the ash pit shall be lined on the bottom and the sides up to the grate level with two inches of insulating firebrick or other approved insulation. (d) Movable smoke pipe dampers shall be removed. Other dampers which are an integral part of the boiler or furnace shall be removed or permanently locked in a position which does not interfere with the operation of the burner. (e) In down draft or revertible flue-type furnaces or boilers in which the flue passage turns downward after leaving the combustion chamber, the top of the combustion chamber, of flue passage shall be vented to the smoke pipe by a one-inch diameter or larger pipe. The relief opening of a vertical or horizontal draft diverter should be at least one foot higher than the highest flue passage. (f) Where a bypass to the smoke pipe is provided in the construction of the furnace of the boiler at the point where the flue turns downward, the damper in the bypass may be partially opened and locked in place in lieu of the required one-inch pipe. (g) The cross sectional area of the flue or vent connector shall be not less than one square inch per 7,500 BTU per hour input of the gas conversion burner, but in no case shall the diameter of the flue or vent connector be less than that of the appliance flue collar. (h) The draft diverter shall be located in the same room as the appliance.

(Code 1976, § 15.04.060)

Ask a question about Janesville law

Corpus searches the Janesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.