Sec. 40-502. - Applicability and prohibitions.
(a) Fats, oils, grease, and sand interceptors are necessary and shall be installed, maintained, and used by every commercial and industrial property owner and possessor, and each POTW user in the City, unless specifically exempt by the control authority, for the proper handling of wastewater containing excessive amount of FOG or sand; except that such interceptors shall not be required for residential users. All interceptor units shall be of a type and capacity approved by the POTW control authority, City Plumbing Inspector or the State of Wisconsin, and shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and repaired by the user at their expense. (b) All commercial and industrial properties, POTW users, and plumbing installations, other than residential dwelling units, where FOG or similar waste products of cooking or food are introduced into the POTW shall provide interceptors in accordance with this article and other applicable laws and regulations. All drains and drain piping carrying FOG shall be directed through one or more interceptors in accordance with the state and City plumbing code. (c) Notwithstanding the state and City plumbing codes, every new commercial and industrial property and POTW user plumbing system which discharges to the POTW shall be provided with one or more grease and/or sand interceptors. (1) Altered or remodeled plumbing systems. Notwithstanding the state and City plumbing codes, every existing commercial and industrial property and POTW user plumbing system that discharges to the POTW which is altered or remodeled as to that part of the plumbing system which discharges from kitchens or food processing area shall be provided with one or more approved interceptors. (2) Existing installations. The POTW control authority or City Plumbing Inspector may require the installation of a grease or sand interceptor for existing plumbing installations where the waterway of a drain system or sewer system is reduced or filled due to sand or congealed grease, or where sand or congealed grease impairs the proper functioning or the sewer system. (3) Exterior grease interceptors shall receive the entire waste discharge from kitchens or food processing areas. Every exterior interceptor shall be designed, constructed, and installed in accordance with the standards contained in the state and City plumbing codes, as from time to time amended or renumbered. (4) No POTW user may intentionally or unintentionally allow the direct or indirect discharge of any FOG of animal or vegetable origin into the POTW system in such amount as to cause interference and/or harm of any kind with or to the City wastewater collection or treatment system, or as to cause one or more pollutants to pass through the treatment works into the environment. (5) All users with a grease and/or sand interceptor must adhere to all the requirements, procedures, and detailed recordkeeping to ensure compliance with the requirements of this article. All users shall maintain such records for not less than seven years and every user shall render the records available for inspection by a representative of the POTW during normal business hours. An accurate, complete, and daily updated maintenance log shall be kept by every user that indicates, at a minimum: a. Date the interceptor was serviced. b. Name of person or company servicing the interceptor. c. Method of cleaning. d. Disposal method of FOG or sand. (6) Cleaning schedules. a. Grease and sand interceptors shall be cleaned as often as necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the interceptor; to ensure the discharge is in compliance with local discharge limits as identified in Section 40-173(d)(3); and so that no visible grease is observed in the discharge. b. Grease interceptors shall be completely evacuated every 30 days, or more frequently when: 1. 25 percent or more of wetted height of the grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, fats, oils, or greases; or 2. The discharge exceeds BOD, TSS, FOG, PH, or other pollutant levels established by the POTW; or if there is a history of noncompliance. (7) Any person who owns or operates a grease interceptor may submit to the POTW a request in writing for an exception to the 30, day cleaning frequency of their grease interceptor. The POTW may grant an extension for required cleaning frequency on a case-by-case basis when: a. The grease interceptor owner/operator has demonstrated that the specific interceptor shall produce an effluent, based on defensible analytical results, in consistent compliance with established local discharge limits such as BOD, TSS, FOG, and other parameters as determined by the POTW; or b. Less than 25 percent of the wetted height of the grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, fats, oils, or greases. (8) Prohibited practices. No person shall introduce, permit, or cause the introduction of any surfactant, solvent, or emulsifier into a grease interceptor. Surfactants, solvents, and emulsifiers are materials which allow the grease to pass from the grease interceptor into the collection system and include, but are not limited to, enzymes, soap, diesel, kerosene terrene, and other solvents.
(Code 1976, § 13.17.030; Ord. No. 2020-798, § 6, 8-24-2020)
Ask a question about Janesville law
Corpus searches the Janesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.