For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.07 — Development Standards

Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Zoning Ordinance § 14.07

Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/204dd0e5-ce7d-4a2e-83fe-aed3718a3ee1

14.07. - Development Standards.

To establish and define criteria for the review process set forth in this Ordinance, the following Development Standards for all uses requiring Site Plan Review are created. A. General Provisions. 1. The development standards provided herein are minimum standards and additional standards or conditions may be required for individual developments when the circumstances warrant. 2. Should the development standards conflict with any other provision of the Ordinance, the most restrictive provision shall apply. 3. The Development Plans shall serve as the review documents which the Review Authority will use in the analysis of the application for Site Plan Review. B. Building Plans. Building Plans shall show and include: 1. Design and Architecture of Buildings. Elevation shall be provided and dimensioned. Plans shall be drawn to sufficient detail so that all room sizes, wall openings, building projections and locations of all exterior HVAC and utility services equipment can be identified. 2. Materials and colors of exterior surfaces such as walls, roofs, and window trim shall be indicated. 3. Details on fire detection, fire alarm and other safety devices, including fire suppression, sprinkler, standpipe, and restaurant hood suppression systems shall be provided for review and be approved by the Kenosha Fire Department. 4. Building size and scale should reflect the physical scale of the surrounding area and the scale of surrounding buildings. 5. The location and orientation of building elements, such as balconies or porches, should reflect the orientation of surrounding buildings and structures. 6. Rooms used for residential purposes shall provide adequate living area, as required in the Minimum Housing Code of the Code of General Ordinances. 7. The materials and design of buildings, structures and additions should complement the surrounding area. 8. Building design shall be in compliance with the Americans With Disability Act. 9. Building address shall be clearly displayed on building. 10. Commercially and institutionally used buildings authorized to be constructed within the City shall conform with the design guidelines hereinafter set forth: a. Building faces of all commercially and institutionally used principal buildings shall be constructed primarily of architectural masonry, wood, glass or a combination of these materials. The previous sentence notwithstanding, architectural metal panels may be used as a secondary material on a face of a principal building, if the percentage of the face covered by the architectural metal panels is less than the percentage of the face covered by at least one (1) of the materials identified in the previous sentence, and also if such use is pursuant to plans approved by the Review Authority illustrating the design in a manner such that the relative percentages of material used for the face may be determined. Subject to design requirements of other ordinance sections, building faces of all commercially and institutionally used accessory buildings must be constructed of architectural masonry, wood, glass, architectural metal panels or a combination of these materials in any proportion. Ribbed or corrugated metal siding shall not be permitted on any building face. Smooth face concrete blocks shall not be permitted on any building face, except when used for accent banding, which shall not be wider than three (3) adjacent courses and not more than six (6) courses on any building face. Exterior Insulated Finish Systems (EIFS) shall only be allowed on the first floor of any building as an accent material above a window, entrance or other similar architectural feature. Exterior Insulated Finish Systems shall be allowed as a primary material above the first floor. b. Split-faced or decorative concrete block shall not be painted or stained after installation without the approval of the Review Authority. c. Articulation on the rooflines shall be provided by using a pitched roof, a partial roof or parapet walls with a minimum height difference of two (2) feet. d. Rooftop mechanicals shall be concealed in order to prevent their visibility from grade level as measured from the lot lines and abutting street rights-of-way. Rooftop mechanical screening shall be compatible with the design, color and materials of the building(s). e. Materials and colors of buildings within a Unified Business District or Large Scale Commercial Development shall be consistent among all building(s). f. Articulation of building façades shall comply with the following design standards: (1) Recesses and/or projections shall comprise at least twenty (20) percent of each façade length, with articulation as deemed acceptable by the Review Authority such as false windows or articulation of materials. In no event shall an uninterrupted façade extend more than one hundred (100) feet. (2) Windows, awnings, arcades or similar architectural elements deemed acceptable by the Review Authority shall total at least sixty (60) percent of each façade length which faces a public street or private street. (3) The principal entrance to a commercial, office or institutional building in the B-4 District shall be required to have: (a) Ornamentation around the door; and (b) At least one (1) of the following: recessed entrance (recessed at least three (3) feet); protruding entrance (protruding at least three (3) feet); canopy (extending at least five (5) feet); portico (extending at least five (5) feet); or an overhang (extending at least five (5) feet). g. Metal roofs and/or awnings shall only be permitted when the roofing material meets the minimum standards of the International Building Code. 11. Multifamily buildings authorized to be constructed within the City shall conform with the exterior building variation guidelines hereinafter set forth: a. Exterior building variation is required on multifamily buildings that contain eight (8) or more units. One-quarter (¼) of units within the building shall differ from the other units by symmetrically changing the location, pattern or form of at least two (2) of the following architectural elements: (1) Balconies, porches or verandas; (2) Window type and fenestration; (3) Roof pitch or design; (4) Exterior materials; (5) Height; (6) Change in material and/or color in a vertical bay; (7) Other exterior building modifications approved by the Review Authority. b. Each building in a multifamily development that consists of two (2) or more buildings shall differ from each adjacent and facing building by using at least two (2) of the following criteria: (1) Shifted building orientations of at least forty-five (45) degrees between buildings; (2) Façade width, height, and symmetry; (3) Roof pitch or design; (4) Total number, type, or symmetrical location of doors, windows, or architectural properties and the exterior building materials; (5) Architectural relief of buildings; i.e., dormers, porches; (6) Change in material and/or color in a vertical bay; (7) Other exterior building modifications approved by the Review Authority. c. Front facing attached garage entrance doors on multifamily buildings shall be no closer to the lot line than the façade of the principal building. This requirement applies to elevations that are abutting a public street or private street. d. Detached garages of multifamily buildings shall be constructed entirely of architectural masonry. The materials on the detached garages shall be compatible with the materials used on the primary buildings. e. Building faces of all multifamily buildings shall be constructed entirely of architectural masonry and/or glass. The previous sentence notwithstanding, architectural metal panels with concealed fasteners may be used as a tertiary material on a face of a multifamily building, if the percentage of the face covered by the architectural metal panels is less than the percentage of the face covered by architectural masonry and is less than the percentage of the face covered by glass, if such use is pursuant to plans approved by the Review Authority illustrating the design in a manner such that the relative percentages of material used for the face may be determined. Architectural metal panels shall only be allowed on the first floor of any building as an accent material above a window, entrance or other similar architectural feature. 12. Industrial buildings authorized to be constructed within the City shall conform with the design guidelines hereinafter set forth: a. Building exteriors of all new industrial buildings shall be constructed entirely of architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass, or any combination of these materials. Other decorative and textured materials may also be used to meet these requirements when authorized by the City Plan Commission. Aviation related buildings located at the Kenosha Regional Airport are exempt from these requirements. b. Additions to industrial buildings shall be constructed entirely with materials that are comparable with the materials of the existing building. On an existing industrial building that does not have architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass, or any combination of these materials on a minimum of two-thirds (⅔) of the exterior of any side which abuts a public street or residential district, building additions shall comply with the following requirements: (1) Any addition to an existing building which creates an exterior side which abuts a public street or a residential district shall consist of architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass, or any combination of these materials on a minimum of the lower two-thirds (⅔) of the building exterior sides of both the addition and existing building which abuts a public street or a residential district. Exceptions to the two-thirds (⅔) requirement for any existing building exterior side which abuts a public street or residential district that has less than two-thirds (⅔), but at least one-third (⅓) architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass or any combination of these materials, may be granted when so authorized by the City Plan Commission. (2) Any additions to existing buildings which are subject to the requirements of Paragraph 12.b.(1) above, and have an exterior side which abuts an interior side lot line and is adjacent to the front exterior shall be constructed with architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass, or any combination of these materials on the lower two-thirds (⅔) of the building exterior for a minimum of twenty (20) feet from the building front or to a natural dividing point approved by the City Plan Department. Exceptions to the twenty (20) foot requirement for any existing building exterior side which abuts an interior side lot line and is adjacent to the front exterior that has less than two-thirds (⅔), but at least one-third (⅓) architectural masonry, Exterior Insulated Finish System, architectural composite aluminum or steel panels, glass or any combination of these materials on the front twenty (20) feet may be granted when so authorized by the City Plan Commission. C. Site Plans. Site Plans shall show and include: 1. Dimensions of the development site, indicated along the property line. Distances to all buildings, structures and freestanding signs, on adjoining properties and building setbacks shall be indicated. 2. The location, footprint and outside dimensions of buildings, structures, and freestanding signs. 3. Existing and proposed pedestrian and vehicular access points, streets, drives, alleys, bicycle paths, bridges, intersections, and other pedestrian and vehicular circulation elements, labeled with street names, dimensioned in feet and tenth and hundredths, and with surface materials identified; i.e., asphalt, sod, etc. 4. Vehicle accommodation areas (including parking areas, loading areas, and circulation areas), with the surface material identified and showing the layout of parking spaces and direction of travel lanes, aisles, or driveways. 5. Front, side, and rear yards, labeled as such and dimensioned. 6. Location and dimensions of all existing or planned easements, lands subject to deed restrictions or protective covenants, rights-of-way, and required emergency accessways. 7. Identification of all land to be dedicated or reserved for public use, with the use named. 8. The location, elevation and dimensions of walls and fences that are to be permanent improvements to the site or erected temporarily during construction. 9. The location, elevation and dimensions of outdoor lighting fixtures, if any. 10. With respect to construction of two hundred fifty thousand (250,000) square feet, or greater, of building development or expansion on a single parcel or contiguous group of parcels, a three-dimensional model or other depiction or color rendering of proposed buildings, the site, and its immediate vicinity. This model shall be at a minimum scale of one (1) inch equals fifty (50) feet. It shall show all proposed buildings, roads, vehicular and pedestrian circulation elements, parking lots or parking structures, existing vegetation to remain, proposed landscaping, and any other significant natural features. 11. A legal description and certified survey of the property. Any easement, covenant or right-of-way, existing or planned, which creates site design constraints shall be indicated. Any design adjustments to these constraints shall not adversely impact the intent of these standards or the provisions of this ordinance. Location of any floodplain, wetland, and shoreland boundary shall be shown. 12. The location, proportion, and orientation of buildings or structures should compliment the location, proportion and orientation of surrounding land forms, buildings or structures. 13. Surrounding Land Uses and Respective Zoning Classifications. The Review Authority shall consider the impact of the proposed development on the comprehensive plan, any neighborhood plan, and the Official Zoning Map, as amended. The Review Authority shall use the following criteria when assessing the development's impact on surrounding land uses: the development shall be consistent with the objectives of the comprehensive plan, and any relevant neighborhood plan, the development shall be compatible with the character and objectives of the zoning district or districts within which it is located, and the development shall be compatible with the character of the neighborhood which surrounds the development. 14. Site access governed by the following criteria: a. Site entrance drive dimensions such as widths, radii and visibility triangles. b. Development shall provide the least number of ingress/egress points along a street necessary for safe and efficient traffic flow. A minimum separation of three hundred (300) linear feet of street frontage shall be required, except that each development or parcel shall be allowed at least one (1) ingress/egress location, or access via cross access easements, through adjoining property. The location of all access points shall be determined by the Review Authority. c. Individual development vehicular entrances shall be at least one hundred twenty-five (125) feet apart. d. Vehicular entrances shall follow the recommended safety guidelines established by the Wisconsin Department of Transportation. e. An adequate internal stacking distance, as deemed to be safe by the City Traffic Engineer, shall be provided from the property line at each entrance. f. Appropriate traffic control measures including signs, crosswalks, etc. shall be utilized at all entrances to public rights-of-way. g. Adjacent development shall share a common entrance drive, where possible. h. Access to adjoining sites shall be coordinated, where possible. (1) At least one (1) vehicular and pedestrian access point to each adjoining site shall be granted by cross easements. (2) Cross access easements should not occur within interior lawn parks. (3) Cross access easements shall be a minimum of thirty (30) feet wide. (4) Cross access easements are encouraged behind buildings to encourage linked rear parking areas. (a) Vehicular access to any nonresidential structure, use, parking or loading facility shall not be gained across land zoned for a residential use, except where authorized by the Review Authority, with due consideration to special circumstances. 15. Parking Lots and Parking Structures. This Section sets forth standards for the design of parking areas in a manner that will reduce the negative visual impacts of large expanses of impervious surface while maintaining maximum safety standards. In addition to these standards, parking lot layout shall conform with Section 5.08 of the Code of General Ordinances, "Parking Facilities." a. Layout. (1) Building entrances shall be accessible from adjacent parking areas by means of a minimum five-foot wide paved walkway, as shown on Figure 1. (2) Parking adjacent to the front of buildings, except within the B-3 districts, shall maintain a seven-foot separation from the building to accommodate pedestrian circulation. b. Parking Lot Design. (1) Parking lots shall be designed and constructed in accordance with Section 5.08 of the Code of General Ordinances, "Parking Facilities." (2) Parking lots shall be paved with asphaltic concrete or Portland cement concrete. 16. Traffic Circulation. Clear and identifiable patterns of circulation are critical to minimizing potentially dangerous conflicts between pedestrian, automobile, and truck traffic. The intent of this Section is to establish standards which create a separation of noncompatible traffic, and create patterns that are clearly oriented to the needs of each, to minimize conflict. a. Pedestrian Access. (1) There shall be a minimum of a five-foot wide paved walkway provided to each building entrance from parking areas and from public sidewalks. (2) Pedestrian walkways shall be provided for access to adjacent properties and be handicap accessible. (3) Drainage improvements shall not pass over pedestrian walks. (4) Pedestrian walks shall not exceed a longitudinal slope of five (5) percent or a side slope of three (3) percent as measured over a ten-foot interval. b. Traffic Circulation Lanes. (1) Internal circulation lanes shall be no closer to the right-of-way than the minimum required stacking distance at the site driveway exit/entry as required by the City Traffic Engineer. (2) Site cross-access lanes shall be provided. Cross access lanes should be a minimum of twenty-four (24) feet wide. (3) Traffic lanes shall be clearly separated from parking and pedestrian areas through the use of landscaped islands, barrier curbs, or lane striping. (4) Vision clearance as specified in Section 2.06 of the Zoning Ordinance shall be utilized within parking areas as deemed necessary by the Administrator. (5) Truck traffic should be routed directly to service area without passing through parking or pedestrian areas. (6) Service truck parking should only be allowed within designated service areas. (7) Unless otherwise exempt by the Chief of Kenosha Fire Department, all circulation lanes adjoining the perimeter of buildings shall be designated as fire lanes. 17. Protection of Natural Features. a. Preservation. All new development shall preserve, enhance, or protect existing natural features. The Site Plan or accompanying documents shall evidence the means by which the development addresses the following: (1) Minimize disruption of existing natural features, and wherever possible, incorporating them into the overall design. (2) Prior to development, protecting all natural elements from damage due to construction activities. (3) Comply with Chapter XXXIII of the Code of General Ordinances, entitled "Erosion Control." (4) Comply with Section 34.10 of the Code of General Ordinances, entitled "Tree Protection." b. Open Space. The following specific areas shall be preserved as undeveloped open space: (1) Wetlands as described in Section 404 Federal Water Pollution Control Act Amendments of 1972 and delineated on the Wisconsin Department of Natural Resources Wetland Inventory Map, verified by on-site inspection by a qualified wetlands consultant. (2) Lands in a designated floodway or floodplain. Lands within a floodplain may be used for parking and recreational uses provided all required permits are obtained. (3) Steep slopes in excess of twenty (20) percent as measured over a ten-foot interval, unless appropriate engineering measures are taken. (4) Habitats of endangered wildlife or vegetation as identified by the Federal and/or Wisconsin Department of Natural Resources. 18. Multifamily Development Entranceways, Landscaped Islands and Parking Lots. Entranceways, landscaped islands and parking lots that abut a public street shall be curbed in multifamily developments between the first building and right-of-way line. D. Utility Plans. Utility Plans shall show and include: 1. Location and dimensions, in length and diameter where applicable, of all aboveground and underground conduits and utility lines: storm and sanitary sewers, water mains, electrical, natural gas, and communication (cable television, telephone, etc.) lines. 2. Location of all utility connections and metering facilities, including fire hydrants, Fire Department connections, existing wells, pumping stations and lift stations. 3. Road and paving cross-sections and details. 4. Location and footprint of any and all buildings and structures, in outline. 5. Locations and names of existing and proposed streets and intersections, and the location of parking lots, sidewalks, and bike paths, and other elements of vehicular and pedestrian circulation. 6. Plumbing plans showing in detail, the size and location of all water meters. 7. Storm sewer, sanitary sewer, and water utility systems, as outlined in the Utility Plan, shall meet the requirements of Chapter V and Chapter XXXII of the Code of General Ordinances. These provisions may require the designation of easements providing access for public utility purposes. 8. Electric, gas and telephone utility systems, as designated on the Utility Plan, shall meet the requirements of the respective utility company's rules and regulations. 9. Cable television systems, as designated on the Utility Plan, shall meet the requirements of Chapter XXVI, "Cable TV," of the Code of General Ordinances. 10. Utility systems shall be placed in accordance with City Ordinances and utility companies' rules and regulations. The Review Authority may require the underground installation of lines and distribution points, the elimination of poles and overhead lines, or the simultaneous organization and installation of utility systems. 11. Exterior lighting is intended to promote a safe and attractive character throughout Kenosha without creating a nuisance to adjacent properties. All exterior lighting shall comply with the following standards: a. Light fixtures shall be selected with care to ensure that they are appropriately scaled in relation to their setting and to ensure that they are of a style that is compatible with the character of their immediate environment. b. Luminaries shall be aimed, shielded, or relocated so as to minimize glare. c. The maximum allowable light spillover to an adjacent residential property shall be 0.5 foot candles measured at the property line, four (4) feet above grade; for all other types of land uses, the maximum allowable light spillover shall be 0.75 average foot candles, measured in the same manner. d. Lighting levels shall be measured in foot candles with a direct-reading, portable light meter. The meter sensor shall be mounted not more than four (4) feet above the ground line in a horizontal position. Readings shall be taken only after the cell has been exposed long enough to provide a constant reading. Measurements shall be made after dark with the light sources in question on, then with the same sources off. The difference between the two (2) readings shall be compared to the maximum permitted illumination. e. All lighting wires/cables shall be placed underground. f. Accent lighting should be used to highlight architectural and landscape design elements when appropriate. g. At the time any exterior lighting is installed or substantially modified, an exterior lighting plan shall be submitted to the Department of City Development and Traffic Engineer in order to determine whether the requirements of this Section have been met. h. Illumination of uses shall meet the minimum standards of Illuminating Engineering Society of North America (IES). i. Pedestrian walkways and parking areas shall be illuminated to a sufficient level so as to provide for security. E. Drainage Plan. Drainage Plan shall show and include: 1. Existing topography by contours related to USGS survey datum or other datum approved by the City Engineer. The contour interval shall be not greater than two (2) feet (a one-foot interval is recommended) and shall extend at least twenty (20) feet beyond the site. The City Engineer may require site elevations beyond twenty (20) feet of the site. Spot elevations of existing buildings, structures, high points, and wet areas or flood elevations shall be shown. 2. Floodplain, shoreland, environmental corridors, and wetland boundaries, if applicable. 3. Soil characteristics. 4. The location, capacity, and dimensions of on-site storm water drainage facilities, including manholes, pipes, curbs, gutters, curb inlets, curb cuts, and drainage grates and design calculators shall be provided. 5. Location, extent, and typical cross sections and slope ratios of all storm water retention and detention areas and drainageways. Location and elevations at top and bottom of proposed retaining walls. 6. The location and footprint of any and all buildings and structures. 7. The locations and names of existing and proposed streets and intersections, and the location of parking lots, sidewalks, bike paths, and other elements of vehicular and pedestrian circulation. 8. All development shall comply with the City's Land Division and Zoning Ordinance requirements for storm water retention and detention. Storm water retention and detention basins, including underground retention and detention basins, shall be constructed and operational prior to the issuance of a Footings and Foundation Permit. Underground storm water retention and detention basis shall only be allowed upon approval and recording of a Storm Water Maintenance Agreement. 9. Erosion control measures shall be exercised during construction to prevent unnecessary soil erosion from steep slopes, drainageways and topsoil stock piles as required by Chapter XXXIII of the Code of General Ordinances, "Construction Site Maintenance Erosion Control." Erosion control measures shall be identified on the site plan or in supporting documents. 10. A topographic analysis by the review authority shall consider: contours, elevations, and slopes; spot elevations of existing buildings and structures; spot elevations of rock outcroppings, high points, water courses, depressions, ponds, and marsh areas, with any previous flood elevations; floodplain boundaries, if applicable; and test pits or borings if required to determine subsoil conditions. 11. The Review Authority shall analyze the Drainage Plan to assure that the following conditions are met: a. Surface water runoff on the site shall be absorbed or retained on the site so that the rate of flow of surface water leaving the site would not be greater than if the site had remained undeveloped. b. Surface water from the site shall be discharged to a City storm sewer or ditch, where available and of sufficient capacity to handle the flow. c. Surface water flow may be directed onto adjoining private property only under the following circumstances: (1) The surface water follows a predevelopment drainage course. (2) The property owner of the site being developed executes an Indemnity and Hold Harmless Agreement with the City, drafted by the City Attorney. (3) Private drainage tiles may be connected to those on adjacent property only with the written permission of said property owner. d. Nonresidential uses and all parking areas shall not discharge surface water onto any property zoned residential unless such drainage is approved by the City Engineer. e. All floodland developments shall be elevated or floodproofed to an elevation at least two (2) feet above the elevation of the one hundred-year recurrence interval flood. f. Floodland developments shall not increase flood stages and flood discharges beyond the limits set forth in Sections 3.20 and 3.21 of this Ordinance. 12. The Review Authority may require site grading: a. To create drainage swales. b. To create berms as noise, wind, or visual barriers. c. To correct undesirable landforms. d. To raise the ground level above unfavorable subgrade conditions such as groundwater. e. To create, emphasize or control circulation routes such as paths or roads. f. To relate the site to the surrounding area. g. To prevent erosion and sedimentation. h. To provide storm water retention or detention basins for development of five (5) acres or more when such basins or other retention means are required to retain and limit any surface water runoff to its original rate of flow and point of discharge prior to development. F. Landscape Plans. Landscape Plans shall show and indicate: 1. The location and footprint of any and all buildings and structures. 2. Dimensions of development site, indicated along the property line. 3. Existing and proposed streets, drives, sidewalks, alleys and intersections, pedestrian and vehicular access points, bicycle paths, bridges, and other pedestrian and vehicular circulation elements, labeled with street names and dimensioned. Surface materials shall also be identified. 4. Location and dimensions of parking lots, parking spaces, and parking lot accessways. 5. Location and dimensions of all existing or planned easements, lands subject to covenant, lands to be dedicated or devoted to public use, and rights-of-way. 6. The location and dimensions of snow removal and storage areas. 7. The location and dimensions of outdoor lighting fixtures, freestanding signs, permanent or temporary walls and fences, waste and trash disposal facilities, surface utility structures, and other freestanding structural features. 8. The location and dimensions of playgrounds, tot lots, and other recreational facilities. 9. Details of all permanent fences and walls to be constructed on the site, including dimensioned elevations and materials schedules. 10. Existing and proposed contours and grades, including the location, slope ratios (horizontal to vertical), of all proposed berming, at a one-foot contour interval. Location, extent, and general elevations and slope ratios of all surface water retention and detention areas and drainageways. Elevations at top and bottom of all proposed retaining and screening walls and fences. Existing lines should be shown as dotted lines. 11. All plants shall only be labeled or identified on the plan as either a coniferous or deciduous plant. The location, quantity, installation size, and distance between plants shall be identified. 12. Specification of the type and boundaries of all proposed ground cover, including both scientific and common names of all proposed plant materials. 13. The location of paving materials and non-living ground cover which is identified by description and brand names. 14. Location, species, and size of all existing trees that are three (3) inches or larger in diameter, measured fifty-four (54) inches above natural grade. Any trees to be removed should be clearly identified. Trees measuring three (3) inches or greater which will be used to meet landscape requirements shall also be indicated. If required for reasons of clarity, this information may be depicted as a supplemental illustration. 15. Tree line of wooded areas. 16. Orchards or other agricultural groves by common or scientific name. 17. A Landscape Improvement Table with the following information: a. Square footage of parking lot area. b. Square footage, and percentage of interior parking lot landscape area expressed as a ratio to total parking lot area. c. Number of trees provided for parking lot interior. d. Plant quantities provided for buffer strips and medians. e. Square footage of interior open spaces. f. Number of trees on interior open spaces. 18. Proposed location of all utilities on the site; i.e., gas, water, sewer, cable, irrigation, drainage, etc. 19. Compliance with Section 4.06 of the Zoning Ordinance, entitled "Landscape Standards" and Section 34.10 of the Code of General Ordinances, entitled "Tree Protection." 20. Plan should identify how plantings and buffer area will be maintained including location of any irrigation systems. 21. Recommended Trees, Shrubs and Ground Cover. Species and/or varieties of trees, shrubs and ground cover shall be those recommended by the City Forester or the most recent version of "A Guide To Selecting Landscape Plants For Wisconsin," by E.R. Hasselkus. The following criteria shall also govern selection: a. Size in relation to proximity to buildings, utilities, entrances, pedestrian walkways, roads and other improvements. b. Species in relation to plant hardiness (Zones 5 through 2), disease or insect resistance, and low maintenance.

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.