§ 3.32 — TRD-2 Traditional Multiple Family Residential District
Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Zoning Ordinance § 3.32
Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/b351ed74-5eef-4138-a254-e49191e13fc3
3.32. - TRD-2 Traditional Multiple Family Residential District.
The primary purpose and characteristics of the TRD-2 Traditional Multiple Family Residential District is to provide for residential development at minimum density of six (6) dwelling units per acre, but not to exceed twelve (12) dwelling units per acre, unless otherwise specified in an adopted land use or master plan. This District is further intended to provide for a traditional residential community encompassing no less than five (5) acres of land or at least one (1) block, which accommodates a mixture of multiple family housing types, such as apartment buildings, townhouses, and condominiums that are designed to establish and/or reinforce the street with building entrances primarily addressing the street and creating an environment that promotes pedestrian activity and interest on the street. The principal buildings are typically situated on narrower lots with shorter setbacks to the front and side yards, which still allow for porches, fences and small lawns. The parking is generally accessed from a rear alley and located behind the front façade of the principal building. A. Permitted Uses. Community Living Arrangements with a capacity for fifteen (15) or fewer persons which are in conformance with Wis. Stats. § 62.23(7)(i), including Assisted Living Facilities. B. Permitted Accessory Uses. 1. Boathouses; private, noncommercial. 2. Garages and carports; private, noncommercial. 3. Greenhouses; private, noncommercial. 4. Home Occupations, as permitted in Section 3.03 of this Ordinance. 5. Off-street parking spaces and parking facilities, in conformance with Section 6.01 of this Ordinance. 6. Outdoor signs, in conformance with Chapter XV of the Code of General Ordinances, and in conformance with any more restrictive requirements of an approved Developers' Agreement. 7. Swimming pools; private, noncommercial and in conformance with Chapter IX of the Code of General Ordinances. 8. Tennis and game courts; private, noncommercial. C. Conditional Uses. 1. Multifamily residences containing three (3) or more units per lot in conformance with the Development Standards of this Ordinance, at a minimum density of six (6) dwelling units per acre, to a maximum density of twelve (12) dwelling units per acre, unless otherwise specified in an adopted Land Use or Master Plan. 2. Community Living Arrangements with a capacity for greater than fifteen (15) persons which are in conformance with Wis. Stats. § 62.23(7)(i), including Assistant Living Facilities. 3. Historic monuments. 4. Private parks and playgrounds, including buildings and grounds, and properly licensed concessions primarily serving residents and guests. 5. Utility substations. 6. Storm water detention and retention basins. D. Lot Area and Width. There shall be no minimum lot area and width requirements, except that all other provisions of the Zoning Ordinance and Code of General Ordinances shall be met. E. Building Height. Principal buildings shall not exceed forty-five (45) feet in height. Accessory buildings shall not exceed thirty-five (35) feet in height. F. Front Yards. Interior lots shall have one (1) front yard with street frontage and corner lots shall have two (2) front yards with street frontages. 1. Setback and Frontage Requirements. The front façades of all buildings which face a public or private street shall adhere to the following requirements: a. There shall be a minimum front yard setback of fifteen (15) feet and a maximum front yard setback of twenty-five (25) feet, measured from the front lot line, which is the right-of-way line of any public street or any required easement or accessway for a private street, or from the setback line of any major street, whichever is greater. b. A minimum of sixty (60) percent of the principal building width, measured along the ground level of the front façade, shall be located within the front yard setbacks. Accessory buildings, including approved integrated architectural walls, garden walls, retaining walls and fences, shall count toward this requirement, provided that they are located at or behind the ground level of the front façade that is located the closest to the front lot line. c. An exception to maximum front yard setback requirement in Section F.1.b. may be granted for the street-facing façade that does not contain a primary entrance when the Department of City Development has determined that a lot is considered an irregular-shaped corner lot, provided that this façade still complies with the maximum front yard setback requirement to the extent possible. 2. Projection Requirements. The front façades of each principal building which face a public or private street shall adhere to the following requirements. a. Any permitted architectural elements and/or similar features, such as awnings, bay windows, balconies, stairs, roof eaves and trellises, including unenclosed and covered porches, stoops, patios, porticos and pergolas, as well as approved integrated architectural walls, garden walls, retaining walls, and fences, are allowed no closer than seven (7) feet from the front lot line. The roof over an unenclosed and covered porch, stoop, patio, portico and pergola shall be at least thirty (30) percent solid. b. A minimum of twenty-five (25) percent of the principal building width containing a primary entrance, measured along the ground level of the front façade, excluding the garage wall where the garage door openings face a public or private street, shall include one (1) or more of the permitted items identified in Section F.2.a. that extend at least two (2) feet beyond the living portion(s) of the front façade. G. Interior and Rear Yards. Interior lots shall have two (2) interior yards. Corner lots shall have one (1) interior yard. 1. Interior and Rear Yard Setbacks for Principal Buildings. There shall be a minimum interior and rear yard of ten (10) feet from the lot line to the principal building, and a minimum of twenty (20) feet shall be maintained between principal buildings. 2. Interior and Rear Yard Setbacks for Accessory Buildings. There shall be a minimum interior and rear yard of four (4) feet from the lot line to the accessory building, and a minimum of four (4) feet shall be maintained between accessory buildings. 3. Distances Between Principal and Accessory Buildings. Accessory buildings shall not be constructed closer than five (5) feet to any principal buildings. H. Front-Facing Garages. The width of front-facing garages shall not comprise more than fifty (50) percent of the width of the principal building as measured along the ground level of the front façade containing the primary entrance. In addition, one (1) of the following requirements shall be met: 1. Front-facing garages shall not extend closer to the front lot line than the liveable space of the principal building; or 2. Front-facing garages shall not extend closer to the front lot line than an unenclosed and covered porch and/or pergola provided that the width of the unenclosed and covered porch and/or pergola is at least fifty (50) percent of the width of the front-facing garage wall as measured along the ground level of the front façade containing the primary entrance. The unenclosed and covered porch and/or pergola shall be a minimum of twenty-five (25) square feet and incorporate the use of decorative posts, columns, piers, railings, balustrades, brackets, trellises, or other similar design elements to minimize the appearance of the front-facing garage to the extent possible. I. Off-Street Parking Requirements. Ground level parking shall be located at or behind the front façade of the principal building. Any parking which is located at the side of the principal building shall be screened through the use of approved integrated architectural wall and/or landscape treatments. 1. The driveway apron shall be a minimum of twenty (20) feet in length, measured from the front lot line, and such driveway apron shall not exceed the width of the driveway approach at the front lot line. 2. There shall be a minimum of one (1) parking space for dwellings units with less than two (2) bedrooms, and a minimum of two (2) parking spaces for dwelling units with two (2) or more bedrooms. J. Building Composition and Character. 1. Roof Element/Composition. Roofs shall be pitched, hipped, or gabled, and overhanging eaves are encouraged. Flat roofs with articulated parapets and cornices are allowed. The total height of the roof that faces a public or private street from the lowest portion of the roof to the ridge line shall be no greater than the height of the façade of the building, measured vertically from the ground level of the façade to the lowest portion of the roof. 2. Building Façade/Composition. All buildings shall have a well defined front façade with the primary entrance facing a public or private street. The buildings shall be aligned so the dominant lines of their façades parallel the line of the street and create a sense of enclosure. Departures may be permitted to terminate important vistas or to act as focal points for public or private spaces. a. A minimum of one (1) primary entrance shall face a public or private street for all principal buildings, and only one (1) primary entrance shall be required where the front façade of the principal building faces more than one (1) street, and this entrance shall first face the public street where available. All principal buildings with front façades which exceed three hundred (300) feet in width shall have more than one (1) primary entrance facing the public or private street. b. Windows and/or entrances shall comprise at least ten (10) percent of the total wall area of each façade of the principal building, provided that at least five (5) percent of the total wall area for each floor of the principal building includes windows and/or entrances. Windows in garage walls, but not in garage doors, shall count toward this requirement. Any projections and recesses involving the principal building, including garage walls and garage door openings that face a public or private street shall be included in the total area of each façade. The total wall area shall be calculated as follows: (1) The vertical distance between the floor and ceiling lines for each floor, excluding any overhangs and roof projections, shall be used to determine the overall total wall area of each façade. Any projections and recesses involving a change in a wall plane of at least six (6) feet in depth shall be calculated separately in order to satisfy the window and/or entrance requirement for each floor of the principal building in Section J.2.b. (2) Windows and/or entrances shall only be required for all wall areas of each floor with a minimum of eight (8) feet in height and a minimum of six (6) feet in width, whether or not the wall area includes living portions of the principal building. (3) Where there is no living portion of the principal building, a decorative wall vent and/or louver of at least five (5) percent of the total wall area may be substituted for a window and/or entrance, and such wall vent and/or louver shall be calculated separately from the total wall area requirement for windows and/or entrances in Section J.2.b. 3. Garage Façade/Composition. The sides of the garage wall, whether attached to, or detached from, the principal building where the garage door openings do not face a public or private street, shall be designed to be integral with the design features of the principal building. K. Building Materials. 1. Permitted Building Materials. The exterior of all multifamily buildings shall consist of architectural masonry and/or glass. In addition, the following requirements shall be met: a. Integrated architectural walls, garden walls, retaining walls, fences and gates shall be of masonry, wood or decorative metal. Chainlink or similar material is prohibited. b. Hedges and evergreen shrubs used in combination with masonry and/or decorative metal fencing may replace mandated integrated architectural walls, garden walls, retaining walls, and fences. 2. Prohibited Building Materials. Exterior building materials shall not include smooth faced concrete block, tiltup panels, or prefabricated steel panels. L. Mechanical Equipment/Outdoor Storage. 1. Mechanical Equipment. All vents, conduits, utility meters and other mechanical equipment or similar facilities which are attached to or detached from the front façade of the principal building, including all rooftop equipment, shall either be compatible with or integrated into the building and roof design to the extent possible and/or screened from view of a public or private street through the use of approved integrated architectural wall and/or landscape treatments. 2. Outdoor Storage, Loading, and Parking. Service entries, trash collection and/or compaction, along with other service functions, shall be incorporated into the overall design of the building and the landscape so that the architectural design is consistent. The above areas shall be located and screened so the visual and acoustical impact of these functions are fully contained and out of view from adjacent properties and public or private streets to the extent possible. M. Special Exceptions. 1. Procedure. Special exception requests shall be made in writing to the Department of City Development. Any special exception granted shall be considered unique to the project and will not set any precedent for future decisions. The City Plan Commission is designated the authority for granting a special exception from the requirements of the District. The special exception shall only be granted to the minimum extent practical in order to provide relief to the requirements of the District. 2. Criteria. The City Plan Commission may consider granting a special exception from the requirements of the District, provided that all of the following criteria are met: a. Unique Circumstances. There are exceptional, extraordinary or unusual circumstances or conditions where a literal enforcement of the requirements of the District would result in severe hardship. Such hardships shall not generally apply to other properties or be of such a recurrent nature as to suggest that the requirements of the District should be changed. b. Absence of Detriment. The special exception will not create a substantial detriment to adjacent property. In addition, the special exception shall not result in development that would be impractical or detract from the appearance of the District and shall not adversely affect emergency vehicle access and deprive adjoining residential properties of light and air. c. Conformity. (1) The special exception will not conflict in any way with the Wisconsin State Statutes or the City Comprehensive Plan. (2) The special exception shall be in harmony with the overall purpose of the land use and development standards and guidelines for the District. (3) The proposed design substantially meets the intent of the District to line streets with active living spaces, create pedestrian-oriented streetscapes, and provide variety and visual interest in the exterior design of the buildings.
Ask a question about Kenosha law
Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.
