For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 103-236 — Additional regulations

Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-236

Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/22f7f665-f642-4782-a04d-c6b689d25242

Sec. 103-236. - Additional regulations.

(a) Water supply. All water service installations shall comply with Water Utility rates, rules, regulations, policies and ordinances governing the introduction, supply, installation and consumption of water. (b) Sewers. (1) Connections with sewer mains. The City Engineer shall inform plumbers of the position and junctions of sewer mains as far as known, but the City shall not be responsible for the correctness of such information. When no junctions are found in a public sewer within three feet from the flow side of the measurement given by the City Engineer, a length of the sewer main shall be removed and a "Y" connection inserted in its place to serve as the connection. If the building sewer is five inches in size or less, and permission is given by the Fire Department - Division of Fire Prevention and Building Safety, a new tap or connection may be made by tapping the main, by carefully cutting a round opening in the main so a hub of the private sewer will rest on the sewer main, such hub to have a short piece of pipe extended into the tap to be flush with the inside wall of the main. Where the hub is placed on top of the sewer main, a cast iron pipe rest shall be placed on the main before the hub is placed on the main. Such connection shall be secured by ample cementing or grouting. The cement used shall be composed of one part cement to two parts of clean sharp sand. All such work shall be done only in the presence of the City Plumbing Inspector. All such junctions shall be made at the expense of the plumber. (2) Sewers to be kept free from sand. No plumber shall allow any earth, sand or other solid material to pass, flow or run into any sewer while cutting into or making any connection therewith, or while doing any work in laying, altering or repairing any drain connected with the main sewer. All sewer pipes shall be laid with bell end up grade and laid on a firm bed of earth which shall be thoroughly tamped. (c) Boilers. (1) All potable water lines to water or steam boilers shall have a control valve and cross connection control installed before the water supply enters the boiler. All water and steam boilers shall have a temperature and pressure relief valve installed on the boiler. (2) Boiler compounds, solutions or chemicals that are in contact with or injected into the boiler may be of a type that is nonpoisonous and nontoxic. The user shall supply the Fire Department - Division of Fire Prevention and Building Safety with a certified statement by a nationally recognized testing laboratory that such compound, solution or chemical is nonpoisonous and nontoxic by virtue of tests conducted before the boiler is put into operation. Nonpoisonous and nontoxic additives shall only be used after installation of an approved backflow prevention device between the boiler and potable water. Poisonous or toxic compounds, solutions or chemicals shall only be used after installation of an approved reduced pressure device between the boiler and potable water. (3) Steam boilers shall have safety feeders and low water cutoffs installed. Steam boiler feeder and low water cutoffs shall have separate controls and not combined. (d) Private wells. Permitting of private wells shall be as required in section 46-41. All private water supplies shall be uncontaminated and the source shall, in construction or abandonment, comply with the specifications of Wis. Admin. Code ch. NR 812, which is hereby adopted by reference. (e) Cross connections. The public water system shall be protected from all cross connections as required in section 46-40. No potable water system shall be connected to any part of a drainage or impure water system unless adequately protected against back-siphonage. When a new water lateral is connected to the public water system the existing private well shall only be allowed to be used for outdoor hydrants, irrigation systems, HVAC systems or other uses as approved by the Water Utility. Private wells shall be isolated from all municipal water systems. (f) Discharge of sewage or wastes. No person shall discharge sewage, industrial wastes, or effluent, except clear water, into any lake, pond, river, or stream or into any storm sewer connected with or discharging into said waters. No person shall permit any sanitary drain or waste to discharge into any open storm sewer or gutter, upon the ground, in any public street or alley, or upon any sidewalk. (g) Private Sewage Systems. The Board of Public Works shall approve any private sewage system within the corporate limits of the City of La Crosse. Septic or other sewage treatment tanks and seepage pits, or drainage fields shall be constructed where no public sewerage system is available or likely to become available within a reasonable time, conforming to the Wisconsin State Plumbing Code as to location, materials, capacity, design, disposal of sludge and effluent, and ventilation. Connection with the public sewer shall be made within six months after the public sewer is available. All abandoned septic tanks, drywells, seepage pits, cisterns, and wells shall be immediately removed or filled, pursuant to Wis. Admin. Code § SPS 383.33. (h) Tracer wires. A tracer wire shall be installed with all non-metallic laterals, from the main, curb stop or property line to building, and it shall be sized to a minimum of #12 AWG copper covered conductor. The wire covering color code for piping type shall be blue for water, green for sanitary, and brown for storm laterals. (i) Miscellaneous requirements. (1) Plumbing installations shall comply with sections 103-328 and 103-337. (2) No fire or flames shall be used to thaw frozen pipes. (3) All pipe holes are to be plugged for fire stopping, and those which are abandoned and empty and those which are larger than the pipe, either with the same material through which the opening is made or with noncombustible material. (4) Plumbing installations for accessory structures shall be restricted in accordance with section 115-390.

(Code 1980, § 19.10(A)—(I); Ord. No. 4851, § VI, 12-11-2014)

Ask a question about La Crosse law

Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.