Sec. 103-443. - Substandard buildings.

(a) General. Any dwelling, dwelling unit, or premises upon which the same is located, or portion thereof, in which there exists any condition that endangers the life, limb, health, property, safety or welfare of the public or the occupants thereof is hereby declared to be a substandard building. (b) Inadequate sanitation. Dwellings, dwelling units, or portions thereof, shall be deemed to be a substandard building when they are unsanitary. Inadequate sanitation shall include, without limitation, the following: (1) Lack of, or improper water closet, lavatory, bathtub or shower in a dwelling or dwelling unit. (2) Lack of, or improper, kitchen sink in a dwelling or dwelling unit. (3) Lack of hot and cold running water to plumbing fixtures in a dwelling or dwelling unit. (4) Lack of adequate heating facilities. (5) Lack of, or improper operation of, required ventilating equipment. (6) Lack of minimum amounts of natural light and ventilation required by this article. (7) Room and space dimensions less than required by this Code. (8) Lack of required electrical lighting. (9) Dampness of habitable rooms. (10) Infestation of insects, vermin or rodents. (11) General deterioration, dilapidation or improper maintenance. (12) Lack of connection to required sewage disposal system. (13) Lack of adequate garbage and rubbish storage and removal facilities. (c) Structural hazards. Dwellings and dwelling units, or portions thereof, shall be deemed to be a substandard building when they contain structural hazards. Structural hazards shall include, without limitation, the following: (1) Deteriorated or inadequate foundations. (2) Defective or deteriorated subflooring or finish flooring systems which were installed or have deteriorated such that they cannot support live and dead loads placed upon them. (3) Structural floor framing systems that sag, split or buckle due to defective, deteriorated or inadequate material and fail to transfer live and dead loads placed upon them safely to bearing points. (4) Structural framing members of bearing walls, partitions or other vertical supports that split, lean, list or buckle due to defective, deteriorated or inadequate material. (5) Structural framing members of roofs, ceilings or other horizontal framing members that sag, split or buckle due to defective, deteriorated or inadequate material and fail to transfer live and dead loads placed upon them safely to bearing points. (6) Fireplaces or chimneys that list bulge or settle due to defective material or deterioration. (7) Fireplaces or chimneys that are of insufficient design, condition, size or strength to transfer dead and live loads safely to bearing points. (d) Non-structural hazards. Dwellings, dwelling units, or portions thereof, shall be deemed to be a substandard building when they contain a non-structural hazard. Non-structural hazards shall include, without limitation, the following. (1) Hazardous electrical wiring. Electrical wiring that was installed in violation of article requirements in effect at the time of installation or electrical wiring not installed in accordance with generally accepted construction practices in areas where no codes were in effect or that has not been maintained in good condition or that is not being used in a safe manner. (2) Hazardous plumbing. Plumbing that was installed in violation of code requirements in effect at the time of installation or plumbing not installed in accordance with generally accepted construction practices in areas where no codes were in effect or that has not been maintained in good condition or that is not free of cross-connections or siphonage between fixtures. (3) Hazardous mechanical equipment. Mechanical equipment that was installed in violation of code requirements in effect at the time of installation or mechanical equipment not installed in accordance with generally accepted construction practices in areas where no codes were in effect or that has not been maintained in good and safe condition. (4) Faulty weather protection hazard. Faulty weather protection includes, without limitation, the following: a. Deteriorated, crumbling or loose plaster. b. Deteriorated or ineffective waterproofing of exterior walls, roof, foundations or floors, including broken windows or doors. c. Defective or lack of weather protection for exterior wall coverings, including lack of paint, or weathering due to lack of paint or other approved protective covering. d. Broken, rotted, split or buckled exterior wall coverings or roof coverings. (e) Other substandard buildings designations. (1) Fire hazard. Any building or portion thereof, device, apparatus, equipment, combustible waste, or vegetation that, in the opinion of the Chief Inspector or the Fire Chief, is in such a condition as to cause a fire or explosion or provide a ready fuel to augment the spread and intensity of fire or explosion arising from any cause shall be deemed a substandard building. (2) Unapproved or improper use of construction materials. The Chief Inspector may declare a building, or portion thereof, to be a substandard building due to improper application and installation of construction materials or the use and application of materials lacking a State of Wisconsin Building Material Approval. (3) Hazardous, unsanitary premises. The Chief Inspector may declare a building, the premises upon which the building is located, or portion thereof, to be a substandard building when it is found that an accumulation of weeds, vegetation, junk, dead organic matter, debris, garbage, offal, rat harborages, stagnant water, combustible materials, and similar materials or conditions on the premises constitute fire, health or safety hazards or a blight upon the neighborhood. (4) Inadequate exits. The Chief Inspector may declare a building, or portion thereof, to be a substandard building when an unsafe condition exists through an improper or inadequate provision or location of exits or exit width, or when any other conditions exist that the Chief Inspector deems as dangerous to human life. (5) Inadequate fire protection or firefighting equipment. Buildings, or portions thereof, shall be declared a substandard building when they are not provided with the fire-resistive construction smoke detectors or fire-extinguishing systems or equipment required by this article, except those buildings, or portions thereof, that conformed with all applicable laws at the time of their construction and whose fire-resistive integrity and fire-extinguishing systems or equipment have been adequately maintained and improved in relation to any increase in occupant load, alteration or addition, or any change in occupancy. (6) Illegal occupancy or use. All buildings, or portions thereof, occupied for living, sleeping, cooking or dining purposes that were not designed or intended to be used for such occupancies shall be declared to be a substandard building.

(Code 1980, § 8.07(F))

Ask a question about La Crosse law

Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.