§ 115-556 — Exterior lighting
Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 115-556
Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/c8e7c0b7-5947-4107-a7db-74c22f5a7afa
Sec. 115-556. - Exterior lighting.
(a) The intent of this section is to enhance daytime and night time appearances; to establish a safe environment, and to minimize light pollution, glare and light trespass onto adjacent properties. The use of solar, LED or low watt compact florescent lights that decorate the property and are located and directed where people need to see in the dark are encouraged. (b) All exterior lights shall be designed for commercial use. A lighting plan showing lighting levels on-site and at the property line as well as spec sheets with pictures must be submitted with the design standards checklist for each exterior light to be used. (c) Pedestrian lighting shall clearly indicate the path of travel, shall minimize dark spots along that path, and shall utilize coordinated light fixtures. (d) The maximum height of wall mounted parking lot light fixtures shall be 16 feet above the ground. Pole-mounted fixtures are acceptable but not required and will have a maximum height of 30 feet from the ground to the top of the fixture. Fixtures shall be of full-cut-off (FCO) design to minimize glare and spillover. (e) Ornamental lighting to light the building facade is permitted, provided that the light source is not visible from the property line and is designed to minimize glare and spillover. (f) No overhead light source (i.e., the lamp or reflector) shall be visible from the property line. Shields may be employed, if necessary, to meet this requirement. The maximum allowable luminance measured 25 feet beyond the property line shall be 0.05 horizontal footcandles (HFC). (g) Lighting levels for parking lots and pedestrian routes: (horizontal luminance measured in footcandles): (1) Average: 2.4 footcandles. (2) Minimum: 1.0 footcandles. (3) Uniformity ratio (bright spots to dark spots): 4:1. (4) Maximum average: 5.0 footcandles. (h) Each exterior entry to structures on the property shall have an exterior light. (i) For properties adjacent to residential uses, motion sensor flood or spot lights shall have shrouds, be limited to two bulbs pointed at least 30 degrees downward and not directly into windows or doors of neighboring building and the light sources shall not be visible from the street.
(Code 1980, § 15.47(T))
Ask a question about La Crosse law
Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.