27.04 - MINIMUM STANDARDS FOR BASIC EQUIPMENT, LIGHTING, VENTILATION, HEATING, AND ELECTRICAL SERVICE.
(1) The purpose of this subsection is to establish minimum standards for basic equipment, lighting, ventilation, and electrical services for all residential buildings and parts thereof and to obtain the public and private benefits accruing from the provision of such services. A suitable environment for safe and healthy living is encouraged by adequate water and sanitary facilities, proper storage and disposal of garbage and other refuse, safe means of egress, provision of light, air, heat, and electrical service. (2) No person shall occupy as owner or let to another for occupancy any space in a residential building for the purpose of living, sleeping, cooking or eating therein, which does not comply with the following requirements: (a) Every dwelling unit shall contain a kitchen sink, a flush water closet, a lavatory basin and a bathtub or shower, all in good working condition and properly connected to hot and cold water lines and to an approved water and sewer system. The flush water closet and bathtub or shower shall be contained within a separate room. Water pressure shall be available at all fixtures as specified in Wis. Admin. Code § SPS 382.40. (Am. by Ord. 9299, 10-29-87; Ord. 13,124, 8-28-02; ORD-12-00035, 3-28-12) (b) Every residential building shall have supplied water heating facilities which are properly installed, are maintained in safe and good working conditions, are properly connected with the hot water lines required hereunder and are capable of heating water to such a temperature as to permit an adequate amount of water to be drawn at any required kitchen sink, lavatory basin, bathtub or shower at a temperature of not less than one hundred twenty (120) degrees Fahrenheit. (c) The owner of every residential building shall be responsible for supplying such building with garbage and refuse storage facilities as required by the Madison General Ordinances. (Am. by Ord. 9725, 3-2-89) (d) Every dwelling unit and lodging room shall have direct access to at least two (2) accessible unobstructed means of egress leading to a safe and open public street, alley, or court connected to a street, except as provided in Sec. 27.06(4), MGO. Exterior stairways or exit platforms, or a combination thereof, will be permitted as second exits provided the platform or stairways terminate at a point not more than fifteen (15) feet above the grade directly below the lowest platform. All stairs shall terminate at grade or a platform. Platforms shall have a minimum area of 14 square feet with a minimum dimension of three (3) feet. All stairways and platforms shall be protected with handrails and guardrails as specified in Wis. Admin. Code § SPS 321.04(2) or ch. SPS 362. Existing variances to the height limitations specified above may be approved by the Building Inspection Division of the Department of Planning and Community and Economic Development provided the platforms or stairs are maintained in a sound structural condition. (Am. by Ord. 9326, 11-13-87; Ord. 13,124, 8-28-02; ORD-08-00109, 10-7-08; ORD-12-00035, 3-28-12) (e) Each lodging house shall provide at least one (1) flush water closet, lavatory basin, and bathtub or shower, properly connected to an approved water and sewer system and in good working condition, for each seven (7) persons or fraction thereof residing therein including members of the operator's family wherever they share the use of said facilities, except that the required number of bathtubs or showers may be reduced by the Board of Building Code, Fire Code, Conveyance Code and Licensing Appeals for lodging houses utilizing communal bathrooms containing multiple bathtubs or showers. All such facilities shall be located on the floor occupied by persons sharing such facilities or the floor directly above or below and shall be accessible from a common hall or passageway. Every lavatory basin and bathtub or shower shall be supplied with hot water at all times. (Am. by Ord. 11,960, 11-4-97; ORD-09-00019, 3-14-09) (f) Every living, sleeping, kitchen or bath room shall have available natural light and ventilation complying with Wis. Admin. Code § SPS 321.05 or ch. SPS 362, as dictated by the occupancy of the building. Existing light and ventilation conditions which do not comply with Wisconsin Administrative Codes referenced in this subsection may remain in use with the approval of the Director of the Building Inspection Division. Exhaust ventilation shall be installed in all toilet rooms except those having only one (1) fixture (water closet or one urinal) and the window area is greater than four (4) square feet and more than two (2) square feet is openable directly to the exterior of the building. The volume of air exhausted shall not be less than two (2) cubic feet per minute per square foot of floor area. All doors required for ventilation and all windows shall be protected with insect screen equivalent to not less than sixteen (16) wire mesh installed to prevent the entrance of flies, mosquitoes and other insects, annually during May before June 1 and maintained until storm windows are installed in autumn. All exterior doors and windows shall have storm windows or storm doors installed or maintained to prevent excessive drafts and heat loss no earlier than October 15, but no later than November 15 annually. (g) Electrical. Every dwelling unit and all public and common areas in multiple dwellings shall be supplied with electrical service, outlets, and fixtures which shall be properly installed, shall be maintained in good and safe working condition, and shall be connected to a source of electric power in a manner prescribed by the Wisconsin Electric Code. The minimum capacity of such electrical services and the minimum number of outlets and fixtures shall be as listed below. (For the purposes of this section "electrical service" shall mean: "The conductors and equipment for delivering electrical energy from the supply system to the wiring system of the premises or the unit served.") The electrical service shall be of sufficient size to handle the load connected to it. The branch circuits shall be protected by S-type or equivalent safety type, tamper-proof fuses, not to exceed the ampacity of the smallest wire size in the circuit. 1. Every dwelling unit or room shall have electric service capable of providing at least three (3) watts per square foot of total floor area (air conditioners, ranges, space heaters and motor driven equipment ⅛ hp. or over excluded). 2. Every lavatory, bathroom, kitchen or kitchenette, dining room, laundry room, furnace room shall contain at least one (1) approved ceiling or wall type electric light fixture equipped with sufficient lamps or tubes to provide no less than five (5) foot candles at floor level at center of room. Where more than one fixture is used or required, they shall be equally spaced as far as practicable. (A switched outlet may be substituted for ceiling or wall fixture in dining room.) 3. Convenience outlet receptacles shall be provided as follows: (measurements are at room perimeter and include doors and door-alcoves) Living Room - 1 per 75 sq. ft. or major fraction (minimum of 2) Dining Room - 1 per 75 sq. ft. or major fraction (minimum of 2) Kitchen - 1 per 8 ft. or fraction of countertop and preparation area measured at rear (preparation area includes countertops, sinks, range tops, and all other similar areas at counter height). Island type work areas require one for each 8 ft. or less of length. Separate outlets shall be provided for refrigerators. Dining Areas in Kitchen - 1 per 75 sq. ft. or major fraction Bedroom - 1 per 75 sq. ft. or major fraction (minimum of 2) Laundry - 1 (when laundry equipment is present) Bathrooms and Lavatories - 1 (may be part of wall fixture if 72.0 inches or less from floor) Other Habitable Rooms - minimum of 2 Fixed appliances exceeding ⅛ hp. or 300 watts rating shall not be connected to general purpose branch circuits. Convenience outlets are to be located to prevent use of extension cords (NEC 400-8). All cords and temporary wiring not in compliance with NEC Article 400-A, and all exposed abandoned wiring shall be removed. 4. Switches or equivalent devices for turning on any light required in a room or passageway shall be located so as to conveniently control the area to be lighted. (Am. by Ord. 10,192, 1-31-91) 5. Public halls and stairways in duplex or multiple dwellings shall be adequately lighted by natural or electric light at all times, so as to provide in all parts thereof at least two and one-half (2½) footcandles of light at the tread or floor level. Halls and stairways in structures containing not more than three (3) dwelling units may be supplied with conveniently located switches, controlling the lighting system, which may be turned on when needed. Other occupancies require full-time or automatic time-switched lighting. In all residential buildings where common main entrance doors open directly to the outside, a minimum of two and one-half (2.5) footcandles of illumination at the locks and latches are required. In single, duplex, or multiple dwellings when dwelling unit or lodging room doors open to the outside a minimum of two and one-half (2½) footcandles of illumination at the locks are required. Parking lots for more than three (3) cars shall be lighted to provide at least .25 footcandle on any surface in the lot with an average illumination level of at least .75 footcandle, except that the outer four (4) feet of the periphery of the parking lot will not be subject to the .25 footcandle minimum. Outdoor light fixtures shall be designed and installed to eliminate spill light and glare into adjacent properties. (Am. by Ord. 12,349, 3-30-99) 6. When the service in an existing residential building is changed the minimum replacement electrical service shall be: 100 amp for first two (2) dwelling units in a building 50 amp for each additional unit. Where electric heat and air conditioner over 20 amps are added or in place, additional capacity to cover this demand is required. 7. Electric work shall be done according to applicable sections of Chapter 19 (Electrical Code) of the Madison General Ordinances. (h) Heating. All habitable rooms, kitchens and bathrooms shall be provided with a permanently connected heating system complying with Chapter 30 (Heating, Ventilating and Air Conditioning Code) of the Madison General Ordinances. Refer to Sec. 30.03(1) and Sec. 30.04(4)(d). The heating system shall be maintained in a safe and efficient condition by a qualified person and a record kept at the premises showing the date of service and by whom. A minimum temperature of sixty-seven degrees Fahrenheit (67°) shall be maintained in all habitable rooms, kitchens and bathrooms. The occupant of a room or an apartment may maintain a lesser temperature than is specified above as long as it does not affect the temperature in other habitable areas of the building. (i) Illumination shall be provided at all intersections of passageways, at all exits and at the head, foot, and landings of every stairway in all buildings accommodating transients, three (3) or more apartments, and lodging houses. The illumination shall be provided during a period one (1) hour before sunset to one (1) hour after sunrise. Every residential building that will accommodate transients, four (4) or more families, thirty (30) persons or contains more than six (6) lodging rooms shall have signs at the emergency exit doors or other places as may be necessary to direct the occupant to the exit doorways. The signs shall be red illuminated translucent exit signs bearing the word EXIT or OUT in plain letters not less than 5 inches in height. (j) The owner or operator of every residential building shall not provide, use, or permit to be used and the occupant shall not provide, use, or permit to be used in any room other than a kitchen, any equipment designed or intended to be used for cooking or preparation of meals. (Am. by Ord. 5139, 9-3-75) (k) Every owner of a rental dwelling shall keep on record with the Building Inspection Division of the Department of Planning and Community and Economic Development contact information of one (1) or more persons who, by virtue of their ownership, employment, or delegation, can exercise control and care over the property. 1. The contact information shall include the actual name of the owner per deed to the property, one or more contact names of the individuals designated to be contacts, one phone number for each contact listed, an email address (if available) for each of the contacts, and contact information for a management company for the property, if one is being utilized. 2. These names and contact information shall be updated with the Department at any time there is a change in the contact information. This information shall be provided on a form approved by the Department. 3. The City of Madison, through its Police Department, Fire Department, and Building Inspection Division, shall by use of the data collected, communicate promptly with a property owner and make the property owner aware of any police calls to the property, fire or ambulance calls to the property, and/or building inspection orders. 4. A fee in the amount of ten dollars ($10) per parcel shall be paid to the City Treasurer at the time the updated information is provided by printed form. No fee shall be charged if the information is submitted online. (Am. by ORD-14-00123, 7-11-14) 5. The owner may either submit this information online or request a printed form by email. 6. Exceptions. This requirement does not apply to all properties that are owned and operated by local, state, or federal government agencies, or a subdivision or agency of government.
(Sec. 27.04(2)(f) Am. by Ord. 12,349, 3-30-99; Ord. 13,124, 8-28-02; ORD-08-00109, 10-7-08; ORD-12-00035, 3-28-12) (Am. by Ord. 9326, 11-13-87) (Sec. 27.04(2)(g) Rescinded & Substituted by Ord. 4832, 1-16-75; Am. by Ord. 12,069, 3-30-99) (Sec. 27.04(2)(h) Am. by Ord. 9326, 11-13-76) (Am. by Ord. 9326, 11-13-87) (Cr. by Ord. 5439, 3-30-76; Am. by ORD-11-00063, 5-4-11; Am. by ORD-19-00004, 2-14-19)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.