§ 239-1 — Detached Private Garages
Milwaukee Code of Ordinances (Volumes 1-3 revised through Common Council action of Sept. 22, 2026) · Milwaukee Code of Ordinances § 239-1
Corpus is an independent public-information project, not the official City of Milwaukee website. Stable reference: corpuslaw.us/code/23ab0e34-878e-422b-9e45-745fea2df0c0
239-1. Detached Private Garages.
1. GENERAL REGULATIONS. a. An automobile shall not be placed or stored in any building or structure except as permitted and regulated in this code. b. Detached private garages on premises used entirely for residential purposes and located on premises occupied by no more than 2 families, may be of Type VB construction or better. 2. LOCATION. a. Detached private garages shall be located on premises as regulated in ch. 295 and as follows: a-1. When swinging doors are used, not less than the width of such doors from street to alley lines. a-2. When of Type VB construction, not less than 10 feet from any residence building, except that such distances may be reduced to not less than 3 feet when the exterior walls of such garage adjacent to a residence building are protected with not less than one-hour, fire resistant construction. a-3. When of Type IIB unprotected noncombustible frame construction, not less than 6 feet from any residence building. a-4. When of Type IA, IB, IIA, IIIA, IIIB, IV or VA construction, not less than 3 feet from any residence building. b. The regulations in par. a apply to private garages which are constructed as an ancillary use to one and two-family dwellings. 4. FOOTINGS AND FOUNDATIONS. Footings and foundations as regulated in chs. SPS 361 and 362, Wis. Adm. Code, shall be provided for all private garages, except that private garages of Type IIB, VA or VB construction may be provided with a continuous floating slab of reinforced concrete not less than 4 inches in thickness. Reinforcement shall be a minimum of number of 10 (6X6) inch wire mesh or fiber reinforced concrete. The slab shall be provided with a thickened edge all around, 12 inches wide and 8 inches below the top of the slab. The thickened edge shall have 2 continuous #4 horizontal reinforcement bars placed in the lower third of the thickened edge. Exterior wall curbs shall not be less than 8 inches above the adjoining grade. 5. FLOOR SURFACE. The floor in all private detached garages shall be of concrete construction. No openings or pits in the floor shall be permitted. 6. CONSTRUCTION. Private detached garages shall be constructed as follows: a. Load bearing foundation walls and piers, masonry walls and partitions shall be constructed as regulated in sub. 5. b. Detached private garages of Type VA or VB construction shall be constructed as regulated in chs. Comm 61 and 62, Wis. Adm. Code, with the following exceptions: b-1. Studs may have a maximum spacing of 24 inches on centers. Doubling of studs shall not be required at jambs of openings less than 40 inches wide. b-2. Diagonal corner bracing may be applied on the inside surface of studs. b-3. Corner posts may consist of 2 2 by 4 inch studs or a single 4 by 4 inch stud. b-4. Top plate may be single, provided rafters are placed over studs and plates are lapped to provide ties. b-5. Sheathing and sheathing paper may be omitted. Siding may be applied directly to the studs. b-6. Interior wall and ceiling finish need not be provided when not required for fire protection. b-7. Horizontal bracing and collar beams may be 2 by 4 inches with a maximum spacing of 6 feet on centers. Private detached garages of Type IIB unprotected and noncombustible frame construction shall have a structural frame of the conventional hot-rolled structural steel shapes or approved light gauge steel and the exterior and interior walls and roof shall be made of metal or other approved noncombustible material. Metal when used for exterior or interior walls or the roof shall be of not less than No. 24 U.S. gauge corrosion-resistant metal or steel which has been painted, galvanized, enameled or covered with other approved integral weatherproof covering or treatment. 7. ELEVATION OF PRIVATE GARAGES. No permit shall be issued by the commissioner of city development for the construction of a private garage where the elevation of the floor at any point of the garage is less than 3 inches above the grade of the sidewalk or alley from which access by a motor vehicle is to be made or where the slope of the approach from the street or alley line is greater than 2 inches per foot. 8. DOORS. Detached private garages and accessory buildings designed or utilized for the storage of motor vehicles shall be equipped with operative doors at all entranceways. 9. HEATING APPLIANCES. a. Except as provided in pars. b to d all fuel-fired heating equipment, including but not limited to boilers, furnaces or water heaters, shall be isolated from the rest of the building by at least a 2-hour fire-resistive enclosure. b. Direct vent sealed combustion chamber appliances need not be enclosed with fire-resistive rated construction. c. Boilers up to 200,000 BTU input, water heaters up to 200,000 BTU input, furnaces and vented unit heaters may be used if the units are suspended at least 7 feet above the floor. d. Electric heating equipment may be used if it is of a listed or an approved type.
Ask a question about Milwaukee law
Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.
