§ 18-328 — Plastering
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-328
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/1ee8aa55-6167-4485-af4a-47c6dfeec5da
Sec. 18-328. - Plastering.
(a) Number of coats. Plastering with gypsum hard-wall, lime, or Portland cement plaster shall be applied in not less than three coats when applied over metal or wire lath and in not less than two coats when applied over other plaster bases permitted in this article. Lime or Portland cement plaster shall not be applied directly to fiber insulation lath or gypsum lath. (b) Thickness. Grounds shall be installed to provide for the following thicknesses of interior plaster, from face of plaster base to finished plaster surfaces, as regulated in Table J. Table J. Thickness of Plaster (Residential) Type of base | Plaster thickness (inches) Metal or wire lath ..... | ⅝ minimum Other approved types of lath ..... | ⅜ minimum Unit masonry and concrete walls ..... | ½ minimum Monolithic concrete ceiling ..... | ⅛ minimum, ⅜ maximum If monolithic concrete ceiling surfaces require more than three-eighths inch of plaster to produce desired lines or surfaces, metal or wire lath shall be attached thereto. (c) Application to masonry or concrete base. When masonry walls are plastered they shall be stripped, lathed and plastered to protect against moisture. (d) Weather protection. When interior plastering work is in progress, adequate ventilation shall be provided, and in freezing weather the enclosure shall be heated. Plaster shall not be applied to surfaces that contain frost.
(Code 1973, § 30.34.030)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.