Sec. 18-361. - Chimneys—General requirements.
(a) Height. Chimneys shall extend at least three feet above a flat roof and at least two feet above any portion of the building within ten feet. (b) Corbeling. No chimney shall be corbeled from a wall more than six inches, nor shall a chimney be corbeled from a wall which is less than 12 inches in thickness unless it projects equally on each side of the wall; provided, that in the second story of two-story buildings, corbeling of chimneys on the exterior of the enclosing walls may be equal to the wall thickness. Corbeling shall not exceed one-inch projection for each course of brick projected. (c) Change in size or shape at roof not permitted. No change in the size or shape of a chimney, where the chimney passes through the roof, shall be made within a distance of six inches above or below the roof joists or rafters. (d) Foundation. All masonry chimneys shall rest on a foundation located on permanently undisturbed soil, at least four feet below established grade, or shall be supported on fireproof construction. No masonry chimney shall rest on or be hung or otherwise supported from combustible floor or wall construction. (e) Class A chimney required. When the source of heat requires one or more chimneys, it is required that one chimney shall be a class A chimney.
(Code 1973, § 30.39.010)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.