For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-1131 — Definitions

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 22-1131

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/1afcffa3-5fcd-49b3-9b80-05c0299e8f81

Sec. 22-1131. - Definitions.

The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: ASME means the American Society of Mechanical Engineers' Boiler and Unfired Pressure Vessel Code. ASOPE means the American Society of Power Engineers. Automatically controlled boiler means a boiler equipped with the following safety devices: (1) In the case of a low pressure boiler other than a hot water boiler: a. An automatic low water fuel cutoff installed in compliance with COMM 41.30 or ASME section HG-605. b. A pressure combustion regulator installed in compliance with ASME section HG-604. c. Electrical wiring, circuitry and controls, installed in compliance with ASME sections HG-631, HG-632 and HG-633 and including a manually operated remote heating plant shutdown switch or circuit breaker installed outside the boiler room. d. Controls and heat generating apparatus installed in compliance with ASME section HG-640. e. Pressure gauges installed in compliance with ASME section HG-601. f. Water level indicators and water level controls installed in compliance with ASME section HG-603. (2) In the case of a hot water boiler: a. An automatic low water fuel cutoff installed in compliance with COMM 41.30 or in compliance with ASME section HG-614. b. A temperature combustion regulator installed in compliance with ASME section HG-613. c. Electrical wiring, circuitry and controls installed in compliance with ASME sections HG-631, HG-632 and HG-633, including a manually operated remote heating shutdown switch or circuit breaker installed outside the boiler room. d. Controls and heat generating apparatus installed in compliance with ASME section HG-640. e. Pressure or altitude gauges installed in compliance with ASME section HG-611. f. Thermometers installed in compliance with ASME section HG-612. (3) In the case of a high pressure boiler: a. An automatic low water fuel cutoff installed in compliance with COMM 41.30 or in compliance with ASME section C6.301(b). b. A pressure combustion regulator installed in compliance with ASME section C6.301(a). c. Electrical wiring, circuitry and controls for the operation of the boiler or boilers installed in compliance with the state and city electrical codes. d. An automatic fuel-trip device installed in compliance with ASME section C6.201(13), C6.201(14) or C6.201(15). e. Pressure gauges installed in compliance with ASME section PG-60(f). f. Water level indicators installed in compliance with ASME section PG-60(a). Boiler means any device intended for use in heating water or other fluids, under pressure in order to generate steam or other vapors. Boiler horsepower means a unit equivalent to a maximum fuel input of 40,000 Btu's per hour, or a maximum electrical input of ten kilowatts per hour. COMM means the Wisconsin Administrative Code Rules of the Department of Commerce. High pressure boiler means a boiler on which the safety valves are set at a pressure of more than 15 psig and that exceeds the dimensions of a miniature boiler. Hot water heating boiler orhydronic boiler means a boiler in which no steam is generated from which hot water is circulated for heating purposes and then returned to the boiler and which operates at a pressure not exceeding 160 psig or a temperature of 250 degrees Fahrenheit at or near the boiler outlet. Low pressure boiler means a boiler on which the safety valves are set at pressures not exceeding 15 psig. Miniature boiler means a power boiler or high temperature water boiler which does not exceed any of the following limits: (1) Sixteen inches inside diameter of shell; (2) Twenty square feet of heating surface, except for electric boilers; (3) Five cubic feet gross volume exclusive of casing and insulation; (4) One hundred psig maximum allowable working pressure.

(Ord. No. 31-92, pt. 1, § 22.18.010, 10-20-92; Ord. No. 33-03, pt. 1, 1-20-04; Ord. No. 28-09, pt. 1, 2-2-10)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.