For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-507 — Gun range structure; safety requirements

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 22-507

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/621e5bb7-9b70-4b7b-a873-860cc36ba326

Sec. 22-507. - Gun range structure; safety requirements.

No gun range structure shall be licensed as a gun range unless it meets or exceeds the following standards: (1) Use and construction. The place to be licensed as a gun range shall be used only for the purpose of a gun range and not for any other purpose during any period that weapons are being fired or used. The construction shall meet or exceed the minimum recommendations of the United States Director of Civilian Markmanship and/or the recommended range construction of the National Rifle Association of America, for the class of range the license is to allow. (2) Targets; firing line. There shall be provided a target carrier system or device for running the targets back and forth between the firing line and the bullet stop on indoor ranges. The licensee shall not permit any person to go in front of the firing line during the progress of firing for any purpose. No person shall go in front of the firing line during the progress of firing. (3) Doors. All doors opening into the range, except those behind the firing line, shall be bolted from the inside at all times during which the gun range is in use. (4) Sound quieting treatment. Licensed premises which are located adjacent to property used in whole or in part for residential purposes shall be constructed in such a manner as to prevent the emission of unreasonable noise from shooting from being conveyed outdoors. (5) Range ventilation. An adequate exhaust ventilation system shall be installed on the range for the removal of smoke, lead dust, and gases from the combustion of powder. This standard can be met with the following basic characteristics in the ventilation system: a. An evenly dispersed air flow of 50 to 75 feet per minute from the rear of the firing line past the shooter's upper body. b. An even air flow across the firing line. c. Exhaust from the target area.

(Code 1973, § 22.28.060)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.