Sec. 50-394. - Installation requirements.

(a) Plans. Where required, a complete drawing of the system installation, including the hood(s), exhaust duct(s), and appliances, along with the interface of the fire-extinguishing system detectors, piping, nozzles, fuel shutoff devices, agent storage container(s), and manual actuation device(s), shall be prepared. (b) Review of plans; fee. All plans for automatic fire extinguishing equipment shall be submitted for review and approval by the fire prevention bureau prior to installation of the equipment. Two sets of plans and specifications shall be submitted to the bureau. One set shall be returned to the installer and if, sufficient, shall be stamped "approved by the bureau of fire prevention" with the date of such approval. The plan review fee shall be as set forth in the fee schedule as established by the common council. (c) Installation. (1) The system shall be installed by or under the direct supervision of a factory authorized representative. (2) Package units or individually designed units shall be installed in conformance with the limitations of the designers' or manufacturers' specifications. (d) Inspection; fee. A representative of the fire prevention bureau shall inspect all fire extinguishing systems installations prior to occupancy. The inspection fee shall be as set forth in the fee schedule as established by the common council. Occupancy shall not be approved until the installation is approved. (e) Maintenance. (1) All fire extinguishing systems shall be inspected semiannually by a factory authorized service person, except for occupancies open during no more than six months per year, which shall be inspected in their open season. A certificate of this inspection, of the work which has been performed, signed by the service person, shall be submitted to the fire prevention bureau within ten days of inspection. (2) A service person who inspects a fire extinguishing system shall attach thereto a durable tag which clearly indicates the year of manufacture. The date of installation of the fusible links shall be marked on the system inspection tag, and the tag shall be signed or initialed and dated by the service person, indicating the date of completion or last inspection/service.

(Ord. No. 28-04, pt. 1, 9-7-04; Ord. No. 0028-19, pt. 85, 11-12-19)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.