1315.08 - TRANSPARENCY.
A. Transparency is the required area of a building's façade to be occupied by fenestrations, also known as windows and doors. Transparency is measured as follows: 1. Ground floor transparency is calculated based on the total façade area located between two feet and eight feet above finished ground floor level. 2. Upper floor transparency is calculated based on the total façade area located between the surface of any floor to surface of the floor above it or, if there is no floor above, from the surface of the floor to the top of the wall plate. [image omitted; see the official code] Figure 1315.O: Ground and Upper Floor Transparency Area 3. Window transparency area. The entirety of a window, to the outer extent of the frame, may be used to calculate transparency area with the following exceptions: a. A mullion or other opaque element between sashes or fixed panes, greater than eight inches in width shall not count for the transparent area of a window. This shall include the separation between transom windows and other windows below them. 4. Door transparency area. The entire area of the door, not to include the casing or frame, may be used to calculate transparency area. A transom window above a door shall be included in the area of the door with the following exception: a. The separation between the transom window above the door and the door itself is not greater than eight inches, to include the casing and mullion. If the separation is greater than eight inches, the opaque area between the transom and the door is not included in the calculated transparency area. 5. Storefront and curtain wall transparency area. The entire area of a storefront and curtain wall, a non-loadbearing wall that is primarily glass with typically aluminum or wood mullions separating doors and panes of glass, may be used to calculate transparency area with the following exceptions: a. A mullion or other opaque element greater than eight inches within such a wall system shall not count for the transparent area of a storefront or curtain wall. b. If mullions or other opaque elements account for 20% or more of the total area of a storefront or curtain wall, the transparency shall be measured based upon the area of each pane of glass not covered by an opaque element and the area of the door itself. [image omitted; see the official code] Figure 1315.P: Area of a Window and Door That May be Used to Calculate Transparency; See also Section 1315.08.A.1 - Ground Floor Transparency B. Window qualifications. For any windows to be included in the transparency calculation, the glazing must meet the following criteria: 1. For ground floor glazing, the glazing must have a minimum 60% visible light transmittance (VLT) and no more than 15% visible light reflectance (VLR). 2. For upper floor glazing, the glazing must have a minimum of 40% VLT and no more than 15% VLR. 3. No interior obstructions are permitted to restrict the view to the interior with the exception of displayed merchandise and signs in compliance with article 1345. Blinds, curtains, or similar window treatments that are easily adjusted to control glare or privacy, as determined by the planner, do not count as obstructions. 4. Windows used in bathrooms, restrooms, dressing rooms, locker rooms, or similar spaces as determined by the planner may have tempered glass, laminated glass, or similar treatments to provide for adequate privacy for those spaces while still allowing for the transmission of light. C. Door qualifications. For any door to be included in the transparency calculation, the door must be part of a main entrance, open to and operable by customers or occupants during business hours in the case of a non-residential use, or operable at any time by occupants in the case of residential use. D. Ground floor blank wall width. The ground floor blank wall width is measured as any linear dimension of contiguous building wall on the ground floor that does not contain any fenestration. E. Front façade. The front façade is the street right-of-way facing façade for a structure. If there are multiple facades that face a street, the front façade will be determined by the planner based on the following criteria: 1. Which façade faces a more primary street. 2. Where the primary entrance is located. 3. Where hierarchical forms of the building are located to signify a more primary entrance if there are multiple, such as a large canopy covered walkway extending to the street or a large vertical extension of a parapet to signify where the entrance is. F. Corner side façade. The corner side façade is a street right-of-way facing façade on a corner lot that is not the front façade. G. Chamfered corner or beveled edge on buildings. A chamfered corner or beveled edge of a building, designed to achieve corner visibility on a corner lot or driveway entrance, shall be measured as follows: 1. If located on the corner of a lot where two rights-of-way intersect, the wall can be measured one of two ways. If the wall contains an entrance that is only for uses and spaces on the upper floor, the wall will be counted as a corner side façade. If the wall contains an entrance that is for ground level uses or spaces, the wall will be counted as a front façade. H. All fenestrations on the street facing facades must remain transparent to the interior. Windows and doors may not be covered unless for construction with an issued permit, or if the building is vacant and for a period of time until the building is no longer vacant. The covering of windows and doors shall be in compliance with article 1741 and article 1743. I. Transparency exceptions. Exceptions for transparency are as follows: 1. Common walls. The portion of a structure that is a common wall is exempt from any transparency requirements.
(Ord. No. 2020-O-15, 6-22-20)
Ask a question about Huntington law
Corpus searches the Huntington sections it holds and shows the ones that match, with their citations. Free, no sign-in.