1387.09 - DRAINAGE DESIGN.

Drainage designs will be based on the procedures and methods for hydrology studies outlined in the West Virginia Division of Highways Drainage Manual. Minimum design storm standards, unless directed in writing are: Storm sewer - Ten-year storm. Roadway culverts - (major roadway) 25-year storm (minor roadway) ten-year storm. Detention ponds - Two-year storm. Drainage ditches - Two-year storm (minimum).

(Ord. 12-26-00)