17.104.050 - Electrical outlet.
An electrical outlet supplying nominal 120/240 volts, fifty pedestal, shall be provided for each unit space with readily accessible means of disconnecting the electrical supply. A ground connection shall be provided with clamps or other facilities for connection between ground and the body of the recreational vehicle, if of metal. Such ground connection shall be a minimum of No. 6 stranded copper conductor or its equivalent, and shall be connected to a metallic water pipe or other approved ground in accordance with the National Electrical Code, latest edition. No main power supply line shall be suspended less than eighteen feet above the ground.
(Ord. 5-91 (part), 1991)