§ 17.94.130 — Design standards
Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 17.94.130
Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/ac5b40b3-8c51-4272-8087-b3cbb4133390
17.94.130 - Design standards.
A. Purpose. These standards have five primary functions: 1. To support the form-based zoning by providing additional design direction; 2. To direct developers or business owners wishing to propose expansions, renovations or new construction of buildings or parking within the project area; 3. To assist city staff and city officials in reviewing development proposals; 4. To support the goals, policies, land use and transportation plans crafted as part of the Old Yellowstone District and South Poplar Street Corridor; and 5. To create durable, high quality development, including office, retail and life cycle housing for a range of income levels. B. Application. The design standards for the Old Yellowstone District and South Poplar Street Corridor shall apply to the following activities on all types of institutional, commercial, mixed use and residential facilities: 1. New building construction; 2. Exterior remodeling affecting more than fifty percent of street facing facades or additions of over fifty percent of the existing floor area, not including routine maintenance, such as repainting or roof repairs within a single one-year timeframe; 3. Interior remodeling over fifty percent of existing structure floor area and affecting existing doors and fenestration within a single one-year timeframe; 4. New surface parking of more than four spaces or expansion of existing parking lot totaling more than four parking spaces; 5. New signs must comply with sign regulations herein. C. Design Review. Project sponsor (developer or owner) shall meet with the community development director to discuss the proposed project prior to making a formal submittal for approval. Accepted submittals will be reviewed by the city for compliance with these design standards as a part of the site plan review process. D. Relief. 1. Relief from a specific building-material-related design requirement may be granted by the Architectural Review Committee on an individual basis for new or different construction materials not permitted or addressed by these design standards if the applicant demonstrates that such building materials meet the design objectives of the Old Yellowstone District and South Poplar Street Corridor Form-Based Code. Approval of alternate building materials by the Architectural Review Committee shall include findings supporting the approval and shall be based on compliance with one or more specific objectives or goals of the Old Yellowstone District and South Poplar Street Corridor Form-Based Code. 2. If an applicant requests relief, and after the Architectural Review Committee has made its findings, is aggrieved by the decision of the Architectural Review Committee, said applicant may appeal the Committee's decision pursuant to Section 17.94,020. E. Reference and Precedence. These design standards have been coordinated with information established in the city of Casper Design Standards for Commercial Downtown Streetscape and Parks dated September 2005. Additional guidance on aspects of these site development standards such as public streetscape, parking lot, bikeway and park facility design can be obtained from consulting the city of Casper Design Standards for Commercial/Downtown Streetscape and Parks (Chapter 16.17 of this code). In the event of discrepancies between the two documents, the West Central and South Poplar Street Corridor Plan, dated September, 2007, as may be amended from time to time, design standards shall take precedence. BUILT FORM STANDARDS Building Placement OBJECTIVE: To maintain and reinforce a recognizable, consistent street edge. Buildings shall have a well-defined front facade with primary entrances facing the street. Buildings shall be aligned so that the dominant lines of their facades parallel the line of the street and create a well-defined street edge. Placement shall meet the established building setback as defined in the building envelope standards for the specified building type as located on the regulating plan. In addition, portions of the facade may be set back up to five additional feet beyond the allowable maximum set back to emphasize entries, provide increased space for plantings or to create areas for outdoor dining and gathering. Placement of the main level of residential buildings eighteen to twenty-four inches above the elevation of the front sidewalk is encouraged to provide greater separation and security. Additional side or rear entries shall meet grade and shall serve as the "accessible" entrance. At intersections, buildings should "hold the corner" — that is, have street facades at or near the sidewalk on both streets. [image omitted; see the official code] Place building entrances facing the primary street. [image omitted; see the official code] Entry recessed to provide area for outdoor dining. [image omitted; see the official code] Example of building properly set to the corner. BUILT FORM STANDARDS Facades OBJECTIVE: To employ visually legible building proportions that support pedestrian interaction, are scaled to provide a distinct first story, define the street edge and provide visual continuity. In general, buildings over two stories shall have a well-defined base, middle and top. The base, or ground floor, shall appear visually distinct from upper stories, through the use of a change in building materials, window shape or size, an intermediate cornice line, an awning, arcade or portico, or similar techniques. It shall be recognized that buildings will be viewed from a variety of vantage points. Consequently, the placement of doors, windows, balconies, changes in materials or roof height, etc. shall be designed to provide an attractive and harmonious design from the front, side, rear and top. Building tops shall be articulated with discernible cornice lines, parapets and/or fascias. [image omitted; see the official code] Buildings with recognizable layers — base, middle and top BUILT FORM STANDARDS Building Width and Facade Articulation OBJECTIVE: To add visual interest and variety by avoiding long, monotonous facades. New building facades, including parking garages, shall have a pedestrian scale aesthetic. This can be accomplished by establishing a layering of rhythmic patterns and architectural elements such as windows, columns, roof lines, building materials and colors. "Flat" facades shall be avoided; historic structures exhibit more of the desired play of light and shadow on a building; new development shall create more of a visual impact in ways similar to that of historic structures. The primary facade(s) (viewable by the public from streets and parking lots) of all buildings shall be articulated into distinct increments through the following or similar techniques: •Stepping back or extending forward a portion of the facade •Use of different textures or contrasting, but compatible, materials •Division into storefronts with separate display windows and entrances •Arcades, awnings, window bays, balconies or similar ornamental features •Variation in roof lines to reinforce the articulation of the primary facade [image omitted; see the official code] Changes in material and color, along with multiple entrances, break this block-long facade into smaller, more human scale increments. [image omitted; see the official code] Well proportioned, rhythmic facade using uniform exterior building material (painted concrete). [image omitted; see the official code] Facades divided into smaller, human scale increments that also reflect the building's interior organization and ownership pattern. BUILT FORM STANDARDS Building Height OBJECTIVE: To support development economics with adequate density and intensity, create an increased sense of enclosure, diminish the perceived width of the street, and maximize opportunities for upper-story offices and housing. Multi-story buildings (at least two stories) built to the maximum heights permitted by zoning (Building Envelope Standards) are encouraged. Stepping portions of upper stories back from the line of the front facade to provide areas for outdoor terraces, rooftop patios, etc. is encouraged. This is especially important for buildings facing the river front. New single story commercial building types with flat roofs shall have a minimum cornice height of twenty feet to better define the street. [image omitted; see the official code] [image omitted; see the official code] Stepping upper stories back from front, the plane of the primary facade provides areas for outdoor balconies, rooftop gardens and more sunlight to reach the street corridor. [image omitted; see the official code] Example of mid-rise, stacked flats building type. BUILT FORM STANDARDS Roof Design OBJECTIVE: To provide a visual terminus to the building, reduce monotony and reflect interior and exterior patterns of use or ownership. Buildings may be designed with pitched and/or flat roofs. Flat roofs shall be defined with a discernible cornice line. Variations in roof type, height, and/or distinct, separate roof segments shall be considered as a means of creating greater visual interest, identifying changes in use, areas of ownership or reducing monotony. Pitched roofs such as gable, hip, shed or mansard roofs shall be clad with highly durable, fire resistant materials, such as standing seam metal, slate, ceramic or composite tiles. Use of asphalt rolls or shingles is strongly discouraged. Use of green roofs for reductions in heat island effects, building energy consumption and stormwater management is highly encouraged. [image omitted; see the official code] Green roofs are an effective way to reduce energy costs and heat island effects. [image omitted; see the official code] Roof designs from top down: Mansard, hip, flat and gable. BUILT FORM STANDARDS Transparency: Window and Door Openings OBJECTIVE: To reflect the character of the corridor's historic commercial heritage, enliven the streetscape and enhance security by providing views into and out of buildings. For nonresidential or mixed-use buildings: • Window and door openings shall comprise at least sixty percent of the length and at least thirty percent of the area of the ground floor of the primary street facade. • A minimum of twenty percent of the ground level of side and rear facades not fronting a public street shall consist of window and door openings. • A minimum of twenty percent of all sides of upper story facades shall consist of window or balcony/door openings. • New and renovated buildings with alleyway frontage shall include windows to allow views into the alleyway for added surveillance. For residential buildings: • A minimum of twenty percent of primary (street-facing) facades and fifteen percent of other facades, including rear and upper stories, shall consist of window and door openings, providing residents within the buildings light, air and visual connections to activity on the sidewalk, street and alleyway. [image omitted; see the official code] Large, transparent shop front windows are common throughout downtown Casper. [image omitted; see the official code] Traditional application of transparent, store front type windows at ground level and transparent double-hung windows on second floor. [image omitted; see the official code] Residential buildings with 20% of facade featuring windows and doors at group level; 15% of second story. Windows and door openings shall meet the following requirements: • Windows shall be designed with punched and recessed openings, in order to create a strong rhythm of light and shadow. • Window shape, size and patterns shall emphasize the intended organization of the facade and the definition of the building. • Mirrored, dark tinted, opaque or glass block shall not be used on street-facing facades as major window openings. Glass on street facing doors and windows shall be clear or lightly tinted, allowing views into and out of the interior. Glass block may not contribute to transparency requirements, but may be used as architectural adornment. • Windows on all facades of buildings shall meet the requirements of the Wyoming Building Energy Codes for energy efficiency. [image omitted; see the official code] The historic Coca-Cola building displays recessed and punched window openings. [image omitted; see the official code] Example of building with individual window openings deeply recessed or "punched" through the facade. [image omitted; see the official code] Recessing windows into the facade adds depth and visual interest. BUILT FORM STANDARDS Entries OBJECTIVE: To establish the visual importance of the primary street entrance, and to ensure that entries contribute to the visual attractiveness of the building and are readily visible to visitors. Nonresidential or Mixed-Use Buildings Primary building entrances on all buildings shall face the primary abutting public street or walkway, or be linked to that street by a clearly defined and visible walkway or courtyard. Additional secondary entrances shall be oriented to a secondary street or parking area. Residential entries shall be separate and distinct from commercial entrances. In the case of a corner building or a building abutting more than one street, the street with the higher functional classification shall be considered primary. The main entrance shall be placed at sidewalk grade. Entries shall be designed with one or more of the following: • Canopy, portico, overhang, arcade or arch above the entrance. • Recesses or projections in the building facade surrounding the entrance. • Display windows surrounding the entrance. • Architectural detailing such as brick work or ornamental moldings. • Planting areas, pots or window boxes for seasonal landscaping. Canopies or awnings protecting the primary entrance shall be set at least seven feet above sidewalk grade, and project no greater than three feet into the walk zone of the public streetscape. [image omitted; see the official code] Primary entrances shall be oriented to the primary street. Secondary entrances shall be provided to the side and back of buildings. [image omitted; see the official code] Covered entry, oriented away from the prevailing winds to maximize protection and comfort. Residential Buildings Primary building entrances on all buildings shall face the primary abutting public street or walkway, or be linked to that street by a clearly defined and visible walkway or courtyard. Additional secondary entrances may be oriented to a secondary street or parking area. Porches, steps, pent entryway roofs, roof overhangs, hooded front doors or similar architectural elements shall be used to define the primary entrances to all residences. When the primary residential entrance is accessible by steps, a secondary at-grade entrance shall be provided. [image omitted; see the official code] Separate entries set at grade for residential high-rise and townhomes. [image omitted; see the official code] Separate entrances for multifamily buildings helps to reduce monotony and promote individuality. BUILT FORM STANDARDS Rear Facades and Entries OBJECTIVE: To improve the appearance of rear facades, orient customers parking or walking to the rear of buildings, and provide safe and convenient access to all building entries. Rear facades shall be designed as an integral part of the overall building with similar materials and detail treatments. If parking is placed to the rear of a building, the building's rear facade shall include elements such as awnings, landscaping and small wall signs identifying businesses. If customers, visitors and/or tenants park to the rear of the building, a well-defined and lighted rear entrance is required. If no rear building entrance is provided, a signed and lighted walkway to the front or side building entrance shall be provided. [image omitted; see the official code] Buildings with rear off-street parking and loading shall provide windows, walkways and lighted entrances. [image omitted; see the official code] Well-designed commercial entrance serving customers using off-street parking behind building. [image omitted; see the official code] Rear entrances located along an alleyway designated for pedestrian use. BUILT FORM STANDARDS Parking Structures OBJECTIVE: To ensure scale and form will achieve visual continuity with surrounding buildings, while providing neighborhood-supportive uses along the street edge. The design of parking structures within the corridor shall comply with these design standards. At least sixty percent of the ground floor facade abutting any street shall be occupied by commercial or office uses. Facades shall be designed and architecturally detailed like other commercial buildings within the corridor. (see section on facade articulation). The structure's exterior shall feature horizontal detailing to hide angled ramps within the structure's interior. Windows or other openings shall be provided that echo those of surrounding buildings. Screening of refuse facilities and mechanical equipment shall be accomplished by locating the facilities internally in a partitioned enclosure. Parking facilities within the corridor shall incorporate CPTED (Crime Prevention Through Environmental Design) by utilization of both active and passive security design features, including but not limited to: • Parking Layout — maximize horizontal floor area; avoid layouts that require parking on angled ramps. • Lighting — design that meets illuminance, uniformity and glare standards of the IESNA (Illuminating Engineering Society of North America). • Natural Surveillance — openings in the facade on all sides of a structure and low landscape plantings placed away from the base of the structure. • Access control — transparent decorative metal fencing and minimization of pedestrian and auto ingress/egress. • Emergency communication — panic buttons, emergency telephones, intercoms, sound-activated surveillance systems, CCTV and security personnel. • Locate stairways at corners and enclose with transparent glass. [image omitted; see the official code] Parking structures with street facing liner shops, well articulated facade and corner stair tower. [image omitted; see the official code] Parking structures with street facing liner shops, well articulated facade and corner stair tower. BUILT FORM STANDARDS Building Materials OBJECTIVE: To ensure that durable and authentic building materials are used in all forms of building construction. Buildings shall be constructed using local or regionally available, durable materials such as: • Brick • Natural stone • Manufactured stone • Textured, patterned and/or integrally colored cast-in-place concrete • Integrally colored, pre-cast CMU (concrete masonry units), provided that surfaces are molded, serrated or treated to give wall surfaces a three-dimensional texture. • Stucco or EIFS (exterior insulating finish system) above the ground line (plus two feet). • Architectural metal; pre-finished decorative panels such as store front systems, structural elements such as columns and beams and decorative support or trim members such as brackets or cornices. Materials to avoid: • Unadorned plain or painted concrete block. • Unarticulated or blank tilt-up concrete panels. • Pre-fabricated metal building systems. • Aluminum, fiberglass, asphalt or fiberboard siding. [image omitted; see the official code] Natural stone, common in Wyoming [image omitted; see the official code] Architectural metal, copper siding and fascia on stacked flats condominium. [image omitted; see the official code] Brick and EIFS above. BUILT FORM STANDARDS Rooftop Equipment OBJECTIVE: To ensure that views of rooftop equipment from public streets or pedestrian ways are minimized. All rooftop equipment shall be screened from view from adjacent streets, public rights-of-way and adjacent properties. Preferably, rooftop equipment shall be screened by the building parapet, or shall be located out of view from the ground. If this is not feasible, the equipment shall be grouped within a single enclosure. This structure shall be set back a distance of one and one-half times its height from any primary facade fronting a public street. Screens shall be of durable, permanent materials (not including wood) that are compatible with the primary building materials. Exterior mechanical equipment such as duct work shall not be located in primary building facades. [image omitted; see the official code] Example of screening equipment with roof forms. [image omitted; see the official code] Rooftop equipment screening panels integrated into building facade. BUILT FORM STANDARDS Building Colors OBJECTIVE: To ensure that building colors are aesthetically pleasing and compatible with their surroundings. Building colors shall blend with, or enhance surroundings. Principal building colors shall consist of subtle, neutral or muted colors with low reflectance (e.g., browns, grays, tans, dark or muted greens). No more than three principal colors shall be used on a facade or individual store front. Bright, complimentary colors shall be used only as accents. [image omitted; see the official code] BUILT FORM STANDARDS Architectural Detailing OBJECTIVE: To have new building design that enlivens building facades and contributes to a rich textured, human-scaled environment. Architectural details such as ornamental cornices, arched windows and brick with bands of contrasting color are encouraged in new construction. The contemporary adaptation of historic and vernacular residential, institutional and commercial styles found in Casper is encouraged. [image omitted; see the official code] Terminate materials at an inside corner [image omitted; see the official code] Avoid termination of materials at an outside corner. [image omitted; see the official code] BUILT FORM STANDARDS Franchise Architecture OBJECTIVE: To have new building design that is supportive of the urban design goals of the city, and that responds to the corridor's walkable development pattern. Franchise architecture (building design that is trademarked or identified with a particular chain or corporation and is generic in nature) is prohibited, unless it employs a traditional storefront commercial style. Franchises or national chains shall follow this code to create context-sensitive buildings that are sustainable in that they can be reused by other types of business. [image omitted; see the official code] BUILT FORM STANDARDS Awnings OBJECTIVE: To encourage the use of awnings as a way to shelter customers, residents and other pedestrians; reduce glare and conserve energy; and, provide additional accent color to building facades. Where awnings are used, canvas, fabric or vinyl awnings are preferable. If glass or metal awnings are employed, they shall complement the building's architectural character and aesthetic. All awnings shall extend beyond the facade no greater than three feet. The bottom of a window awning shall be set at least seven feet above the public sidewalk. Back lighted vinyl awnings and canopy signs shall not be used. [image omitted; see the official code] BUILT FORM STANDARDS Architectural Arcades and Balconies OBJECTIVE: To provide sun and weather protection and increase opportunities for people to see and be seen. The use of ground floor architectural arcades to provide pedestrian connections between facilities is encouraged. Upper floor balconies and terraces are encouraged to provide opportunities for outdoor activities. Balconies fronting public streets shall not project into the public right-of-way more than five feet. Balcony supports such as columns or posts shall be located on private property. Architectural arcades shall be illuminated with wall or ceiling light fixtures for pedestrian safety and security. [image omitted; see the official code] SITE DEVELOPMENT STANDARDS Parking Lot Design OBJECTIVE: To ensure parking lots are well-designed and constructed utilizing civil engineering and landscape architecture "best practices," including adherence to the principles of Crime Prevention Through Environmental Design (CPTED), i.e., territoriality surveillance, activity support and access control. Parking lots shall be designed to promote efficient traffic patterns, minimize conflicts between vehicles and pedestrians and to proactively reduce the opportunity for crime. Paving treatments shall incorporate durable, long lasting materials. The use of pervious materials such as pervious concrete or paving stones is encouraged to minimize stormwater runoff. Stormwater runoff should be captured, when possible, and directed toward landscaped areas. Parking lots shall be lit evenly and adequately to ensure visibility at night for pedestrian and vehicle safety and to reduce opportunities for vehicle break-ins. Lighting shall comply with the standards outlined in the appendix. Parking lots shall be broken up into smaller areas located at the side and to the rear of buildings, whenever possible. When parking is located adjacent to a roadway, a landscaped buffer shall be provided (see "Landscaping and Screening, Parking Areas"). Lots shall be designed to incorporate intermediate planting beds, planting island and intermediate planting "fingers" to break up large areas of impervious surface. [image omitted; see the official code] Parking located at the rear of building. [image omitted; see the official code] Parking located at the side and rear of building. [image omitted; see the official code] SITE DEVELOPMENT STANDARDS Landscaping and Screening OBJECTIVE: To ensure surface parking lots are adequately landscaped with a variety of multi-seasonal plantings to buffer or soften the appearance of vehicles and mitigate the adverse environmental affects of impervious surfaces. Parking Areas Screening is required wherever parking lots front onto the public rights-of-way or are adjacent to residential and/or mixed uses including residential properties. Parking bays shall have landscape islands at each end, and bays in excess of fifteen spaces in length shall be divided by intermediate landscape islands. Landscape islands shall provide at least three hundred sixty square feet of area for planting trees, shrubs and/or groundcovers. Intermediate landscape "fingers" shall provide at least one hundred eighty square feet of planting area. A landscape buffer strip of a minimum five feet in width shall be provided between all parking areas and the public sidewalk. The buffer strip shall consist of drought tolerant shade trees, low shrubs or perennial flowers and a decorative fence or masonry wall. Plantings and parking lot screen walls or fences shall be no less than two feet and no more than three feet in height to allow views into and out of parking areas. [image omitted; see the official code] Parking located at the side and rear of building. [image omitted; see the official code] Minimum 5 foot wide landscape planting buffer provides effective screening of parking areas from walks and streets. [image omitted; see the official code] SITE DEVELOPMENT STANDARDS Pathways and Walks OBJECTIVE: To provide pedestrian connections between facilities, reduce internal vehicle trips within the corridors and support healthy living. All walkways within the corridor shall be designed and constructed in strict adherence to the Americans with Disabilities Act. Continuous sidewalks are required along all street frontages. The use of ground floor arcades to provide weather protected pedestrian connections between facilities is encouraged. Lighted sidewalks shall extend between rear or side parking areas and building entrances. Public sidewalks and boulevard areas along the corridor shall be enhanced with decorative pavement treatments, ornamental street lighting, streetscape furnishings, appropriately scaled landscaping as part of the design and implementation of the Old Yellowstone District and South Poplar Street Corridor, and in compliance with the Design Standards for Commercial/Downtown Streetscape and Parks (Chapter 16.17 of the Casper Municipal Code). The street grid shall be maintained and extended wherever possible. Where the street grid is interrupted by steep slopes or other topographic variations, walkways or stairways shall be built to maintain pedestrian continuity. Commercial developments shall strive to provide bicycle parking spaces in a convenient, visible, preferably sheltered location. [image omitted; see the official code] Covered walkway connects rear parking area to primary entrance. [image omitted; see the official code] Public sidewalk with shallow, adjacent front yards and entry walks. Use of low decorative metal fence and perennial plantings and small trees helps to demarcate the area as semi-private. SITE DEVELOPMENT STANDARDS Outdoor Seating and Dining OBJECTIVE: To provide space and facilities for outdoor gatherings, and provide opportunities to socialize. New commercial and mixed-use development projects shall provide semi-public or private areas for people to sit outdoors and be served food and beverages. These areas shall be established with either seasonal, moveable barriers such as lightweight decorative metal fence or railing systems, or permanently defined with low planters or screen walls. [image omitted; see the official code] Providing areas for people to sit and dine outdoors is good for business, promotes civility and strengthens sense of community. SITE DEVELOPMENT STANDARDS Site Development Standards Enclosures and Accessory Structures OBJECTIVE: To limit the use and direct the design of accessory structures, and refuse or mechanical equipment enclosures to be compatible with the principal structures they serve. New free-standing restaurants, nightclubs, and mixed-use facilities which includes commercial food service, constructed after the adoption of this ordinance, shall locate refuse containers and mechanical equipment in an enclosed structure. Said structure shall adhere to state and local health and safety codes, and approved design standards. Use of an accessory structure to support new multiple-family residential, office, and commercial/personal service facilities constructed after the adoption of this ordinance is prohibited. Newly constructed multiple-family, office, commercial or personal service facilities shall include a sufficient amount of space within the primary structure for the suitable storage. The design of the refuse or mechanical enclosure, carport or detached garage or the upgrade to an existing accessory structure shall be in character with, and constructed of, the same quality permanent materials as the principal building, or adopted design standards. No metal buildings or structures will be allowed. Any accessory structure shall be located on the same lot and in close proximity to the principal structure; provided, however, if an owner has two or more contiguous lots, the accessory structure may be located on a separate lot that is contiguous to the lot of the principal structure if all of the following conditions are met: (1) contiguous lots containing principal and accessory structures shall not be sold, transferred or encumbered separately; and (2) the owner, upon approval by the city and prior to the issuance of a building permit, shall execute a deed restriction in a form acceptable to the city that disallows the separate sale, transfer or encumbrance of the contiguous lots containing the principal and accessory structures. Where accessory structures exceed two hundred square feet in area, at least one-third of the building's exterior perimeter shall be landscaped in the same manner as the principal structure, and/or in compliance with the landscaping design standards. [image omitted; see the official code] Example of accessory structure for enclosing dumpsters designed to match the principle building. SITE DEVELOPMENT STANDARDS Site Lighting OBJECTIVE: To ensure quality lighting design through glare reduction, minimum overspill and the use of fixtures that promote the existing character of the Old Yellowstone District and South Poplar Street Corridor. Exterior light fixtures shall be selected and located to minimize glare and negative effects upon the night character of the Old Yellowstone District and South Poplar Street Corridor. Lighting of structures shall be minimized to reduce ambient light pollution from above and below. Lighting fixtures style shall be compatible with the architecture of nearby buildings. Lights attached to buildings shall be screened by the building's architectural features to eliminate glare and overspill onto adjacent properties. Public and private walkways shall be evenly illuminated to a level between one- and two-foot candles. Walkway light fixtures shall be between twelve and fourteen feet in height to provide human scale. Appropriate light sources: • Incandescent (for signs or on buildings) • Halogen • High pressure sodium • "Warm" metal halide • Cold season fluorescent Inappropriate light sources: • Neon, unless used as accent • Colored • Low-pressure sodium • Mercury vapor Appropriate light fixture types: • Pole mounted • Recessed • Wall mounted • Shield spotlighting Inappropriate light fixture types: • Internally lit awnings • Blinking or flashing • High mast (cobra head features) [image omitted; see the official code] Parking lot illumination shall consist of a combination of commercial grade parking lot and pedestrian style fixtures. Pedestrian fixtures shall be used for lighting internal parking lot walkways. Parking lot fixtures shall be employed to illuminate parking bays and drive aisles. Parking lot illumination shall achieve levels to provide safety while minimizing over-lighting and excessive spillover of ambient light onto adjacent properties. Cutoff fixtures shall be located below the mature height of trees in parking lot islands. This will prevent ambient "glow" or light pollution onto adjacent properties. Evenly distributed illumination shall be provided to provide safety and security. See appendix for additional information on lighting parking lot facilities. [image omitted; see the official code] Example of pole mounted, hat-box style fixture with engineered cut-off luminaire to provide even distribution and reduce glare. [image omitted; see the official code] SITE DEVELOPMENT STANDARDS Signs Applicability: These signs requirements are applicable to all new signs and the modification or reconstruction of existing signs in the Old Yellowstone District and South Poplar Street Corridor (OYDSPSC). New signs that comply with OYDSPSC design standards are required when there is a change of use in the principal building. No new sign will be allowed on existing, noncompliant sign structures, except as provided for off-premises signs (billboards). Sign permit applications will be reviewed by the architectural review committee for their consistency with these requirements and other applicable standards contained in the city's sign code (Title 17). The purpose of these requirements is to establish criteria for the creation of well-designed signs and further clarify and support the intent of the OYDSPSC design standards by providing examples of the city's expectations for well-designed, consistent signage that is pleasing in appearance and promotes a high-quality environment. OBJECTIVE: To achieve sign designs that harmonize and enhance the architectural, structural or landscape features of the associated facility and to enliven the resident and visitor experience. In addition to the zoning ordinance, signs shall meet the intent of these standards. • Provide creative, high quality signage that positively contributes in the improvement of the visual environment, expression of local character, and development of a distinctive image. • Enhance the building's architectural design. • Consider the scale and proportions of the building. • Provide property owners with an effective means of communication without creation of sign clutter. General Standards 1. Compatibility a. Large signs that dominate a building facade or streetscape are prohibited. Signs shall be designed to be compatible with building design in terms of relative scale, overall size, materials and colors. b. Signage elements shall incorporate materials, colors and shapes that appropriately reflect and complement the building's architectural style and the surrounding environment. 2. Legibility a. Use a brief message. b. Avoid hard-to-read intricate type-faces, and limit the number of letter styles. The number of lettering styles should be limited in order to increase legibility. A general rule is to limit the number of letter types to no more than two for small signs (up to ten square feet), and three for larger signs. c. Limit the area of the sign devoted to text. Lettering and logos shall not occupy more than seventy-five percent of the sign face. [image omitted; see the official code] d. Use significant contrast. If there is little contrast between the brightness or hue of the message and its background, it will be difficult to read. e. Use of symbols and logos is permitted. f. Avoid large areas of blank space. Signs with more than fifty percent of the sign area left blank shall be avoided. Location and Size a. Signs shall be designed to relate to the architectural features of the building and to create visual continuity with other storefronts in the same or adjacent buildings. b. Signs shall be placed at or near the public entrance. Signs shall be placed to indicate the location of accesses to a business. c. Signs shall be sized consistent with the proportions of the building's facade. Color Signs shall be limited to no more than three colors on a single sign. [image omitted; see the official code] Illumination a. Internally illuminated cabinet signs with translucent panels shall be prohibited. Utilization of a direct source of light (e.g., spotlight) is permitted. Light fixtures supported in front of the structure cast light on the sign and generally a portion of the face of the structure as well, thereby emphasizing the continuity of the structure's surface. [image omitted; see the official code] b. Back-lit, solid letters are encouraged. Signs consisting of opaque individually cut letters mounted directly on internally illuminated cabinet signs with translucent panels shall be prohibited. Individually illuminated letters, either internally illuminated or back-lit solid letters (reverse channel), are permitted. c. Signs that use blinking or flashing lights are not permitted. Materials Sign materials shall be selected with consideration for the architectural design of the building's facade. Materials utilized shall be durable, and the following materials are permitted: • Wood (carved, sandblasted, etched, properly sealed and painted, or stained). • Metal (formed, etched, cast, engraved, and properly primed and painted or factory coated to protect against corrosion). • Neon tubing. [image omitted; see the official code] Design Standards by Sign Type Wall Signs a. Wall signs shall not project from the surface upon which they are attached more than twelve inches. b. Wall signs and "ghost" signs painted directly on a structure are appropriate. c. The maximum total wall signage per facade shall not exceed two square feet per linear foot of building facade length of the wall on which it is to be located. In no case shall total wall signage exceed a maximum of three hundred square feet for any building. Projecting Signs a. The use of small, pedestrian-oriented signs along streets, walkways and in alleys (subject to the height standards in subsection f., below) is permitted. Projecting signs shall be used for ground floor uses only. On a multistoried building, the sign shall be suspended between the bottom of the second story windowsills and the top of the doors or windows on the first story. On single-story buildings the top of the sign should be in line with the lowest point of the roof. The projecting sign shall be hung at a ninety degree angle from the face of the building. b. Sign support brackets shall be compatible with the architectural design of the building. Decorative iron and wood brackets are permitted. c. Internal illumination of projecting signs is prohibited. d. Establishments with frontage on a street, alley or public walkway are permitted one projecting sign each, per street frontage, alley or public walkway. e. Projecting signs shall not be over ten square feet in size. f. Projecting signs in alleys shall be a minimum of fourteen feet above the surface of the alley. [image omitted; see the official code] [image omitted; see the official code] Awning Signs a. Awnings are limited to first and second floor uses only. Awnings shall be mounted on the building in such a way that they project over individual windows and door openings. b. Backlit, translucent, internally illuminated awnings are prohibited. c. Sign area or sign lettering shall comprise no more than thirty percent of the total exterior surface of an awning. Any graphic logo or text printed on an awning will be counted toward the total maximum allowable sign area. Window Signs Window signs shall not cover more than twenty-five percent of the area of each window. [image omitted; see the official code] Freestanding Signs (Monument Signs) a. The maximum number of freestanding signs is one per street frontage. b. All free standing signs shall be monument-type (solid base). Pole and pylon signs are prohibited. c. Monument signs may be internally illuminated, however, the sign copy should be the only portion of the sign face that is illuminated. The sign background or field should be opaque with a nongloss, nonreflective finish. d. Monument signs shall be placed perpendicular to the street, and so they do not obstruct sight lines at driveways or intersections. e. Monument signs shall incorporate landscaping at their base, in accordance with the landscaping regulations found in the appendix of the Old Yellowstone District and South Poplar Street Corridor Form-Based Code. f. Monument signs shall conform with the following: • Maximum height - eight feet. • Maximum sign area - fifty square feet. [image omitted; see the official code] Roof Signs [image omitted; see the official code] A sign located on the roof that by its construction materials, age, prominent location, unique design or craftsmanship, provides historic character, individuality, and a sense of place or orientation regarding clues to the building's history may be permitted in the Old Yellowstone District and South Poplar Street Corridor. Roof signs may be permitted by the architectural review Committee if demonstrated that the following requirements are met: a. The maximum number of roof signs is one per primary structure. b. Roof signs shall only apply to buildings with at least an average of twenty feet of vertical height from grade to parapet or roofline. c. Roof signs are allowed one historic feature, such as a logo or brand mark, not to exceed thirty-two square feet in area. d. Roof signs are only allowable on flat roofs. e. Roof signs shall not extend beyond the fascia, parapet, or roofline of the subject building. f. Roof signs shall only be one-sided. g. Roof signs should be an architectural feature of the historic building and not the primary form of advertising. h. Cabinet signs and electronic message centers are not permitted. i. Lighting shall be consistent with the vintage character of the sign. Roof signs may consist of internally illuminated individual letters; however, the sign copy should be the only portion of the face that is illuminated. Lighting may be exposed neon on a decorative background or from an external source that is consistent with the architectural style of the building. Flashing lights are discouraged. j. Lighting shall be downward facing to prevent light trespass and pollution. [image omitted; see the official code] [image omitted; see the official code] k. The maximum total roof signage shall not exceed the following ratios: Roof Sign Standards | Max. a. Supporting structure | 30% of vertical height of building b. Lettering height | 15% of vertical height of building c. Sign length | 70% of ridge length d. Feature | 32 square feet e. Total sign square footage - single-tenant | 1 square foot per linear foot of building facade length f. Total sign square footage - multi-tenant | 3 square feet per linear foot of building facade length [image omitted; see the official code] SITE DEVELOPMENT STANDARDS Off-Premises Signs A total of five off-premises, freestanding signs existed at the time of the adoption of the Old Yellowstone District and South poplar Street Corridor Form-Based Code, and were generally located at: • the northeast corner of Poplar Street and West Collins Drive; • adjacent to and west of 800 West Collins Drive; • on Collins Drive, east of South Walnut Street at 600 West Collins Drive; • on British Petroleum property immediately southeast of the South Poplar Street bridge; and • on West First Street, immediately west of the North Platte River bridge. Those signs may remain at their current locations or move to new locations within the district; provided, however, that the total number of off-premises signs in the district cannot exceed five. In addition, off-premises sign spacing shall comply with Section 17.96.050(I) of the Casper Municipal Code. Additional off-premises signs at new locations are prohibited. If existing signs are reconstructed, (including reconstruction of the sign structure or pole, or changes or upgrades to a faulty or degraded structure) they must comply with the following design standards: Size Off-premises sign faces shall not exceed ten feet in height, and twenty-three feet in width. The entire sign structure shall not exceed fifteen feet in height above the adjacent road grade. The opening from the bottom of the sign face to the ground shall be enclosed with lattice, wood or stone. [image omitted; see the official code] [image omitted; see the official code] Landscaping The base of the sign shall include a minimum of one hundred eighty square feet of irrigated landscaping that spans the entire width of the sign structure. Acceptable landscape materials are in the appendix of the Old Yellowstone District and South Poplar Street Corridor Form-Based Code. SITE DEVELOPMENT STANDARDS Fences and Screen Walls OBJECTIVE: To provide exterior enclosures or barriers that harmonize with the architectural design of their associated facilities, and enhance the aesthetics of surrounding environment. Frontages Decorative fencing or screen walls for entry courtyards or outdoor seating areas located between buildings and the primary street frontage, to include corner lots, shall not exceed forty-eight inches in height, be at least sixty percent transparent and be limited to the following materials: • Painted or sealed architectural metals such as wrought iron pickets or rails, cast or cut, and patterned screens supported by appropriately-sized structural systems. • Stone and/or brick veneer wall systems supported by appropriately-sized structural backup walls and subsurface foundations. • Wood, chain link, plastic, vinyl fiberglass pickets and/or corrugated metal panels are prohibited as a dominant material, but combinations of these materials, with the exception of chain link, may be allowed as long as they meet the site development standards identified in the Form Based Code and comprise not more than forty percent, in total, of the face area of the fence Side, Rear Yards, and Rear Yards on Alley or on Through Lots Fencing and screen walls for enclosing side yards, back patios or rear courtyards, or patios or yards on through lots, may be opaque and shall not exceed eight feet in height. The meaning of "through lots" in the Form Based Code has the same definition as in Section 17.08.010 of the Casper Municipal Code. Fences that are greater than six feet in height require a building permit. Fences shall be limited to the following materials: • Same materials as for frontages but also including painted wood or stained wood. Fences made solely of wood, chain link, plastic, vinyl fiberglass pickets, and/or corrugated metal panel are prohibited; but, combinations of these materials, with the exception of chain link, may be allowed as long as they meet the site development standards identified in the Form Based Code and comprise no more than forty percent, in total, of the face area of the fence. • Where fences and screen walls, located at the rear entry, are over six feet in height, the fence or screen wall must be designed into distinct increments through the following or a combination of or similar techniques: ;circle; Variation of fence or screen wall setback. ;circle; Using different textures or contrasting, but compatible, materials. ;circle; Incorporation of bases of contrasting, but compatible materials and/or planters and/or plant alcoves which shall receive irrigated landscaping materials. ;circle; Variations in the height (to allowable limits) and/or material of the fence so as to include and/or feature landscaping elements such as, but not limited to, earth berms, garden structures, gates, pergolas, or other appropriate elements of interest. Incorporating landscaping features into the fence or screen wall. ;circle; Variations in the transparency of the fence through the use of arcades, awnings, openings, windows or window bays, ledges, trellises or other ornamental features. ;circle; Varying the top line of the fence or screen wall to reinforce the articulation of the primary building facade. ;circle; A setback of at least five feet from the sidewalk, buffered with landscaping in accordance with the design standards outlined in the Form Based Code. Parking Lots Parking lot screen walls and fences shall be no less than two feet, and no more than three feet, in height to allow views into and out of the parking area. All fencing projects must first complete the fence or building permit application available in the community development department, and then arrange for a review and approval of the fencing project by the architectural review committee. [image omitted; see the official code] [image omitted; see the official code] Use of architectural metals for entry courtyards or primary street frontages. [image omitted; see the official code] Variation of fence or screen wall setback. [image omitted; see the official code] Using different textures or contrasting, but complimentary, materials and variation in transparency. [image omitted; see the official code] Use of windows and/or openings. [image omitted; see the official code] Use of landscaping and varying materials. Appendix Illuminance Requirements for Parking Lots These requirements include exterior lighting practices for the reasonably safe movement of vehicular and pedestrian traffic in parking facilities, the enhancing of personal security and the deterring of vandalism, while conserving energy and minimizing maintenance. They provide minimum guidelines, but are subject to variations based upon sound engineering judgment. Retailers, especially big-box stores, usually prefer higher levels of illuminance than specified herein, to attract customers or to more strongly address perceptions of personal security needs. Generally speaking, parking lots and parking structures have vehicular speeds that are much lower than roadways. More importantly, the primary purpose of the lighting here is to benefit the pedestrian. It is intended that a driver (or pedestrian) looking at the brightest spot in the field of view will also be able to detect an object in the dark areas within the field of view. This detection can only occur if the maximum-to-minimum illuminance is limited to a range that the human eye can see. Table 1: Recommended Maintained Illuminance Values for Parking Lots Basic 1 | Enhanced Security 2 Minimum Horizontal Illuminance 3 | lux 4 | 2 | 5 fc 2 | 0.2 | 0.5 Uniformity Ratio, Maximum to Minimum 6 | 20:1 | 15:1 Minimum Vertical Illuminance 7 | Lux 8 | 1 | 2.5 fc 5 | 0.1 | 0.25 Basic lighting requirements tend to be similar for most land uses. Typical or average security needs are equally as great in a parking lot serving an apartment building or a regional shopping center. In fact, the higher the pedestrian activity level, the lower the likely security problem. However, greater pedestrian activity usually equates to greater conflict with vehicles. Because these conditions tend to counterbalance, no difference in the basic level of illuminance appears warranted among various land uses. However, customer attraction can be a reason to provide illuminance higher than the basic illuminance level given in Table 1. When higher light levels are used, retailers should give careful consideration to the safety consequences of drivers exiting the parking facility directly onto adjacent streets with lower lighting levels. HARDY PLANTS FOR USE IN CORRIDOR LANDSCAPING PROJECTS Recommended by: University of Wyoming College of Agriculture Cooperative Extension Service Natrona County Casper, Wyoming Evergreen Trees Abies Concolor - Concolor Fir (white fir) Juniperus Scopulorum - Rocky Mountain Juniper, many varieties Juniperus Virginiana - Eastern Red Cedar, many varieties Pinus Aristata - Bristlecone Pine Pinus Cembroides Edulis - Pinyon Pine Pinus Ponderosa - Ponderosa Pine Deciduous Trees Acer ginnala - Amur Maple (understory or screening use) Acer negundo - Boxelder (sensation variety only) Aesculus glabra - Ohio buckeye Catalpa specious - Northern or Western catalpa Celtis occidentalis - Hackberry Crataegus sp. - Hawthorne - many varieties Gleditsia triacanthos inermis - Honey locust, several varieties Gymnociadus dioicus - Kentucky coffee tree Quercus gambelii - Gambel oak (scrub oak) Quercus macrocarpa - Bur oak Rhus typhina - Staghorn sumac Robinia neomexicana - New Mexico locust Robinia pseudoacacia - Black locust Tilia Americana - American linden Tilia cordata 'Greenspire' - Greenspire linden Tilia tomentosa - Silver linden Shrubs Caryoptevis x Clandonensis - Blue Mist Spirea Cercocarpus Ledifolius - Motintain Mahogany Cotoneaster Apiculatus - Cranberry Cotoneaster Holodiscus Dumosus - Rock Spiraea Juniperus Chinensis - Chinese Juniper Juniperus Communis - Common Juniper Juniperus Horizontalis - Spreading Juniper Rhamnus Cathartica - Common Buckthorn Rosa Rugosa - Rugosa rose, Ramanas Rose Symphoricarpos Alba - Snowberry Perennials Achillea sp. - Yarrow Asclepias Tuberosa - Butterfly Weed Callirhoe Involucrata - Wine Cup Centranthus Ruber - Valerian Eviogonum Umbellatum - Sulfur Flower Gaillardia x grandiflora - Blanket Flower Hemerocallis sp. - Daylily Nepeta x faassenii - Catmint Oenothera Missouriensis - Evening Primrose Perovskia atriplicifolia - Russian Sage Salvia - Sage Sedum sp. - Stonecrop Tanacetum Densum - Partridge Feather Vines Lonicera - Honeysuckle Vine Polygonum Aubertii - Silver Lace Vine Groundcovers Antennaria Dioica - Pussytoes Cerastium Tomentosum - Snow-in-Summer Polygonum Affine - Fleece Flower Sedum - Stonecrop Sempervivum sp. - Hens and Chicks Thymus Pseudolanuginosus - Woolly Thyme Veronica Pectinata - Woolly Speedwell
(Ord. 21-08 § 1 (part), 2008) (Ord. No. 3-09, §§ 3—5, 2-17-2009; Ord. No. 25-09, § 1, 12-15-2009; Ord. No. 7-11, § 1, 3-1-2011)
Ask a question about Casper law
Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.
