For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.10.020 — Amendments

Cheyenne Municipal Code, Cheyenne, Wyoming (Supp. No. 73: covering ordinances through No. 4662, passed March 23, 2026) · Cheyenne Municipal Code § 15.10.020

Corpus is an independent public-information project, not the official City of Cheyenne website. Stable reference: corpuslaw.us/code/9a9c78ba-76a0-4f78-afbc-cb50d130c25c

15.10.020 - Amendments.

The International Residential Code adopted in Section 15.10.010 above is amended as follows: A. Section R101.1. Insert: The City of Cheyenne; for [NAME OF JURISDICTION]. B. Section R105.2, Work exempt from permit, Subsection 2. under the heading "Building" is amended to read as follows: 2. Fences not over 6 feet high. C. Section R105.5 is deleted and re-created to read as follows: Every permit issued shall expire and become invalid one year after the date of issuance. The chief building official is authorized to grant one 180-day renewal permit, for a non-expired permit, subject to written request by the permit holder. If approved, a renewal permit is subject to an additional permit fee based upon fifteen percent (15%) of the original permit valuation. D. Section R106.2 is amended by the addition of a second paragraph to read as follows: Drainage plans shall be submitted for all building permit applications for all new residential construction. Drainage plans shall be prepared by a Wyoming Licensed Professional Engineer (P.E.) or Professional Land Surveyor (P.L.S.). Drainage plans shall indicate, with drainage arrows, the drainage patterns for the site. Drainage away from the structure shall be in conformance with this code. Site grading and drainage shall conform to the approved grading or drainage plan for the subdivision where the site is located. All drainage easements on the lot shall be shown on the drainage plan. All FEMA-regulated floodplain or city-delineated special flood hazard area boundaries shall also be shown on the drainage plan. No variation from the approved grading or drainage plan for the subdivision where the site is located will be granted an exception, except by written authorization from the city engineer or his designated representative. E. Section R108.2. Fees shall be as indicated in Section 15.08.030 of the Cheyenne City Code. F. Section R108.2.1 is created to read as follows: Reinspections. A reinspection fee may be assessed for each inspection or reinspection when such portion of the work for which inspection is called is not complete or when corrections called for are not made. This section is not to be interpreted as requiring reinspection fees the first time a job is rejected for failure to comply with the requirements of this code, but as controlling the practice of calling for inspections before the job is ready for such inspection or reinspection. Reinspection fees may be assessed when the inspection record card is not posted or otherwise available on the work site, the approved plans are not readily available to the inspector, for failure to provide access on the date for which inspection is requested, or for deviating from plans requiring the approval of the building official. To obtain a reinspection, the applicant shall file an application therefore in writing on a form furnished for that purpose and pay the reinspection fee in accordance with Section 15.08.030. In instances where reinspection fees have been assessed, no additional inspection of the work will be performed until the required fees have been paid. G. Section R108.5 is deleted and re-created to read as follows: Fee refunds shall be as specified in Section 15.08.040 of the Cheyenne City Code. H. Section R108.6 is amended to read as follows: Work commencing before permit issuance. Any person who commences any work on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the necessary permits shall be subject to an investigation fee. The investigation fee shall be in an amount equal to the permit fee. I. Section R110.3 is amended to read as follows: 1. Delete the first paragraph and re-create to read as follows: After the chief building official inspects the building or structure and finds no violations of the provisions of this code or other laws that are enforced by the Department of Building Safety and has received certification from a Wyoming Licensed Professional Engineer (P.E.) or Professional Land Surveyor (P.L.S.) that the approved plot plan conforms with this code and the approved grading or drainage plan of the subdivision where the site is located, with his or her original seal and signature affixed, the chief building official shall issue a certificate of occupancy which shall contain the following: (Remainder of section unchanged). J. Section R112 is deleted in its entirety and re-created to read as follows: Appeals shall be made to the board of appeals as prescribed by Section 15.04.020 of the Cheyenne City Code. K. Section R113.4 is amended by the adoption of a final sentence to read as follows: Penalties shall be as specified in Section 1.24.010 of the Cheyenne City Code. L. Section R301.2 and Table R301.2(1) Climatic and Geographic Design Criteria, is amended to read as follows: GROUND SNOW LOAD: 30# psf; WIND SPEED: 115 (Vult) mph; TOPOGRAPHIC EFFECTS: NO; SPECIAL WIND REGION: NO; WIND-BORNE DEBRIS ZONE: NO; SEISMIC DESIGN CATEGORY: B; WEATHERING: Severe; FROST LINE DEPTH: 36 inches (for footings and foundations); TERMITE: Slight to Moderate; WINTER DESIGN TEMP: -1 degree Fahrenheit; ICE BARRIER UNDER LAYMENT REQUIRED: YES; FLOOD HAZARDS: FIRM effective date, September 30, 1977; Map effective date: January 17, 2007; panel numbers and dates of the currently effective FIRMS: 56021C1083F | 01/17/2007 56021C1079F | 01/17/2007 56021C1078F | 01/17/2007 56021C1111F | 01/17/2007 56021C1091F | 01/17/2007 56021C1087F | 01/17/2007 56021C1086F | 01/17/2007 56021C1118F | 01/17/2007 56021C1114F | 01/17/2007 56021C1113F | 01/17/2007 56021C1089F | 01/17/2007 56021C1376F | 01/17/2007 56021C1352F | 01/17/2007 56021C1351F | 01/17/2007 56021C1335F | 01/17/2007 56021C1353F | 01/17/2007 56021C1092F_ REV_04_14_11 | 04/14/2011 56021C1113F_ REV_04_14_11 | 04/14/2011 56021C1094F_ REV_04_14_11 | 04/14/2011 56021C1093F_ REV_04_14_11 | 04/14/2011 56021C1093F_ REV_09_27_12 | 09/27/2012 56021C1089F_ REV_09_27_12 | 09/27/2012 56021C1356F_ REV_09_27_12 | 09/27/2012 56021C1352F_ REV_09_27_12 | 09/27/2012; AIR FREEZING INDEX: 2,000; MEAN ANNUAL TEMP: 45 degrees Fahrenheit. M. Section R302.13 is amended by creating exception 6 for the fire protection of floors for dwellings where future work in the basement is planned by homeowner as follows: 6. Floor assemblies to accommodate mechanical, plumbing or electrical work for future basement finishes by the homeowner. N. Section R325.3 is deleted in its entirety. O. Section R317.5 is deleted in its entirety. P. Section R318.1 is amended by deleting exception Number 1. Q. Section R309 is created to read as follows: R309 The provisions contained in this section shall not be mandatory but shall be optional at the discretion of the owner or contractor of the structure. In the event the owner or contractor wishes to provide an automatic fire sprinkler system, it shall comply with this section. Other provisions contained in Section R309 remain unchanged. R. Section R908.4 is amended by deleting item Number 3 and re-creating item Number 3 to read as follows: 3. Where the existing roof has one or more applications of asphalt shingles as the City of Cheyenne is considered to be in an area subject to moderate hail exposure. S. Part IV Energy Conservation, Chapter 11 Energy Efficiency is deleted and re-created to read as follows: CHAPTER 11 ENERGY EFFICIENCY Energy efficiency shall be as prescribed by the 2018 Edition of the International Energy Conservation Code as adopted in City Code Chapter 15.26. T. Section G2406.2, Exceptions 3 and 4, are deleted in their entirety and re-created to read as follows: Unvented fuel burning equipment shall not be installed, used, maintained, or permitted to exist in any building. U. Section G2413.7 is deleted and re-created to read as follows: Maximum gas delivery pressure: The maximum gas delivery pressure for one and two family dwellings shall be six (6) inches water column. V. Sections G2417.4.1 and G2417.2 are deleted and re-created to read as follows: The test pressure to be used shall be not less than 10 PSI for a 15-minute duration. W. Section P2503.5.1. The first sentence is amended to read as follows: P2503.1 Rough Plumbing. DWV systems shall be tested on completion of the rough piping installation by water or by air with no evidence of leakage. X. Section P2603.5.1. Insert 36 inches for [NUMBER] in both locations. Y. Section P3008 is deleted in its entirety. Z. Section P3103.1. Change 6 inches to 12 inches in both locations. AA. Delete all the electrical chapters from the International Residential Code to include chapters: 34, 35, 36, 37, 38, 39 and 40. All electrical work shall comply with the currently adopted NFPA 70 (National Electrical Code). BB. Section BA101.3, Zoning, is created to read as follows: All manufactured housing units placed within the city shall comply with the provisions of Section 5.8.2.h of the Cheyenne Unified Development Code.

(Ord. No. 4613, § 3, 2-24-25; Ord. No. 4485, § 3, 1-9-23; Ord. No. 4254, § 4, 12-20-18; Ord. No. 4140, § 4, 6-27-16; Ord. No. 3998, § 4, 9-9-13; Ord. No. 3864, § 4, 6-22-09; Ord. 3681 § 2, 2005; Ord. 3621 § 3 (part), 2005)

Ask a question about Cheyenne law

Corpus searches the Cheyenne sections it holds and shows the ones that match, with their citations. Free, no sign-in.