Sec. 10-44. - Standards for manufactured homes.
(a) [Elevation required.] Must be elevated on a permanent foundation to have its lowest floor elevated to no lower than one (1) foot above the base flood elevation. (b) Minimum blocking standards. (1) Pier foundations shall be installed directly under the main frame (or chassis) of the manufactured home. The piers shall not be further apart than ten (10) feet on centers and the main frame, front or back, shall not extend further than five (5) feet beyond the center line of the end of the piers. (2) All grass and organic material shall be removed and the pier foundation placed on stable soil. The pier foundation shall be a sixteen-inch by sixteen-inch by four-inch solid concrete pad, precast or poured in place or equivalent. (3) When concrete piers are used, they must be constructed of regular eight-inch by eight-inch by sixteen- inch concrete blocks, open cells, solid or equivalent (with open cells vertical), placed above the foundation. A two-inch by eight-inch by sixteen-inch pressure-treated wood plate or equivalent shall be placed on top of the pier with shims fitted and driven tight between the wood plate and the main frame. Shims shall not occupy more than one (1) inch of vertical space. Single tiered block piers shall be installed perpendicular to the main I-beam. Steel piers or other pier devices when approved by the insurance commissioner may be used in lieu of concrete. (Combination of blocks and steel piers prohibited). (4) All piers over forty (40) inches in height shall be double-tiered with blocks interlocked and capped with a four-inch by sixteen-inch by sixteen-inch solid concrete blocks or equivalent, and cushioned with wood shims or pressure-treated plate. (c) Minimum anchoring standards. (1) Ground anchors shall be aligned close to the end of piers, but not in exact center that will interfere with frame ties. Also, they shall be situated immediately below the outer wall to accommodate over- the-top ties as well as frame ties. (2) Auger-type anchors shall be at least four (4) feet in length, have a minimum diameter of six (6) inches (arrowheads eight (8) inches) and be sunk their full depth. Steel rods shall be at least five-eighths-inch diameter, have a forged or welded eye at top, or have a yoke-type fastening and tensioning device or a threaded connector and tensioning device. Anchors shall be capable of withstanding four thousand seven hundred fifty (4,750) pounds of pull (in a vertical or diagonal direction) without failure. (3) Anchors to reinforced concrete slabs must be of strength comparable to that presented above. (4) Other anchors which are capable of withstanding four thousand seven hundred fifty (4,750) pounds of pull without failure may be approved by the mobile home division of the state fire marshal's office as equivalent to above specifications. (5) All anchors previously approved by this office are void and must be reapproved by the mobile home division or the state fire marshal's office prior to their use in this state. (d) Tie-downs. (1) All manufactured homes shall have tie-downs with provisions for distributing the load of these tiedowns and provisions for the attachment to the ground anchors so as to resist wind overturning and sliding as imposed by the respective design loads of this chapter. (2) Each tie-down shall be designed to resist an allowable working load equal to or exceeding three thousand one hundred fifty (3,150) pounds and shall be capable of withstanding a fifty (50) percent overload without failure. (3) Unless the tie-down system is designed by a registered professional engineer or architect, tiedowns shall be placed as follows: Non-hurricane zones: Not more than twenty-four (24) feet on centers beginning from the front wall (first stud and/or first cross member). Not more than six (6) feet open-end spacing shall be provided at the rear wall of the manufactured home unless additional tie-downs are installed. (4) Provisions for diagonal ties between ground anchors and the manufactured homes shall be made in conjunction with each vertical tie-down. (5) Minimum specifications for tie-down materials shall be: 1¼ × .035 cold rolled, heat treated, hot dipped galvanized steel strapping. Said strapping shall be manufactured to conform to Federal Specifications QQ-S-781F, Type 1, Class B, Grade 1. Breaking strength must be a minimum of four thousand seven hundred fifty (4,750) pounds. Hot dipped, zinc coating shall be a minimum of 0.30 ounces per square foot of surface. Any materials (including cable) other than those specified above must be equal to or exceed said federal specification as regards strength and weather resistance. (6) The support and anchoring systems of all manufactured homes that bear the HUD label shall be designed by a registered professional engineer or architect and meet the requirements of Part 280.306 of the National Mobile Home Construction and Safety Standards. The manufacturer shall provide complete tie-down instructions with each manufactured home.
(Ord. No. 3963, § 8D-F, 12-7-93; Ord. No. 4569, 1-17-23)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.