Amendments to the 2024 International Residential Code for One- and Two-Family Dwellings.
Metropolitan Code of Nashville and Davidson County § 16.08.014
in effect16.08.014 - Amendments to the 2024 International Residential Code for One- and Two-Family Dwellings.
The following amendments, deletions, or additions to the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings are adopted by reference, as fully as though copied into such Dwelling Code, and thereby made a part of the Dwelling Code.
A. Section R101.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section R101.1 and substituting the following:
R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings of Metro Nashville, Tennessee, and shall be cited as such and will be referred to herein as "this code".
B. Sections R102.1 through R106.5 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings are hereby amended by deleting Sections R102.1 through R106.5 in their entirety.
C. Section R107.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting R107.1 Section and substituting the following:
R107.1 General. The building official is authorized to issue a permit for temporary structures and temporary uses. Such permits shall be limited as to time of service but shall not be permitted for more than 90 days. The building official is authorized to grant extensions for demonstrated cause.
D. Sections R108.1 through R114.4 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Sections R108.1 through 114.4 in their entirety.
E. Section R202 of the 2024 Edition of the International Residential Code for One-and Two-Family Dwellings is hereby amended by adding the following new definitions to Section R202.
BED AND BREAKFAST HOMESTAY—means a private home, inn or other unique residential facility located in a structure of historical significance as defined in Tennessee Code Annotated Section 68-14-503(3) offering bed and breakfast accommodations and one (1) daily meal and having less than four (4) guest rooms furnished for pay, with guest staying not more than fourteen (14) days, and where the innkeeper resides on the premises or property, or immediately adjacent to it. Guest rooms shall be established and maintained distinct and separate from the innkeeper's quarters.
BOARD—shall mean the Metropolitan Board of Fire and Building Code Appeals.
BUILDING OFFICIAL—shall mean the Director of the Metropolitan Department of Codes Administration.
DIRECTOR—shall mean the Director of the Metropolitan Department of Codes Administration, his deputy or duly authorized representative.
NORMAL MAINTENANCE REPAIRS—shall be defined as repairs to an existing building or structure, including but not limited to exterior and interior painting, papering, glazing of windows and doors, floor finishing, minor repairs to chimneys, stairs, porches, underpinning, and repairs to an existing roof.
TEMPORARY—shall mean not more than 90 calendar days.
F. Table R301.2 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Table R301.2 and substituting the following:
Ground Snow Load (lbs.) | 10
Wind Design | Speed (mph) | 115
Topographic effects | No
Special Wind Region | No
Windborne Debris Zone | No
Seismic Design Category | C
Subject to Damage From: | Weathering | Severe
Frost line depth (inches) | 12"
Termite | Heavy
Winter Design Temp (Degrees) | 14° F
Ice Barrier Underlayment Required | No
Flood Hazards | In accordance with adopted Storm Water ordinance
Air Freezing Index | 366
Mean Annual Temp | 59° F
Manual J Design Criteria Elevation (feet) | 640
Latitude (Degrees North) | 35
Winter Heating | 14
Summer Cooling | 94
Altitude Correction Factor | *
Indoor Design Temperature | 70
Design Temperature Cooling | 75
Heating Temperature Difference | *
Cooling Temperature Difference | *
Wind Velocity Cooling | *
Coincident Wet Bulb | 74
Daily Range | M
Winter Humidity | *
Summer Humidity | *
*This value to be determined using Manual J Design criteria.
G. Section R302.13 of the 2024 Edition of the International Residential Code for One- and two-Family Dwellings is hereby amended by deleting Section R302.13 and substituting the following:
R302.13 Fire protection of floors. Floor assemblies, not required elsewhere in this code to be fire-resistance rated, shall be provided with a 1/2-inch (12.7 mm) gypsum wallboard membrane, 5/8-inch (16 mm) wood structural panel membrane, or equivalent on the underside of the floor framing member. Penetrations or openings for ducts, vents, electrical outlets, lighting, devices, luminaires, wires, speakers, drainage, piping and similar openings or penetrations shall be permitted.
Exceptions:
1. Floor assemblies located directly over a space protected by an automatic sprinkler system in accordance with Section P2904, NFPA13D, or another approved equivalent sprinkler system.
2. Floor assemblies located directly over a crawl space not intended for storage.
3. Portions of floor assemblies can be unprotected when complying with the following:
3.1. The aggregate area of the unprotected portions shall not exceed 80 square feet per story.
3.2. Fire blocking in accordance with Section R302.11.1 shall be installed along the perimeter of the unprotected portion to separate the unprotected portion from the remainder of the floor assembly.
4. Wood floor assemblies using dimension lumber or structural composite lumber equal to or greater than 2-inch by 10-inch (50.8 mm by 254 mm) nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance.
H. Sections 306.1 through 306.3.10 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Sections R306.1 through R306.3.10 in their entirety.
I. Section R308 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section R308 and substituting the following:
R308 Address Identification. All buildings and structures within Metropolitan Nashville and Davidson County shall have approved address numbers posted in accordance with following: Residences are to have their numbers at least three (3) inches in size, on a contrasting background, and in a position to be plainly visible and legible from the street or road fronting the property. The numbers may be attached to the residence or the mailbox, if the mailbox is next to the street.
J. Section R309.1 of the 2024 Edition of the International Residential Code for One-and Two-Family Dwellings is hereby amended by creating a new Section R309.1:
R309.1 Townhouse automatic fire sprinkler systems. A townhouse shall be considered a separate building with independent exterior walls and shall be separated by a two-hour fire-resistance-rated wall assembly. A townhouse shall be built according to local and statewide adopted building codes; provided, however, a fire sprinkler system shall not be required for a townhouse. For the purposes of this Code, "townhouse" means a single family dwelling unit constructed in a group of three (3) or more attached units that extends from foundation to roof, not more than three (3) stories in height, with a separate means of egress, and an open space or public way on at least two (2) sides.
K. Section R309.2 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section R309.2 in its entirety.
L. Section 310.2.2 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by adding the following new exception:
Exception 3. The interconnection and hardwiring of smoke alarms in existing areas shall not be required where the alterations or repairs do not result in the removal of interior walls or ceiling finishes exposing the structure.
M. Chapter 3 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by adding the following new section R333 HOUSE MOVING:
SECTION R333.1
Any person desiring to move any house, building, or structure shall comply with all of the provisions set forth in Section 16.28.175 of the Metropolitan Code and other provisions of this Code.
N. Section R403.1 of the 2024 Edition of the International Residential Code for One- and two-Family Dwellings is hereby amended by deleting Section R403.1 and substituting the following:
R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings, wood foundations, or other approved structural systems which shall be of sufficient design to accommodate all loads according to Section R301 and to transmit the resulting loads to the soil within the limitations as determined from the character of the soil. Footings shall be supported on undisturbed natural soils or engineered fill. All concrete footing shall have minimum bottom reinforcement. Minimum reinforcement shall be 2-#4's continuous and shall be located a minimum of 3 inches clear from the bottom and side of the footing. Concrete footings shall be designed and constructed in accordance with the provisions of Section R403 or in accordance with ACI 332.
O. Chapter 11 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by:
1. Deleting Table N1102.1.2 Maximum Assembly U-Factors and Fenestration Requirements, and Table 1102.1.3 Insulation Minimum R-values and Fenestration Requirements by Component in their entirety and replacing them with Table N1102.1 Insulation and Fenestration Requirements by Component and Table N1102.1.2 Equivalent U-Factors from the 2009 International Residential Code.
2. Deleting Section N1102.5.1.2 Air Leakage Testing in its entirety and replacing it with Section 1102.4.2.1 Testing Option and Section N1102.4.2.2 Visual Inspection from the 2009 International Residential Code.
P. Section N1103.5.2 Hot Water Pipe Insulation is hereby deleted in its entirety and substituting the following:
Section N1103.5.2 Hot Water Pipe Insulation. Insulation for service hot water piping shall comply with Table N1103.5.2 and shall be applied to the following:
1. Piping ¾ inch and larger in nominal diameter, unless located in a conditioned space.
2. Piping located outside the conditioned space.
3. Piping from the water heater to a distribution manifold.
4. Piping under a floor slab, unless sleeved with a minimum of one pipe size larger than the pipe being served.
5. Buried piping, unless sleeved with a minimum of one pipe size larger than the pipe being served.
6. Supply and return piping in circulating hot water systems.
Exception: Cold water returns in demand recirculation water systems.
(Ord. BL2025-898 § 1, 2025; Ord. BL2024-182 § 3, 2024; Ord. BL2023-2009 § 1, 2023; Ord. BL2020-458 § 1, 2020; Ord. BL2015-1145 § 8, 2015; Ord. BL2010-613 § 1, 2010; Ord. BL2007-1373 § 2, 2007; Ord. BL2001-703 § 2, 2001; Ord. 98-1445 §§ 45—47, 1998; Ord. 96-562 §§ 9—25, 1996; Ord. 95-1542 § 3, 1995; Ord. 95-1487 §§ 20—27, 1995; Ord. 92-118 § 4, 1992)
Source: Metropolitan Government of Nashville and Davidson County, Metropolitan Code and Charter (Municode Library, library.municode.com)URL: https://library.municode.com/tn/metro_government_of_nashville_and_davidson_county/codes/code_of_ordinances?nodeId=CD_TIT16BUCO_CH16.08BUCO_16.08.014AM2024INRECOOMIDWFetched: 10/28/2026