§ 16-87 — Adding or replacing equipment in attics

Code of Ordinances of the City of Pasadena, Texas (Supp. No. 33, Update 2: codified through Ordinance No. 2026-143, enacted September 1, 2026) · Pasadena City Code § 16-87

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/0812e68a-caa2-4227-80cb-daa2ed95eedf

Sec. 16-87. - Adding or replacing equipment in attics.

All heating or cooling equipment installed in attics shall be installed a maximum of twenty (20) feet from approved attic access, and shall have a minimum height of thirty-six (36) inches of attic space with sufficient openings communicating to the outside for required combustion air. A light shall be installed a maximum of six (6) feet in front of the service side of the unit being installed, and controlled by a switch at the attic access opening. All equipment shall have a separate means of disconnect, adjacent to and within sight of the equipment, for service or replacement. All 110v outlet shall be installed next to service side of equipment. All gas furnace flue pipe shall be installed as per Uniform Mechanical Code, with a maximum increase of one (1) size. All new flue pipe shall have matching new cap, collar, and flashing. Deteriorating roof jacks or flashings shall be replaced.

(Ord. No. 17-009, § 1(Exh. A), 1-17-17)