15.33.140 - Non-proximate blasting permit requirements.
A. Blasting permit. A blasting permit application will be considered by the fire chief and director of building and fire safety or their designee to be complete and ready for review once the application includes:
1. A completed application form provided by the City of Henderson;
2. Site maps and drawings;
3. Blasting plan;
4. Seismograph monitoring plan;
5. Traffic and access control plan;
6. Notification plan;
7. Proof of bonding or insurance;
8. Utility acknowledgement (when applicable).
Six copies of the entire application packet are required for all blasting permit applications.
B. Application form. An application form approved by the fire chief and building and fire safety director shall be completed and submitted for each blasting permit.
C. Site maps and drawings. An aerial site map with measured distances shall be submitted and shall:
1. Show the perimeter of the blast area;
2. Identify the locations of all buildings, utilities, and gas transmission pipelines located within 1,000 feet of the blast site;
3. Measure the distance(s) to the closest building(s) from the nearest blast hole.
The blast sites shall be superimposed upon the approved engineered grading plan and shall include information designated in subsections (c)(1) and (c)(2) of this section.
D. Blasting plan. Blast plans shall be provided for all applications within the notification distance as shown in Figure 2. Information deemed proprietary in nature by the applicant shall be clearly and distinctly identified as such. The city will maintain any proprietary information submitted in accordance with the Nevada Revised Statutes. The plan must include:
1. The location where the blast(s) will occur and the nearest building designated on a map or drawing using either of the following two methods:
a. An engineered scaled drawing with the nearest buildings located on this drawing; or
b. Show the blast site on a generic drawing/map by providing measured distances from the perimeter of the blast site to the nearest buildings;
2. The measured distance to the nearest building shall be provided;
3. The approximate total amount of material to be blasted (cubic yards);
4. The incremental volumes, per blast, of material to be blasted;
5. The types and packaging of explosive materials to be used;
6. The drill hole diameters, depths, patterns, sub drilling depths and drill hole orientation to be used;
7. A description of the initiation system, the incremental delay times, and the location of the primers in the explosive column;
8. A description of the stemming depths and stemming material for the various estimated depths of drill holes to be blasted;
9. The blast design shall provide either:
a. The maximum pounds per delay to be detonated within eight milliseconds based on the distance to the nearest building; or
b. The scaled distance factor (SD) that they will stay above for the blasts;
10. A description of the fly rock control procedures and equipment to be used;
11. A description of the blast warning sound system and equipment to be used;
12. The scheduled start date and finish date of blasting operations;
13. Additional information as requested.
E. Seismograph monitoring plan. A monitoring plan will be submitted to identify the name and address of an independent vibration monitoring company and describe plans for seismograph use, monitoring and reporting. A seismograph monitoring plan will include:
1. The number and general locations of seismographs to be used during monitoring identified on the site map;
2. The plan will include a sufficient number of seismographs strategically located within the surrounding neighborhoods to measure the influence of distance and direction on ground vibrations and airblast;
3. The name of the company supplying and operating seismographs and responsible for preparing the seismograph report;
4. The manufacturer and model of seismographs employed;
5. Seismograph monitoring shall comply with the International Society of Explosives Engineers (ISEE) Field Practice Guidelines for blasting seismographs.
F. Traffic and access control plan. A traffic and access control plan shall include warning signage, flagging, temporary road closures, and detour routes for blasting operations. Permit areas that are secured from entry by the general public are exempt from this equipment.
During the loading and detonation of a blast hole, signs shall be conspicuously placed reading "Blasting Area" along the edge of any blasting area. Access within the blasting area shall be controlled to prevent presence of unauthorized persons during blasting and until an authorized representative of the operator has reasonably determined that no unusual hazards, such as undetonated charges, exist, and access to and travel within the blasting area can be safely resumed.
G. Notification plan. The notification plan shall consist of the following: (i) blasting notification mailing, (ii) neighborhood meeting.
1. The director of building and fire safety and the fire chief are authorized in their joint discretion to:
a. Allow one blasting notification mailing and/or neighborhood meeting for a project that involves multiple permits such as, but not limited to, projects requiring permit renewals; geographic proximity of proposed blast areas in relation to other development; and master planned communities;
b. Allow one blasting notification mailing and/or neighborhood meeting for multiple projects that involve multiple permits such as, but not limited to, projects subject to a master development agreement; contiguous projects; and master homeowner associations;
c. Require additional blasting notification mailing(s) and/or neighborhood meeting(s) if the scope of the project substantially changes or otherwise warrants additional information sharing with the public such as, but not limited to, substantial acreage added to permit area; or change to blasting plan;
d. Not require blasting notification mailing and/or a neighborhood meeting for permit applications that fall within the scope and notification distance requirements of existing permits by the same blasting contractor.
2. Blasting notification mailing. A blasting notification mailing shall be sent to all property owners, and homeowner associations, with a copy provided to the City of Henderson departments of building and fire safety, and neighborhood services, within the scaled notification distance from the perimeter of the assessor's parcel numbers or applicant's designated blast site(s) upon which the blasting permit is requested no less than seven days and no greater than 21 days prior to the start of blasting operations. When fewer than five different property owners are within the notification distance, the applicant may propose a custom plan for informing these owners pursuant to this section. The fire chief and building and fire safety director may accept or modify this plan.
The notification distance for a blasting notification mailing shall be based on Figure 2. The distance from the perimeter of the assessors parcel number containing the closest blast site for notifying property owners is the point where the weight intersects the line on the chart. The weight is based on the applicant's statement stating the maximum anticipated pounds of explosives in any single delay.
FIGURE 2
[image omitted; see the official code]
Figure 2 is based on the following equation: D (ft) = 210 * W ½ (lbs) where D is the scaled notification distance and W is the maximum charge weight per eight ms delay.
Upon request, the City of Henderson will provide a mailing list for all residences within the scaled notification distance from the perimeter of the assessor's parcels upon which the blasting permit is requested. A fee shall be charged to recover the cost of providing this service.
The applicant may request to have the city prepare and process the mailing for the neighborhood meeting and shall charge a fee to recover the cost of providing this service.
The blasting notification mailing shall have a return address identifying the applicant. The contents of the notice shall include, but are not limited to, the following:
a. Why the blasting is necessary;
b. Name of blasting company;
c. When the blasting will occur, i.e., date range and approximate times of blasting;
d. Where the blasting will be conducted. A map shall be provided;
e. How to contact the blasting company;
f. Date, time, location of the required neighborhood meeting.
When no blasting occurs for a period of 30 or more days, a new blasting notification mailing shall be sent. The notice shall include subsections (2)(a) through (2)(e) of this section.
3. Neighborhood meeting. The location of the neighborhood meetings are subject to the approval of the fire chief and building and fire safety director.
A neighborhood meeting will be conducted prior to the issuance of a non-proximate blasting permit by representatives of the blasting company, the developer, and the vibration consultants implementing the monitoring program.
Information provided to neighborhood residents will include, but is not limited to:
a. A general description of the blasting activities, including an explanation of the drilling and blasting process;
b. The anticipated duration of the blasting;
c. An anticipated schedule of blasts, including estimated dates and times of blasting;
d. The qualifications of the blasters;
e. The warning signals for blasting and the all clear signal;
f. Measures to be taken for the control of ground vibrations, air blast, fly rock, fumes and dust;
g. Contact information for submitting questions or complaints;
h. Insurance carrier contact information for submitting claims;
i. A description of the vibration monitoring process.
H. Proof of insurance.
1. General. A valid certificate of insurance shall be submitted with each application when applying for a permit to conduct blasting.
2. Certificate information required. The certificate shall be issued by an insurance company authorized to transact business in the State of Nevada, or be named on the list of authorized insurers maintained by the Nevada Department of Business and Industry, Division of Insurance. The following information shall be identified:
a. The contractor shall be named as the insured. If the insurance is provided by an individual, company or partnerships other than the contractor, the contractor shall be named as an additional insured;
b. The City of Henderson Municipal Corporation, its officers, agents, employees and volunteers shall be named as additional insured and certificate holder;
c. Commercial general liability limits, including contractual liability, in the minimum amount of $5,000,000.00, per occurrence.
I. Additional insurance. Greater liability insurance amounts may be required under circumstances where the blasting activity is deemed by the fire chief and building and fire safety director to present unusual hazards.
J. Indemnification. Each permit issued under the authority of this chapter shall contain the following indemnification provision:
The permittee hereby fully indemnifies, holds harmless and agrees to defend the City of Henderson, its agents, officers and employees from any and all claims, expenses, losses, liability, actions, suits or demands, including legal defense costs thereof, of whatever nature, arising out of or connected with this blasting permit.
K. Utility notification. Utilities within 300 feet of the blast site shall be notified as follows:
1. Utility service provider shall acknowledge the use of explosives by providing a signature from an authorized person on a form provided by the City of Henderson or written permission on utility company letterhead.
Exception: alternate methods of notification as acceptable to the utility and filed with the building and fire safety department.
2. The blasting contractor shall provide a minimum of 24 hours' notice to the utility in advance of the initial blast.
(Ord. 2416, §§ 1—2, 2005; Ord. 2388, § 3 (part), 2005)