§ 25-65 — Single family residential 4
Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 25-65
Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/125a3e16-f279-4f23-9f0c-56ab93760236
Sec. 25-65. - Single family residential 4.
a. Purpose. The purpose of the single family residential 4 (SFR-4) district is to provide lands for residential neighborhoods that accommodate small- and medium-lot single-family detached homes, duplexes, and limited scale townhouses. The district is intended to support a medium-density residential environment and may include compatible public, civic, and institutional uses. b. Use standards. Allowed uses and use-specific standards for principal, accessory, and temporary uses are established in article V, use regulations. c. Intensity and dimensional standards. All development in the SFR-4 district shall comply with the standards in table IV-17: SFR-4 intensity and dimensional standards. Table IV-17: SFR-4 Intensity and Dimensional Standards Standard [1] | Duplex units on separate lots | Townhouse | All other uses Density (max) | 6 du/acre | 15 du/acre | 6 du/acre (residential uses) Lot area (min) | Lot with front vehicular access: 7,500 sf | None | Lot with front vehicular access: 7,500 sf Lot with rear vehicular access only: 5,000 sf | Lot with rear vehicular access only: 5,000 sf A | Lot width (min) | 30 ft | 16 ft [2] | 50 ft B | Front setback (min) | 15 ft [3] | 15 ft [3] | 15 ft [3] C | Side setback (min) | 5 ft [4] | 0 ft [4] | 5 ft [4] D | Rear setback (min) | 20 ft | 20 ft | 20 ft E | Building height (max) | 35 ft | 35 ft | 35 ft Notes: [1] max = maximum; min = minimum; du = dwelling units; ft = feet; sf = square feet [2] No townhouse unit shall be less than one-third as wide as it is deep. [3] The minimum front setback may be decreased to the average alignment of existing buildings within 100 feet on either side of subject building and within the same block if such alignment is less than 15 feet. A street-facing garage shall be set back at least 20 feet from the front lot line. [4] Does not apply on side lot lines where dwelling units are attached. There is no minimum side setback for townhouses, except a minimum side setback of seven feet is required at each end of a row of townhouses. [image omitted; see the official code] d. Additional development standards. The following building material requirements apply to all development in the SFR-4 district. 1. Primary materials. Primary material changes may occur only at building corners where a maximum of one of the façades faces a street. The following materials are required for not less than seventy-five (75) per cent of the building wall surface area on each façade: i. Brick masonry; ii. Natural stone (or synthetic equivalent), such as limestone, granite, and marble; iii. Cementitious siding, provided no single panel is larger than three (3) feet by three (3) feet; iv. Glass curtain wall; and v. For detached building types only, vinyl shakes or singles, and vinyl clapboard (with a minimum thickness of 0.044 inches). 2. Accent materials. The following materials may make up twenty-five (25) per cent of the building wall surface area on each façade: i. Pre-cast masonry (for trim and cornice elements only); ii. Gypsum reinforced fiber concrete—GFRC (for trim elements only); iii. EIFS, only for trim; iv. Metal (for beams, lintels, trim elements, and ornamentation); v. Stucco (panels with cementitious finish, not tiles or external insulation finishing system—EIFS); vi. Split-faced block (only for piers, foundation walls and chimneys); and vii. For detached building types only: (a) Vinyl shakes or shingles; and (b) Vinyl (only trim elements). 3. Foundation and crawlspace materials. The following materials shall cover exposed foundations and open crawlspaces on each façade, and shall meet minimum ventilation requirements of the building code. i. Brick and tile masonry; ii. Natural stone; iii. Split-faced block; and iv. Formed concrete (painted or stained). 4. Alternative materials. Alternative building materials not listed in subsections 1. through 3. above may be approved by the director of planning if the director determines the alternative building materials are equivalent or better than the listed materials. The use of regionally-available materials is preferred. e. References to other standards. Development in the SFR-4 district shall comply with all applicable standards of this zoning ordinance and the subdivision regulations, including but not limited to the standards referenced in table IV-18: cross-references to other standards. Table IV-18: Cross-References to Other Standards Section | Standard Article VI, Division 1 | Mobility and Connectivity Standards Article VI, Division 2 | Off-Street Parking, Bicycle Parking, and Loading Standards Article VI, Division 3 | Landscape and Buffer Standards Article VI, Division 5 | Fence and Wall Standards Article VI, Division 6 | Exterior Lighting Standards Article VI, Division 7 | Neighborhood Compatibility Standards Article VI, Division 8 | Form and Design Standards Article VI, Division 9 | Green Building Incentives Article VI, Division 10 | Signs and Billboards Subdivision Regulations
(Ord. No. 9572, § 2, 12-17-24; Ord. No. 9670, § 3, 8-19-25)
Ask a question about Tuscaloosa law
Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
