17.40.160 - Setback and Encroachment Plane Requirements and Exceptions

A. Purpose. 1. This Section provides standards for the use and minimum size of required setbacks, and for the application of encroachment planes. 2. These standards are intended to provide open areas around structures for visibility and traffic safety; access to and around structures; access to natural light, ventilation and direct sunlight; separation of incompatible land uses; and space for privacy, landscaping, and recreation. 3. The encroachment plane standards of this Section are intended to moderate the mass and scale of proposed structures within certain residential and commercial zoning districts to maintain the desired neighborhood character. B. Setback requirements. 1. All structures. a. All structures shall comply with the setback requirements of the applicable zoning districts established by Article 2 (Zoning Districts and Allowable Land Uses) or Article 3 (Specific Plans), with the requirements of this Section, and other setback requirements established by this Article and/or Article 5 (Standards for Specific Land Uses). b. Each required setback shall be maintained open and unobstructed from the ground upward, except for trees, other plant materials, and the storage of City-provided refuse containers in single-family side or rear setbacks, and except as provided by Subsection E. (Setback and encroachment plane exceptions, allowed projections) below. c. Where the provisions of this Section conflict with an adopted Specific Plan, the Specific Plan shall control. 2. Commercial and industrial districts abutting residential zoning districts. In the commercial and industrial zoning districts, except as regulated by an adopted Specific Plan in Article 3 (Specific Plans), a 15-foot side and/or rear setback shall be provided adjacent to any abutting residential zoning district. This setback requirement shall not apply along a property line that abuts a parking overlay property (PK) that is used for parking. Single-family residential projects shall meet the rear setback requirements of the RS-6 district, two units on a lot shall meet the requirements of the RM-12 district and three or more units shall meet the setback requirements for multi-family districts (City of Gardens requirements - Section 17.22.060). C. Measurement of setbacks. The following setbacks shall be measured from each exterior wall of a structure, to define a setback line parallel to the adjacent property line. Figure 4-6 shows the location of each type of setback, and the points from which they are measured. Setbacks may be otherwise regulated by an adopted Specific Plan in Article 3 (Specific Plans). Where the provisions of this Section conflict with an adopted Specific Plan, the Specific Plan shall control. 1. Front setbacks. The front setback shall be measured at a right angle from the front property line of the lot to the point on the structure nearest to the front property line excluding the front porch. a. Corner lots. The measurement shall be taken from the nearest point on the structure, excluding any porches, to the nearest point of the property line adjoining the street that is opposite the rear yard. b. Flag lots. See Section 17.40.050 (Flag Lot Development Standards). 2. Side setbacks. Side setbacks shall be measured at right angles from the nearest point on the side property line of the lot to the nearest portion of the structure, excluding any porches; establishing a setback line parallel to the side property line that extends between the front and rear yards. 3. Rear setbacks. The rear setback shall be measured at right angles from the nearest point on the rear property line of the lot to the nearest portion of the structure, establishing a setback line parallel to the rear property line. [image omitted; see the official code] Figure 4-6 - Location and measurement of setback [image omitted; see the official code] Figure 4-7 - Flag lot setbacks D. Encroachment plane requirements. Proposed structures shall comply with the following encroachment plane requirements, or as otherwise regulated by an adopted Specific Plan in Article 3 (Specific Plans), in addition to the minimum setback requirements of this Section except as otherwise provided by Subsection E. (Setback and encroachment plane exceptions, allowed projections) below. Where the provisions of this Section conflict with an adopted Specific Plan, the Specific Plan shall control. In addition to the minimum setback requirements of the applicable zoning district and as defined in Subsection C., above, a main structure within: 1. RS and RM-12 zoning districts. Principal structures within the RS and RM-12 zoning districts shall not be located within a side setback encroachment plane sloping upward and inward to the site at a 30-degree angle measured from the vertical, commencing six feet above the existing grade along the interior side property line. See Figure 4-8. [image omitted; see the official code] Figure 4-8 - Encroachment plane requirements for the RS and RM districts 2. Nonresidential structures abutting RS or RM-12 districts. Principal and accessory structures shall be located within an encroachment plane sloping upward and inward to the site at a 45-degree angle, commencing six feet above the existing grade at the property line of the abutting residential zoning district. This encroachment plane requirement shall not apply along a property line that abuts a parking overlay property (PK) that is used for parking. See Figure 4-8.1. [image omitted; see the official code] Figure 4-8.1 - Encroachment Plane Requirements for Projects Abutting RS and RM-12 Zoning Districts 3. Nonresidential structures abutting RM-16, RM-32, and RM-48 zoning districts. Principal and accessory structures shall not be located within an encroachment plane sloping upward and inward to the site at a 45-degree angle, commencing 20 feet above the existing grade at the property line of the abutting residential zoning district. This encroachment plane requirement shall not apply along a property line that abuts a parking overlay property (PK) that is used for parking. See Figure 4-9. [image omitted; see the official code] Figure 4-9 - Encroachment plane requirements for projects abutting an RM-16, RM-32, and RM-48 district 4. Multi-family projects adjacent to single-family districts. Principal and accessory structures using the City of Gardens Standards (Section 17.22.070) that adjoin an RS district along a side lot line shall provide a five-foot side yard setback and shall not be located within a side encroachment plane sloping upward and inward to the site at a 30-degree angle measured from the vertical, commencing six feet above the existing grade along the side lot line. See Figure 4-9.1. Also see encroachment exceptions in Table 4-2.1. [image omitted; see the official code] Figure 4-9.1 - Side Yard Encroachment Plane under City of Gardens E. Setback and encroachment plane exceptions, allowed projections. An attached architectural feature may extend beyond the wall of the structure and into a front, side, or rear setback, and into the encroachment plane required by Subsection D. (Encroachment plane requirements), above, in compliance with Tables 4-1 and 4-2. TABLE 4-1- ALLOWED PROJECTIONS INTO SETBACKS Projecting Feature | Allowed Projection into Setback Additions to multi-family buildings with 3 or more units built before February 14, 1989 | May project into a required interior side yard which is nonconforming as long as addition maintains existing setback and is no closer than 4 feet to a property line. Balconies (1) | Maximum depth of 10 feet into the front yard. Bay window | 24 inches into a required front, rear or corner side yard setback for a linear distance not to exceed 10 ft for any one bay, nor a total of 15 ft for all bays into each setback. Bay window (1) | No greater than 3 feet deep and 10 feet long and no higher than one story may project into the front yard. A bay window must be a minimum of 3 feet above finished grade. The maximum frequency of such bays is one bay per 15 feet of lot width measured at the front property line. Eave/roof overhang | 36 inches Fireplace or chimney (2) | 24 in. for a maximum length of 10 ft along the wall from which it projects. Fireplace or chimney (1) | 3 feet into a required yard. First story addition to main structure (2) | May project into a required interior side setback that is nonconforming as to side setback requirements; provided, that: 1. The addition maintains the existing setback of the structure to which it relates 2. The existing distance between the main structure and the side property line is a minimum of four ft; and 3. The addition does not project into a required side setback encroachment plane; and 4. The maximum length of the addition does not exceed 20 linear feet. Freestanding trellis (2) | May be located in a front or corner side yard setback; provided, that the trellis: 1. Does not occupy more than 5% of the required setback area; 2. Is nine ft or less in height; 3. Is at least 50% open on top and all sides; 4. Complies with Municipal Code Chapter 12.12 relating to the obstruction of views at intersections; and 5. Is not located over a driveway. Uncovered steps, or landings, not more than 36 in. in height (3); may project into a side yard as long as not more than 35 in. in height and there is no guard railing | 36 inches in width, for a maximum length of 10 ft. Unenclosed front porch (3) | May project into a required front setback as follows: 1. The maximum projection into the front setback shall be 10 ft, but shall be no closer than 15 ft to the front property line; 2. The width of the porch shall not exceed the width of the main structure; 3. The porch shall not exceed one story and a maximum plate height of 12 feet; and 4. The porch shall not be enclosed. Unenclosed front porch (1) | May project into a required front setback as follows: 1. The maximum projection into the front setback shall be 10 ft; 2. The porch shall not exceed one story 3. The porch shall not be enclosed. Concrete walkway or deck (2) | May project into a rear or side yard as long as not more than 6 inches in height. Notes: (1) Applies to projects subject to the City of Gardens standards of 17.22.060. (2) Applies only to projects subject to the RS or RM-12 development standards. (3) This limitation only affects the front and corner side yard setbacks. [image omitted; see the official code] Figure 4-10 - Examples of allowed projections into setbacks TABLE 4-2 - ALLOWED PROJECTIONS INTO ENCROACHMENT PLANE USING RS AND RM-12 STANDARDS Projecting Feature | Allowed Projection into Setback Eave/roof overhang | 36 inches Fireplace or chimney | 24 in. for a maximum length of 10 ft along the wall from which it projects. Dormer, gable, and/or gable end of roof structure on main structure | 36 inches Second story of main structure | An addition to an existing second story may project within the encroachment plane that is nonconforming; provided that: 1. The structure setback of the second story continues the structure setback of the second story; 2. The side setback adjacent to the main structure complies with the minimum setback of 5 feet required by the applicable zoning district; and 3. The maximum length of the addition does not exceed 16 linear feet. TABLE 4-2.1 ALLOWED PROJECTIONS INTO ENCROACHMENT PLANE FOR PROJECTS USING CITY OF GARDENS STANDARDS (17.22.070) Projecting Feature | Allowed Projection into Setback Eave/roof overhang | 36 inches Fireplace or chimney | 24 in. for a maximum length of 10 ft along the wall from which it projects. Dormer, gable, and/or gable end of roof structure on main structure | 36 inches Second story of main structure | May be within encroachment plane so long as: 1. The structure setback of the second story continues the structure setback of the first story; 2. The side setback adjacent to the main structure complies with the minimum setback required by the applicable zoning district; and 3. The structure was constructed under a Building Permit issued after June 3, 2006. F. Limitations on the use of setbacks. A required setback shall only be used in compliance with the following requirements, or as regulated by an adopted Specific Plan in Article 3 (Specific Plans). Where the provisions of this Section conflict with an adopted Specific Plan, the Specific Plan shall control. 1. Storage. No required setback shall be used for the storage of: a. Junk, inoperable vehicles, scrap, or similar material; or b. Building materials, except during on-site construction, in compliance with a valid Building Permit. 2. Parking. Parking is allowable within a required setback only in compliance with Section 17.46.020 Basic Requirements for Off-Street Parking and Loading) or as regulated by an adopted Specific Plan in Article 3 (Specific Plans). 3. Front and corner side setback pavement in residential zones. Within a residential zoning district, no portion of any front or corner side setback area between the street property line and the building line shall be paved unless paving has been approved by the Zoning Administrator and the paving and site comply with the following requirements: a. Not more than 30 percent of the front or corner side setback area shall be paved; b. All unpaved areas shall be improved and maintained with landscaping; c. A driveway shall lead to covered parking elsewhere on the lot; and d. Driveway widths shall not exceed the maximum allowed under Section 17.46.150 (Driveway Design, Widths, and Clearances).

(Ord. No. 7435, § 16, 10-28-2024; Ord. No. 7388, § 2(Exh. 1), 3-21-2022; Ord. 7179 § 6, 2009; Ord. 7099 § 22, 23 (Exh. 20), 2007; Ord. 7057 § 14 (a—c), 2006; Ord. 7038, §§ 8(a, b), 9, 10, 2006; Ord. 7035, §§ 10—12, 2006)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.