Omaha Municipal Code § 49-1430 Building sanitary sewer four-inch and six-inch.
Sec. 49-1430. - Building sanitary sewer four-inch and six-inch.
The following provisions shall be observed regarding building sewer cleanouts:
(a) Shall be installed at intervals not exceeding 150 feet developed length.
(b) Approved manholes may be installed in lieu of cleanouts. The maximum distance between manholes shall not exceed 300 feet.
(c) Each change of direction in the horizontal plane exceeding 45 degrees shall be served by a cleanout. (Any combination of fittings installed closer than three feet center-to-center shall be counted as the aggregate total degrees of those fittings.)
(d) Each cleanout shall open in the same direction with the flow or at right angles to, and, except in the case of wye branch and end-of-line cleanouts, vertically above the flow of the pipe.
(Ord. No. 40524, § 1, 10-20-15)