§ 6-308 — SEWER SYSTEM CONSTRUCTION
Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 6-308
Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/27e14a61-5413-4636-a2f6-fe120f5cce89
SEC. 6-308. - SEWER SYSTEM CONSTRUCTION.
(a) Any person desiring to make an addition to the city sewer system to serve property shall make a request in writing to the Director for preliminary investigation into the feasibility of such addition. If the addition as requested is found to be feasible by the Director, such addition may be made to the city sewer system in accordance with the provisions of this chapter. The Director shall cause the installation to be inspected, and shall allow the final connection to such system only if it is found that such additions conform in all respects with the standard specifications for sewer facilities of the city, with applicable health laws, and with the lines and grades designated by the Director. (b) If a right-of-way is needed for an addition to the city sewer system, the person constructing the addition shall obtain such right-of-way for the city, or pay the cost to the city of acquiring such right-of-way. (c) If the Director determines that a pump station is necessary to serve the property of the person installing the city sewer main, such person shall install a pump station meeting specifications approved by the Director and shall pay the full cost of such installation. (d) When new, enlarged or additional sewer service is required to serve a property, city sewer mains shall be installed across the full frontages of the property unless the Director determines that city sewer mains are not required at that time across the full frontage to serve other properties or because an undeveloped portion of the subject property does not require sewer service. Where a property has more than one frontage on which city sewer main installation would be required by this subsection, the Director may require payment of Lateral Sewer Charges in lieu of city sewer main installation along such additional frontages. Lateral Sewer Charges collected pursuant to this subsection shall be deemed as reimbursable pursuant to subsection 6-306(b)(3). (e) Specifications and plans for the installation of additions to the city sewer system shall be prepared by a registered civil engineer and shall be approved by the Director before a permit for doing the work may be issued. (f) When a city sewer main has been installed in public streets or easements pursuant to the regulations of the city and has been accepted by the Director, then the sewer main shall become the property of the city and a part of the city sewer system. House branch sewers, including their connection to city sewer mains, shall not be considered as city property or become a part of the city sewer system, and their maintenance and repair shall not be provided by the city. (g) In the designated area of the city that requires the installation of house sewer traps, they shall be installed as follows: (1) Each house branch sewer shall have a trap as required under Chapter 11, Article 1 of this Code. The trap shall be in the parkway or as near as possible to the property line. (2) A fresh air inlet, not fewer than four inches in diameter, shall be installed on the house side of each such trap. Each such inlet shall be fitted with an approved cap, which will prevent the depositing of any foreign matter to the inlet. (3) All fresh air inlets on public right of way shall be installed flush with adjacent ground. Ground adjacent to all fresh air inlets shall be graded so that surface water will not enter the inlet. The fresh air inlet shall be located between the curb and the sidewalk, unless approved otherwise by the Director of Development. (4) Where there is no definite drainage pattern to the yard area, any fresh air inlet on private property shall extend a minimum of six inches above the adjacent ground. Where practical, the fresh air inlet shall terminate below the floor level of the building being serviced. Where it is not practical to do so, an approved backwater valve shall be installed. This device shall be installed as required under Chapter 11, Article I of this Code, except when a backwater valve is installed in a building sewer, the main house branch trap may be omitted and a combination wye and ⅛ bend or a two-way clean-out fitting shall be installed on the building side of the backwater device. A full size vent shall be installed into the fitting and shall extend to the surface of the ground and terminate with a vent cap which meets the requirements. (5) Notwithstanding the provisions of Section 6-323 in this article, the enforcement of this subsection shall be the responsibility of the Director of Development. (h) The person constructing an addition to the city sewer system shall reimburse the city for its cost of labor (including overhead), equipment and materials for the following: (1) Construction or revision of house branches where the Director determines that the site conditions are such that there is a significant hazard to the public convenience, safety and health or to private property in the area, and that such hazard may be mitigated if the city makes arrangements for construction or revision. (2) All connections to pressure sewers after completion of such sewers. (3) Review and approval of specifications and plans submitted by the applicant for the proposed additions to the city sewer system. (4) Preliminary investigation of the feasibility of additions to the city sewer system. (5) Any design, surveying, inspection or testing performed by the city in connection with an addition to the city sewer system. Such reimbursements may be made at standard rates to cover costs as may be designated by the Council from time to time in the Master Fee Resolution. (i) Although it is the intent of this article that arrangements necessary to install city sewer mains required to serve property shall be the responsibility of the person desiring such service, an exception is necessary to facilitate minor additions to the city sewer system. The city may, upon written request of the applicant, take all steps necessary to complete the total installation subject to the following conditions: (1) Total of front footage for which Lateral Sewer Charges would be payable if city sewer mains existed plus off-site sewer required is three hundred feet or less. (2) Applicant pays the Oversize Sewer Charge, the Lateral Sewer Charge, the Wastewater Facilities Charge, and the Trunk Sewer Charge if applicable for the property as though city sewer mains already existed on the property frontage. (3) Applicant reimburses the city in accordance with this article for the house branch and preliminary investigation. (4) Applicant pays to the city the fee designated in the Master Fee Resolution for each foot of city sewer main installed to cover the cost of design, surveying, inspection, and testing. (j) Connections to city sewer mains in other than dedicated and surfaced streets or alleys shall not be permitted where service can be rendered from dedicated and surfaced streets or alleys by extension or otherwise.
(Orig. Ord. 4726; 5309, 1958; 5311, 1958; Am. Ord. 5777, 1960; Am. Ord. 6261, 1963; Am. Ord. 6667, 1965; Am. Ord. 6882, 1966; Am. Ord. 69-41, 1969; Am. Ord. 72-136, 1972; Am. Ord. 75-11, §§ 2, 3, eff. 4-1-75; Am. Ord. 75-69, § 8, eff. 7-27-75; Am. Ord. 75-96, § 2, 10-19-75; Am. Ord. 80-115, §§ 102, 103, eff. 8-8-80; Am. Ord. 98-97, §§ 14, 15, 1-9-99)
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.