Sec. 56-201. - Definitions.
(a) Words, phrases and terms defined herein shall be given the defined meaning.
(b) Words, phrases and terms not defined herein, but defined in the building code or the zoning code of the city, shall be construed as defined in such code.
(c) Words, phrases and terms neither defined herein nor in the building code or the zoning code of the city, shall be given usual and customary meanings except where the context clearly indicates a different meaning.
(d) The word "shall" is mandatory and not permissive; the word "may" is permissive and not mandatory.
Accessory structure: Also known as "appurtenant structure." A structure which is on the same parcel of property as the principal structure and the use of which is incidental to the use of the principal structure.
Addition: Any activity that expands an existing structure either horizontally or vertically. See "lateral addition" and "vertical addition."
Appeal: A request for a review of the interpretation of any provisions of this article.
Appurtenant structure: See "accessory structure."
Area of shallow flooding: A designated AO, AH, AR/AO, AR/AH or VO zone on the Flood Insurance Rate Map (FIRM) where the base flood depths range from one (1) to three (3) feet, a clearly defined channel does not exist, the path of flooding is unpredictable and indeterminate, and velocity flow may be evident. Such flooding is characterized by ponding or sheet flow.
Base flood: Also known as "one-hundred-year flood," "one-percent-annual-chance flood," and "one-percent-chance flood." A flood having a one-percent chance of being equaled or exceeded in any given year. The term does not imply that the flood will necessarily happen once every one hundred (100) years.
Base flood elevation (BFE): The elevation shown on a FEMA Flood Insurance Rate Map (FIRM) for Zones AE, AH, A1-A30, AR, AR/AE, AR/A1-A30, AR/AH, AR/AO, V1-V30, and VE that indicates the water surface elevation resulting from the occurrence of the base flood.
Basement: Any area of a building having its floor sub-grade (below ground level) on all sides.
Building: See "structure."
Channel: The physical confine of stream or waterway consisting of a bed and stream banks, existing in a variety of geometries.
Channelization: The artificial creation, enlargement or realignment of a stream channel.
Code of Federal Regulation (CFR): The codification of the general and permanent Rules published in the Federal Register by the executive departments and agencies of the Federal Government. It is divided into fifty (50) titles that represent broad areas subject to federal regulation.
Community: Any political subdivision that has the authority to adopt and enforce floodplain management regulations through zoning, including, but not limited to, counties, cities, towns, unincorporated areas, Indian tribes, and drainage and flood control districts.
Conditional letter of map revision (CLOMR): FEMA's comment on a proposed project, which does not revise an effective floodplain map, that would, upon construction, affect the hydrologic or hydraulic characteristics of a flooding source and thus result in the modification of the existing regulatory floodplain.
Crawlspace: A shallow space beneath the ground floor of a structure with clearances less than human height, generally used for storage or to access plumbing, wiring, etc. A crawlspace cannot be used as living space. A crawlspace may be considered a basement for flood insurance purposes.
Critical facility: A structure or related infrastructure, but not the land on which it is situated, that if flooded may result in significant hazards to public health and safety or interrupt essential services and operations for the community at any time before, during and after a flood. The classification and definition of critical facilities shall be as specified in Rule 6 of the Department of Natural Resources. Colorado Water Conservation Board's "Rules and Regulations for Regulatory Floodplains in Colorado," dated November 17, 2010, or as amended.
Development: Any manmade change to improved or unimproved real estate, including, but not limited to, buildings or other structures, mining, dredging, filling, grading, paving, excavation, drilling operations, or storage of equipment or materials.
DFIRM database: Database (usually spreadsheets) containing data and analyses that accompany the DFIRM. The FEMA Mapping Specifications and Guidelines outline requirements for the development and maintenance of DFIRM databases.
Digital Flood Insurance Rate Map (DFIRM): FEMA digital floodplain map. These maps serve as regulatory floodplain maps for insurance and floodplain management purposes.
Dry floodproofing: Method of floodproofing in which the intent is to keep the interior of the structure or property, including all machinery and equipment, watertight using walls that are substantially impermeable to the passage of water with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. This includes using flood damage-resistant materials and backwater prevention for storm and sanitary sewers.
Elevated building: A non-basement building which has the top of the lowest elevated floor raised above ground level by foundation walls, shear walls, posts, piers, piles, or columns. In Zones A1-A30, AE, A, A99, AO, AH, B, C, X, and D, it also includes a building elevated by means of fill or solid foundation perimeter walls with openings sufficient to facilitate the unimpeded movement of floodwaters.
Existing manufactured home park or subdivision: A manufactured home park or subdivision for which the construction of facilities for servicing the lots on which the manufactured homes are to be affixed (including, at a minimum, the installation of utilities, the construction of streets, and either final site grading or the pouring of concrete pads) is completed before the effective date of the floodplain management regulations adopted by a community.
Expansion to an existing manufactured home park or subdivision: The preparation of additional sites by the construction of facilities for servicing the lots on which the manufactured homes are to be affixed (including the installation of utilities, the construction of streets, and either final site grading or the pouring of concrete pads).
Federal Register: The official daily publication for rules, proposed rules, and notices of federal agencies and organizations, as well as executive orders and other presidential documents.
FEMA: Federal Emergency Management Agency, the agency responsible for administering the National Flood Insurance Program (NFIP).
Flood or flooding: A general and temporary condition of partial or complete inundation of normally dry land areas from:
1. The overflow of water from channels and reservoir spillways;
2. The unusual and rapid accumulation or runoff of surface waters from any source; or
3. Mudslides or mudflows that occur from excess surface water that is combined with mud or other debris that is sufficiently fluid so as to flow over the surface of normally dry land areas (such as earth carried by a current of water and deposited along the path of the current).
Flood damage-resistant materials: Any building product (material, component or system) capable of withstanding direct and prolonged contact with floodwaters without sustaining significant damage. Flood damage-resistant materials must comply with FEMA Technical Bulletin 2 "Flood Damage-Resistant Materials Requirements," dated August 2008, or as amended.
Flood fringe: The portion of land in Zone AE of the regulatory floodplain which is located outside of the designated floodway for a specific waterway.
Flood hazard zones: Areas designated by FEMA on the FIRM and/or LOMRs that correspond to differing types and levels of flood risk. These zones include, but are not limited to: A, A1-A30, AE, AH, AO, AR, AR/A1-A30, AR/AE, AR/AH, AR/AO, A99, B, C, D, E, M, V, V1-V30, VE, VO, X (shaded) and X (unshaded). The definitions of each zone are as indicated on the associated FIRM.
Flood Insurance Rate Map (FIRM): The official map on which FEMA has delineated both the Special Flood Hazard Areas (SFHA) and the risk premium zones applicable to the community.
Flood Insurance Study (FIS): The official report provided by FEMA which contains the Flood Insurance Rate Map (FIRM), floodway data tables, and flood profiles for studied flooding sources. This information can be used to determine base flood elevations (BFEs) for some areas.
Floodplain: Any land area susceptible to being inundated as the result of a flood.
Floodplain administrator: The community official designated to administer and enforce the floodplain management regulations and other appropriate sections of Title 44 of the Code of Federal Regulations pertaining to floodplain management.
Flood profile: A graph or longitudinal profile showing the relationship of the water surface elevation of a flood event to a location along a waterway.
Floodproofing: Any combination of structural and/or non-structural provisions, additions, changes, or adjustments to properties and structures subject to flooding primarily for the reduction or elimination of flood damages to properties, water and sanitary facilities, structures, machinery and equipment, and contents of buildings. The two (2) types of floodproofing are "wet floodproofing" and "dry floodproofing."
Flood protection elevation (FPE): The elevation of freeboard plus the base flood elevation (BFE), or in an AO Zone freeboard plus depth of flooding (two-foot depth if no number specified) above the highest adjacent grade (HAG).
Flood storage area: The flood fringe and areas of shallow flooding portion of the regulatory floodplain in which flows are characteristically of shallow depths and low velocities.
Floodway: The channel of a river or other watercourse and the adjacent land areas that must be reserved in order to discharge the base flood without cumulatively increasing the water surface elevation more than a designated height. The designated height for all newly studied reaches shall be one-half (0.5) foot. A letter of map revision (LOMR) to an existing floodway designation may continue to use the floodway criteria at the time of the existing floodway designation, at the discretion of the floodplain administrator. Existing one-foot floodway designations may be used until revised on the regulatory floodplain map.
Freeboard: The vertical distance in feet above a predicted water surface elevation intended to provide a margin of safety to compensate for unknown factors that could contribute to flood heights greater than the height calculated for a selected size flood such as debris blockage and increased runoff due to urbanization of the watershed. For purposes of this ordinance, freeboard is measured above the BFE, or above the depth of flooding in AO Zones, defined for the regulatory floodplain.
Highest adjacent grade (HAG): The highest natural elevation of the ground surface prior to construction next to the proposed walls of a structure.
Historic structure: Any structure that is:
1. Listed individually in the National Register of Historic Places (a listing maintained by the Department of Interior) or preliminarily determined by the Secretary of the Interior as meeting the requirements for individual listing on the National Register;
2. Certified or preliminarily determined by the Secretary of the Interior as contributing to the historical significance of a registered historic district or a district preliminarily determined by the Secretary to qualify as a registered historic district;
3. Individually listed on a state inventory of historic places in states with historic preservation programs which have been approved by the Secretary of Interior; or
4. Individually listed on a local inventory of historic places in communities with historic preservation programs that have been certified either:
a. By an approved state program as determined by the Secretary of the Interior; or
b. Directly by the Secretary of the Interior in states without approved programs.
Lateral addition: An addition which is horizontal in nature and increases the footprint of the existing structure.
Letter of map revision (LOMR): FEMA's official revision of an effective Flood Insurance Rate Map (FIRM), LOMRs are generally based on the implementation of physical measures that affect the hydrologic or hydraulic characteristics of a flooding source and thus result in the modification of the existing regulatory floodway, the effective base flood elevations (BFEs), or the special flood hazard area (SFHA).
Letter of map revision based on fill (LOMR-F): FEMA's modification of the special flood hazard area (SFHA) shown on the Flood Insurance Rate Map (FIRM) based on the placement of fill outside the existing regulatory floodway.
Levee: A manmade structure, usually earthen, embankment, designed and constructed in accordance with sound engineering practices to contain, control, or divert the flow of water so as to provide protection from temporary flooding. For a levee structure to be reflected on the FEMA Flood Insurance Rate Map (FIRM) as providing flood protection, the levee structure must meet the requirements set forth in Section 65.10 of the National Flood Insurance Program (NFIP) regulations.
Levee system: A flood protection system which consists of a levee, or levees, and associated structures, such as closure and drainage devices, which are constructed and operated in accordance with sound engineering practices.
Lowest adjacent grade (LAG): The lowest elevation of the ground surface touching a structure.
Lowest floor: The lowest floor of the lowest enclosed area (including basement). An unfinished or flood-resistant enclosure, usable solely for parking of vehicles, building access or limited storage in an area other than a basement area is not considered a building's lowest floor; provided that such enclosure is not built so as to render the structure in violation of the applicable non-elevation design requirement of Section 60.3 of the National Flood Insurance Program (NFIP) regulations.
Machinery and equipment: Utilities and mechanical items that service the building. These items include, but are not limited to, elevators and their associated equipment, transformers, electrical panels, electric meters, junction boxes, receptacles, switches, gas meters, furnaces, hot water heaters, heat pumps, air conditioners, generators, ductwork, communications equipment, and other service facilities.
Manager of transportation and infrastructure: Hereinafter called the manager, he shall be the officer in full charge and control of the department of transportation and infrastructure (refer to subsection 56-204(a)).
Manufactured home: A structure, transportable in one (1) or more sections, which is built on a permanent chassis and is designed for use with or without a permanent foundation when connected to the required utilities. The term "manufactured home" includes "mobile home" but does not include "recreational vehicle" or "modular home".
Manufactured home park or subdivision: A parcel (or contiguous parcels) of land divided into two (2) or more manufactured home lots for rent or sale.
Mean sea level: For purposes of the National Flood Insurance Program (NFIP), the North American Vertical Datum (NAVD) of 1988 or other datum, to which base flood elevations shown on a community's Flood Insurance Rate Map (FIRM) are referenced.
Mobile home: A type of manufactured home built prior to 1976 and constructed to the American National Standards Institute (ANSI) A-119.1 Standard.
Modular home: A Colorado-labeled factory-built residential structure that meets or exceeds the currently adopted building codes in Colorado. Modular housing is custom designed and can be fabricated for both single-family and multifamily use.
National Flood Insurance Program (NFIP): FEMA's program of flood insurance coverage and floodplain management administered in conjunction with the Robert T. Stafford Relief and Emergency Assistance Act. The NFIP has applicable federal regulations promulgated in Title 44 of the Code of Federal Regulations. The U.S. Congress established the NFIP in 1968 with the passage of the National Flood Insurance Act of 1968.
New construction: For the purposes of determining insurance rates, structures for which the "start of construction" commenced on or after the effective date of an initial FIRM or after December 31, 1974, whichever is later, and includes any subsequent improvements to such structures. For floodplain management purposes, "new construction" means structures for which the "start of construction" commenced on or after the effective date of a floodplain management regulation adopted by a community and includes any subsequent improvements to such structures. In Denver, the effective date of the initial FIRM is April 15, 1986, and the effective date of the first adopted floodplain management regulation is March 17, 1986.
New manufactured home park or subdivision: A manufactured home park or subdivision for which the construction of facilities for servicing the lots on which the manufactured homes are to be affixed (including at a minimum, the installation of utilities, the construction of streets, and either final site grading or the pouring of concrete pads) is completed on or after the effective date of floodplain management regulations adopted by a community. In Denver, the effective date of the first adopted floodplain management regulation is March 17, 1986.
No-rise certification: A record of the results of an engineering analysis conducted to determine whether a project will increase flood heights in a floodway. A no-rise certification must be supported by technical data and signed by a licensed Colorado Professional Engineer. The supporting technical data should be based on the standard step-backwater computer model used to develop the floodway shown on the Flood Insurance Rate Map (FIRM).
Obstruction: Any material or item that may impact the flow or storage of floodwaters. This includes, but is not limited to, fill, structures, bridges, roadways, equipment, walls, and fences.
Occupancy: The use or possession of a building by humans for purposes including, but not limited to, residential, office, hospital, or commercial.
One-hundred-year flood: See "base flood."
One-percent-annual-chance flood or one-percent-chance flood: See "base flood."
Phased improvement: Any improvement to a structure that occurs within one (1) year of permit closeout of any previous construction on that structure. Phased improvements may be intentional or unintentional. Examples of phased improvement include, but are not limited to, incomplete work, multiple permits, consecutive permits, modification of existing permits, and unauthorized work. Changes in ownership do not preclude previous improvements. This applies to the entire structure as a whole, including multi-tenant and multi-unit structures.
Recreational vehicle (RV): Means a vehicle which is:
1. Built on a single chassis:
2. Four hundred (400) square feet or less when measured at the largest horizontal projection:
3. Designed to be self-propelled or permanently towable by a light duty truck; and
4. Designed primarily not for use as a permanent dwelling but as temporary living quarters for recreational, camping, travel, or seasonal use.
Regulatory floodplain: The area of land subject to inundation by the base flood as delineated by the special flood hazard area (SFHA), any other floodplain maps that have been adopted by the manager of transportation and infrastructure, and areas that have been removed from the SFHA by a FEMA issued letter of map revision based on fill (LOMR-F).
Regulatory floodway: See "floodway."
Special flood hazard area (SFHA): The land within a community subject to inundation by the base flood as shown on the Flood Insurance Rate Map (FIRM).
Start of construction: The date the building permit was issued, including substantial improvement, provided, the actual start of construction, repair, reconstruction, rehabilitation, addition, placement, or other improvement was within one hundred eighty (180) days of the permit date. The actual start means either the first placement of permanent construction of a structure on a site, such as the pouring of slab or footings, the installation of piles, the construction of columns, or any work beyond the stage of excavation: or the placement of a manufactured home on a foundation. Permanent construction does not include land preparation, such as clearing, grading and filling; nor does it include the installation of streets and/or walkways: nor does it include excavation for basement, footings, piers or foundations or the erection of temporary forms: nor does it include the installation on the property of accessory buildings, such as garages or sheds not occupied as dwelling units or not part of the main structure. For a substantial improvement, the actual start of construction means the first alteration of any wall, ceiling, floor, or other structural part of a building, whether or not that alteration affects the external dimensions of the building.
Structure: A walled and roofed building, including a gas or liquid storage tank, which is principally above ground, as well as a manufactured home.
Substantial damage: Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed fifty (50) percent of the market value of the structure just prior to when the damage occurred.
Substantial improvement: Any reconstruction, rehabilitation, addition, or other improvement of a structure, the cost of which equals or exceeds fifty (50) percent of the market value of the structure before "start of construction" of the improvement. The value of the structure shall be determined by the local jurisdiction having land use authority in the area of interest. This includes structures which have incurred "substantial damage", regardless of the actual repair work performed. "Phased improvements" are calculated cumulatively towards the cost of improvement. The term "substantial improvement" does not, however, include either:
1. Any project for improvement of a structure to correct existing violations of state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary conditions, or
2. Any alteration of a "historic structure" provided that the alteration will not preclude the structure's continued designation as a "historic structure."
Use: The purpose for which land or structures thereon is designed, arranged or intended to be occupied or used, or for which it is occupied, maintained, rented or leased.
Variance: A grant of relief from the requirements of this article, when specific enforcement would result in unnecessary hardship (hardship that is solely financial is not grounds for a variance). A variance, therefore, permits construction or development in a manner otherwise prohibited by this article.
Vertical addition: An addition which is vertical in nature, but does not increase the horizontal footprint of the existing structure.
Violation: The failure of a structure or other development to be fully compliant with the community's floodplain management regulations. A structure or other development without the elevation certificate, other certifications, or other evidence of compliance required in National Flood Insurance Program (NFIP) regulations Section 60.3(b)(5), (c)(4), (c)(10), (d)(3), (e)(2), (e)(4), or (e)(5) is presumed to be in violation until such time as that documentation is provided.
Water surface elevation (WSEL): The height, in relation to the North American Vertical Datum (NAVD) of 1988 (or other datum where specified), of floods of various magnitudes and frequencies.
Wet floodproofing: A method of floodproofing to reduce flood damage that typically involves three (3) elements: allowing floodwaters to enter and exit to minimize structural damage, using flood damage-resistant materials, and elevating machinery and equipment. Wet floodproofing cannot be used in lieu of elevation or dry floodproofing requirements.
Zones: See "Flood hazard zones."
(Ord. No. 158-86, § 1, 3-17-86; Ord. No. 547-13, § 2, 11-4-13; Ord. No. 39-20, § 259, 2-3-20)