Backwater valves and gate valves installed in building drain or building sewers.
Omaha Municipal Code § 49-804
in effectSec. 49-804. - Backwater valves and gate valves installed in building drain or building sewers.
The following provisions shall apply to backwater valves and gate valves:
(a) Backwater valves shall have cast-iron bodies with bearing parts of noncorrosive metal or material.
(b) Backwater valves shall be constructed to ensure a positive mechanical seal and remain closed except when discharging wastes.
(c) Valve access covers shall be bolted-type with a gasket.
(d) Drainage service valves shall be full-way type with working parts of noncorrosive metal.
(e) Four-inch or greater diameter valves shall have cast-iron or brass bodies.
(f) When installed below a finished floor and less than two feet deep, the minimum access opening shall be 24 inches by 24 inches.
(g) When installed outside the building or more than two feet deep a minimum 48-inch manhole shall be used. Exception: Backwater valves for dwelling units and townhouses may be PVC or ABS plastic, but shall not be co-mingled with other materials.
(Ord. No. 40524, § 1, 10-20-15)