For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-653 — Floodways

Code of Ordinances of the City of Montgomery, Alabama (Supp. No. 27: codified through Ordinance No. 4-2026, enacted March 5, 2026) · Montgomery City Code § 5-653

Corpus is an independent public-information project, not the official City of Montgomery website. Stable reference: corpuslaw.us/code/3b9a1ca7-377c-468d-9201-99e1a28db92b

Sec. 5-653. - Floodways.

Located within special flood hazard areas established in division 2, section 5-617, are areas designated as floodway. A floodway may be an extremely hazardous area due to velocity floodwaters, debris or erosion potential. In addition, the area must remain free of encroachment in order to allow for the discharge of the base flood without increased flood heights. Therefore, the following provisions shall apply: (1) The community shall select and adopt a regulatory floodway based on the principle that the area chosen for the regulatory floodway must be designed to carry the waters of the base flood, without increasing the water surface elevation of that flood more than one foot at any point; (2) Encroachments, including fill, new construction, substantial improvements or other development are prohibited within the adopted regulatory floodway unless it is demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in BFEs during the occurrence of the base flood discharge. A registered professional engineer must provide supporting technical data and certification (no-rise certificate) to the floodplain administrator for the proposed floodway encroachment. The no-rise certificate must be submitted to the floodplain administrator with the development permit (including a site plan showing the current and proposed flood way alignment) for approval. (3) Foundation design and structural stability. All new construction or substantial improvement of structures permitted within the regulatory floodway, in accordance with subsection (2), shall include a foundation design prepared, signed, and sealed by a registered professional engineer licensed in the State of Alabama. a. The structure is designed and anchored to resist flotation, collapse, and lateral movement resulting from hydrodynamic and hydrostatic forces, including the effects of buoyancy and flood-borne debris; b. The foundation system and supporting structural components are capable of withstanding expected flood velocities, scour, and erosion potential associated with the base flood conditions at the site according to division 3, subsection 5-638(8); c. The design complies with the applicable standards of ASCE 24, flood resistant design and construction, as referenced by FEMA and adopted by the community; and d. The foundation plans and calculations are submitted to the floodplain administrator as part of the floodplain development permit application for review and approval. (4) Only if division 4, section 5-653, provisions (1) and (2) are satisfied, then any new construction or substantial improvement in a floodway shall comply with all other applicable flood hazard reduction provisions of division 4. After satisfying the required provisions stated in this section, encroachments in floodways should be limited to the following types of projects: a. Road improvements and repairs; b. Utility easements/rights-of-way; c. Public improvements or public structures for bridging over the floodway; and (5) Fencing shall be prohibited in floodways unless it is demonstrated that such development will not cause any increase in the BFE. Appropriate analysis and documentation shall be submitted along with the development permit for review and approval. Fences that have the potential to block or restrict the passage of floodwaters (by trapping debris or with openings too small to allow unhindered passage of water), such as stockade and wire mesh fences, shall meet the requirements of division 4, subsection 5-653(2). (6) Variances shall not be issued within any designated floodway for new residential structures. Variances for non-residential structures may only be considered if the applicant demonstrates, through hydrologic and hydraulic analysis performed by a registered professional engineer, that the encroachment will not cause any increase in BFE's during the occurrence of the base flood discharge, and the structure otherwise complies with the requirements of this article.

(Ord. No. 4-2026, 3-5-2026)

Ask a question about Montgomery law

Corpus searches the Montgomery sections it holds and shows the ones that match, with their citations. Free, no sign-in.