§ 21-217 — Drainage standards—Generally

Code of Ordinances of the City of Tuscaloosa, Alabama (Codified through Ordinance No. 9809, enacted August 25, 2026 (Supp. No. 103, Update 1)) · Tuscaloosa Code of Ordinances § 21-217

Corpus is an independent public-information project, not the official City of Tuscaloosa website. Stable reference: corpuslaw.us/code/40ba9345-18a9-47f5-afcc-15c33b177f52

Sec. 21-217. - Drainage standards—Generally.

Without limiting the generality of a land development plan (plan) as herein defined, such a plan submitted in support of a permit application shall also consist of text statements, engineering drawings, contour maps and supporting engineering calculations, as applicable to the property covered by the plan, which are necessary to demonstrate full compliance with the requirements of these drainage standards. A plan shall include all pertinent information required by the city engineer and shall include, but is not limited to, the following elements: (a) An engineering hydrologic analysis of stormwater runoff under existing site conditions and under proposed developed site conditions prepared by a professional engineer with expertise in hydrology. (b) A detailed evaluation of the projected effects on public and private property adjoining the site and on existing drainage facilities and systems both on and off the site; including evaluation of increased runoff of stormwater caused by the development or earth change. (c) Topographic information shall extend a minimum of two hundred (200) feet beyond the property line. Topographic information from the outfall of any piped or ditched (natural or manmade) area shall extend downstream to the nearest drainage structure through which the water flows. (d) The location of all existing drainage channels and subsurface drainage structures. (e) The on-site regulatory flood elevations and the boundaries of any floodplain area. (f) Drainage facilities on property lying downstream of other developable vacant land shall be sized to accommodate the pass through of the twenty-five-year postdeveloped or one-hundred-year predeveloped flow, whichever is greater. It shall be assumed that the vacant property will be developed at a similar density of the proposed development. (g) Proposed fill or other structure elevating techniques, levees, channel modifications and detention facilities; (h) The location and size of all existing and proposed drainage easements and areas; (i) Any computer software that is used must be approved by the city engineer prior to submitting a hydrologic study. If a computer program is not used to determine stormwater runoff, the rational method shall be used. (j) A minimum design storm of twenty-five (25) years must be used for all computations (excepting detention facilities and spillways). (k) Evidence that application for NPDES permit has been filed, where applicable, must be presented before a permit will be issued. (l) The minimum pipe size shall be fifteen (15) inches and in accordance with the specifications set out below. (m) Delineating and/or blue-lined streams as depicted on the USGS topographic maps. (n) The location of all public utilities and public utility easements on the site and adjacent to the site and an evaluation of what measures will be taken to insure that the integrity, access, maintenance and usability of the utilities and easements by the public utility itself will be preserved.

(Ord. No. 7075, § 2, 5-22-07)

Ask a question about Tuscaloosa law

Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.